Page 10 of 16 Page 11 of 16 Page 12 of 16
Page 13 of 16 Page 14 of 16 Page 15 of 16 Page 16 of 16
Page 9 of 16
UK Head-Oce
AIRFLOW DEVELOPMENTS Limited
Aidelle House, Lancaster Road
Cressex Business Park
High Wycombe
Buckinghamshire
HP12 3QP
United Kingdom
Tel: +44 (0) 1494 525252
Fax : +44 (0) 1494 461073
Email: info@airow.com
Web: airow.com
Czech Republic
AIRFLOW LUFTTECHNIK GmbH
organizační složka Praha
Hostýnská 520
108 00 Praha 10
Czech Republic
Tel: +42 (0) 2 7477 2230
Fax: +42 (0) 2 7477 2370
Email: info@airow.cz
Web: airow.cz
Germany
AIRFLOW LUFTTECHNIK GmbH
Posach 1208
D-53349 Rheinbach
Germany
Tel: +49 (0) 222 69205 0
Fax: +49 (0) 222 69205 11
Email: info@airow.de
Web: airow.de
Warranty
Applicable to units installed and used in the United
Kingdom. Airow Developments Ltd guarantees the Aventa
in-line for 3 YEARS from date of purchase against faulty
material or workmanship. Warranty only covers the fan,
not the reinstallaon of this if required. In the event of any
defecve parts being found, Airow Developments Ltd
reserve the right to repair or at our discreon replace
without charge provided that the unit:
1. Has been installed and used in accordance with the
ng and wiring instrucons supplied with each unit.
2. Has not been connected to an unsuitable electrical
supply.
3. Has not been subjected to misuse, neglect or damage.
4. Has not been modied or repaired by any person not
authorised by Airow Developments Ltd
5. Has been installed in accordance with latest Building
Regulaons and IEEE wiring regulaons by a recognised
competent installer.
Airow Developments Ltd shall not be liable for any loss,
injury or other consequenal damage, in the event of a
failure of the equipment or arising from, or in connecon
with, the equipment excepng only that nothing in this
condion shall be construed as to exclude or restrict
liability for negligence.
This warranty does not in any way aect any statutory or
other consumer rights.
Maintenance
SAFETY FIRST: ALWAYS ISOLATE THE FAN UNIT FROM THE
POWER SUPPLY BEFORE REMOVING THE COVER.
When installed according to these instrucons the Aventa
in-line range is completely safe. The materials used do not
constute a hazard.
Cleaning
The external housing of the fan can be wiped with a damp
cloth. Do not use household cleaners containing abrasives.
Note: Always isolate the fan when cleaning. Never clean
any parts of the fan assembly by immersing in water or
using a dishwasher.
Warning
This appliance can be used by children aged from 8 years
and above and persons with reduced physical, sensory or
mental capabilies or lack of experience and knowledge if
they have been given supervision or instrucon concerning
use of the appliance in a safe way and understand the
hazards involved. Children shall not play with the
appliance. Cleaning and user maintenance shall not be
made by children without supervision.
Recommended Best Pracce
The Building Regulaons 2010, Statutory Instrument Part
9, paragraph 42, imposes a requirement that tesng and
reporng of mechanical venlaon performance is
conducted in accordance with an approved procedure.
Compliance with this requirement by an assessed and
registered ‘Competent Person’ should follow a ‘Best
Pracce’ process and adopt air ow measurement,
Method A – The Uncondional Method – using a suitable
UKAS cered measuring instrument. Generically referred
to as a ‘Zero Pressure Air Flow Meter’ or ‘Powered Flow
Meter’.
Further informaon on this method is detailed in NHBC
Building Regulaons Guidance Note G272a 10/13 and
BSRIA ‘A Guide to Measuring air ow rates’ document
BG46/2015
Installaon with exible ducng
Where exible ducng is used the diameter must be
maintained with the minimum radius of a bend equal to the
diameter of the ducng. It is good venlaon pracce that
the ducng is extended to 90% of its possible length in
order to maintain the best possible airow. Ensure that
exible duct connecons are not over ghtened to the fan
outlet spigot. To maximise airow rigid ducng should be
used where possible. The fan and ducng should be
installed in accordance with the requirements of the
Domesc Venlaon Compliance Guide, part of the
Building Regulaons.
Fan adjustment—Timer
The fan with mer funcon switches on when the voltage
is supplied to the LT or L1 terminal via an external switch.
Aer the voltage to the LT or L1 terminal is disconnected
the fan connues to run for the set overrun period,
between 1 and 20 minutes. The mer overrun is factory
set to 15 mins, it is adjusted by turning the potenometer
(T) clockwise to increase and an-clockwise to decrease.