Airflow Susurro 400 User manual

Instruction Manual
Mechanical Ventilation with Heat Recovery
INSTRUCTION MANUAL
Susurr
TM

BEFORE STARTING
2
INSTRUCTION MANUAL
Susurr
TM
80000749Issue 1 08/17
The following symbols in the manual serve for better guidance. The following table describes the symbols and their meaning.
Before installing the unit, read carefully the section on the safe operation of the heat recovery unit. You will nd
instructions on the safe and proper use of the product.
Symbol Meaning
ATTENTION!
PLEASE NOTE!
YOU WILL NEED
TECHNICAL INFORMATION
Warning or Caution
Important instructions
Practical tips and information
Reference to a different part of the manual
Detailed technical information
This manual provides instructions on how to properly install the unit. Before installing the unit, read carefully the entire
manual. The manufacturer reserves the right to make changes, including in the technical documentation, without prior
notice. Keep the manual in a safe place for future reference. The manual is an integral part of the product.

UNPACKING
3
© Airow - All rights reserved
INSTRUCTION MANUAL
Susurr
TM
PLEASE NOTE!
• If the unit was shipped at below 0°C temperatures, let it rest
for at least 2 hours, without turning it on, so that its inner
temperature can match the surroundings.
PLEASE CHECK THE DELIVERED PRODUCT
PLEASE NOTE!
• Unpack the product upon delivery and control for damages. In
case of damage, inform and le a report with the carrier.
• Any claims that have not been led in due time, will be
disregarded later.
• Check that you have received the model ordered. Should the
delivered model differ from the one ordered, do not unpack the
unit and notify the supplier immediately.
• After unpacking, check that the unit and the accessories are in
good order. Contact the supplier in case of any doubt.
• Do not attempt to commission a damaged ventilation unit.
• If the unit is not unpacked upon delivery, it must be stored in a
dry room with a temperature range of +5 °C to +40 °C.
• This product must not be used by persons (incl. minors) with
mental or physical disabilities, or insufcient experience or
knowledge in the safe use thereof, unless they are supervised
or instructed on how to use the product by a person responsible
for their safety.
• Do no let children play with the unit.
UNPACKING THE UNIT
+5 oC
+40 oC
All the packing material is environmentally
friendly and can be reused or recycled.
Please, contribute actively to the protection
of the environment and procure the regular
disposal or recycling of packing materials.
Susurro
1X
1X
1X

MAIN PART
4
INSTRUCTION MANUAL
Susurr
TM
Fan / Ventilator
Heat exchanger / Wärmetauscher
Filter / Filter
Regulation / die Regulation
Condesate exhaust / Kondensatausscheidung
Afterheater / Nachheizeinrichtung / DX / CO
By-pass ap / By-pass Klappe
Preheater / Vorwärmer
Operational diagram
Funktionsschema
Fan / Ventilator
Heat exchanger / Wärmetauscher
Filter / Filter
Regulation / die Regulation
Condesate exhaust / Kondensatausscheidung
Afterheater / Nachheizeinrichtung / DX / CO
By-pass ap / By-pass Klappe
Preheater / Vorwärmer
Operational diagram
Funktionsschema
Fan / Ventilator
Heat exchanger / Wärmetauscher
Filter / Filter
Regulation / die Regulation
Condesate exhaust / Kondensatausscheidung
Afterheater / Nachheizeinrichtung / DX / CO
By-pass ap / By-pass Klappe
Preheater / Vorwärmer
Operational diagram
Funktionsschema
Fan / Ventilator
Heat exchanger / Wärmetauscher
Filter / Filter
Regulation / die Regulation
Condesate exhaust / Kondensatausscheidung
Afterheater / Nachheizeinrichtung / DX / CO
By-pass ap / By-pass Klappe
Preheater / Vorwärmer
Operational diagram
Funktionsschema
Fan / Ventilator
Heat exchanger / Wärmetauscher
Filter / Filter
Regulation / die Regulation
Condesate exhaust / Kondensatausscheidung
Afterheater / Nachheizeinrichtung / DX / CO
By-pass ap / By-pass Klappe
Preheater / Vorwärmer
Operational diagram
Funktionsschema
1
2
4
3
Fan / Ventilator
Heat exchanger / Wärmetauscher
Filter / Filter
Regulation / die Regulation
Condesate exhaust / Kondensatausscheidung
Afterheater / Nachheizeinrichtung / DX / CO
By-pass ap / By-pass Klappe
Preheater / Vorwärmer
Operational diagram
Funktionsschema
Fan / Ventilator
Heat exchanger / Wärmetauscher
Filter / Filter
Regulation / die Regulation
Condesate exhaust / Kondensatausscheidung
Afterheater / Nachheizeinrichtung / DX / CO
By-pass ap / By-pass Klappe
Preheater / Vorwärmer
Operational diagram
Funktionsschema
Fan / Ventilator
Heat exchanger / Wärmetauscher
Filter / Filter
Regulation / die Regulation
Condesate exhaust / Kondensatausscheidung
Afterheater / Nachheizeinrichtung / DX / CO
By-pass ap / By-pass Klappe
Preheater / Vorwärmer
Operational diagram
Funktionsschema
Fan / Ventilator
Heat exchanger / Wärmetauscher
Filter / Filter
Regulation / die Regulation
Condesate exhaust / Kondensatausscheidung
Afterheater / Nachheizeinrichtung / DX / CO
By-pass ap / By-pass Klappe
Preheater / Vorwärmer
Operational diagram
Funktionsschema
Fan / Ventilator
Heat exchanger / Wärmetauscher
Filter / Filter
Regulation / die Regulation
Condesate exhaust / Kondensatausscheidung
Afterheater / Nachheizeinrichtung / DX / CO
By-pass ap / By-pass Klappe
Preheater / Vorwärmer
Operational diagram
Funktionsschema
Fan / Ventilator
Heat exchanger / Wärmetauscher
Filter / Filter
Regulation / die Regulation
Condesate exhaust / Kondensatausscheidung
Afterheater / Nachheizeinrichtung / DX / CO
By-pass ap / By-pass Klappe
Preheater / Vorwärmer
Operational diagram
Funktionsschema
4
3
5
5
6
2
1
Exhaust grid with Straw system
2
Main power switch
3
Connection for air intake with
spring-loaded ap
4
Connection for exhaust air with
spring-loaded ap
5
Suction grid with Straw system
6
Condensate drain

SPARE PARTS
5
© Airow - All rights reserved
INSTRUCTION MANUAL
Susurr
TM
7
5
3
1
6
2
98
4
Number Description Susurro 400 Susurro 700 Susurro 1000
Part number/pc. Pcs. in
unit Part number/pc. Pcs. in
unit Part number/pc. Pcs. in
unit
Main PCB 60000397 160000397 160000397 1
PCB module for
water coil 60000398 160000398 160000398 1
Water heater 60000399 160000399 160000400 1
Electric post-
heater 60000401 160000402 160000403 1
CO2sensor 60000404 160000404 160000404 1
HR cell 60000405 160000406 160000407 1
Motor (exhaust
air) 60000408 160000408 160000409 1
Bypass actuator 60000410 160000410 160000410 1
Motor (outdoor
air) 60000408 160000408 160000409 1
Pressure sensor 60000411 360000411 360000411 3
Pre-heater 60000412 160000413 160000414 1
1
2
3
4
5
6
7
8
9
The part numbers of the spare lters can be found in “Maintenance”, replacing lters

DIMENSIONS
6
The values in the table are in millimeters (mm)
A B C D E F G H I J K L M
Susurro 400 1806 397 942 183 1408 875 689 108 503 144 250 197 1835
Susurro 700 2076 452 1098 212 1648 1006 763 167 548 146 315 228 2105
Susurro 1000 2406 573 1263 241 1920 1203 962 150 604 140 315 287 2435
STANDARD
A
F
22x2
J
I
B
C
DE
G
L
H
K
Fan / Ventilator
Heat exchanger / Wärmetauscher
Filter / Filter
Regulation / die Regulation
Condesate exhaust / Kondensatausscheidung
Afterheater / Nachheizeinrichtung / DX / CO
By-pass ap / By-pass Klappe
Preheater / Vorwärmer
Operational diagram
Funktionsschema
Fan / Ventilator
Heat exchanger / Wärmetauscher
Filter / Filter
Regulation / die Regulation
Condesate exhaust / Kondensatausscheidung
Afterheater / Nachheizeinrichtung / DX / CO
By-pass ap / By-pass Klappe
Preheater / Vorwärmer
Operational diagram
Funktionsschema
M
8
INSTRUCTION MANUAL
Susurr
TM

7
© Airow - All rights reserved
The values in the table are in millimeters (mm)
A B C D E F G H I J K L M
Susurro 400 1870 394 965 214 1408 908 689 165 535 177 246 197 1835
Susurro 700 2141 455 1116 247 1648 1039 763 185 581 224 315 228 2105
Susurro 1000 2470 575 1281 275 1920 1235 962 150 637 224 315 287 2435
DESIGN
DETAIL A
MĚŘÍTKO 2 : 1
18
13
1039
37
50 581
22X2
TR
42
97
PŘIPOJENÍ PRO VODU - 1/2"
2141
455
315
247 1648
228
173
43
224
62
1116
103
89
70
70
120
132
A
8
2105
763
185
A
F
J
I
B
C
DE
G
L
H
K
Fan / Ventilator
Heat exchanger / Wärmetauscher
Filter / Filter
Regulation / die Regulation
Condesate exhaust / Kondensatausscheidung
Afterheater / Nachheizeinrichtung / DX / CO
By-pass ap / By-pass Klappe
Preheater / Vorwärmer
Operational diagram
Funktionsschema
Fan / Ventilator
Heat exchanger / Wärmetauscher
Filter / Filter
Regulation / die Regulation
Condesate exhaust / Kondensatausscheidung
Afterheater / Nachheizeinrichtung / DX / CO
By-pass ap / By-pass Klappe
Preheater / Vorwärmer
Operational diagram
Funktionsschema
Fan / Ventilator
Heat exchanger / Wärmetauscher
Filter / Filter
Regulation / die Regulation
Condesate exhaust / Kondensatausscheidung
Afterheater / Nachheizeinrichtung / DX / CO
By-pass ap / By-pass Klappe
Preheater / Vorwärmer
Operational diagram
Funktionsschema
M 2:1
M
INSTRUCTION MANUAL
Susurr
TM

TECHNICAL PARAMETERS
INSTALLATION
8
Number of phases/Voltage [V]/Current [A]/Power consumption [W]
Type
Maximum
air ow
[m3/h
]
Intake
lter
class
Exhaust
lter
class
Frequency
[Hz]
Unit without
heaters EPRH EPOH WPOH EPRH-EPOH EPRH-WPOH Weight*
[kg]
Susurro 400 400 F7 G4 50
1 / 230 / 2.7 / 340 1 / 230 / 9.22 / 1840 1 / 230 / 9.22 / 1840 1 / 230 / 2.7 / 340
1 / 230 / 15.74 / 3340
1 / 230 / 9.22/ 1840
95
Susurro 700 700 F7 G4 50
1 / 230 / 2.7/ 340 1 / 230 / 11.4 / 2340
1 / 230 / 12.48 / 2590
1 / 230 / 2.7 / 340 3 / 400 / 9.78 / 4590 1 / 230 / 11.4 / 2340
130
Susurro 1000 1000 F7 G4 50
1 / 230 / 5.0 / 700 3 / 400 / 7.5 / 3770 3 / 400 / 9.33 / 3770 1 / 230 / 5.0 / 700
3 / 400 / 11.83 / 6770
3 / 400 / 7.5 / 3770
152
* Given weight refers to the heaviest unit for each model
EPRH - electric pre-heater
EPOH - electric post-heater
WPOH - water post-heater
CHOOSING THE PLACE
The project of the ventilation system must be prepared by a HVAC designer.
TECHNICAL INFORMATION
The unit must be operated in a closed, dry place with a range of temperatures of+5°C to +40°C.
+5°C
+40°C
The ltered air must have a temperature ranging from -15°C to +40°C and a relative humidity of up to 90%.
If air at a temperature lower than -15°C is to be sucked, the unit can work in the anti-freeze mode or may switch itself off
to prevent damages to important components.
-20 °C
+40 °C
max. 90%
15 °C
INSTRUCTION MANUAL
Susurr
TM

INSTALLATION
9
© Airow - All rights reserved
The unit is not designed to lter air containing combustible
or ammable particles, chemical fumes, coarse dust, carbon,
grease, poisons, bacteria, etc.
The IP protection level of the unit in the ducts is IP 20
(protection against objects bigger than 12.5 mm, does not
protect against water).
Installation distance
A
Susurro 400 ---
Susurro 700 min. 1500 mm
Susurro 1000 ---
B
Susurro 400 170 mm
Susurro 700 190 mm
Susurro 1000 280 mm
TECHNICAL INFORMATION
• All the models of the heat recovery unit can be installed
in the following positions:
• Any other position is forbidden.
• The unit must be installed so that the direction of the air circulation
will correspond with the air circulation in the distribution system.
• The installation must allow access for maintenance, service or
disassembling. Access relates mainly to opening the revision
lid.
Required distance
CAUTION!
The intake and exhaust vents must not be blocked by non-
combustible material.
• The safe distance between combustible materials and the
intake is 250 mm.
Installing the unit
• The unit is installed on the ceiling with the built-in brackets,
and threaded rods, with the neck facing the wall.
A) Preparing the hole for the piping
1) Measure carefully the position of the hole in the wall
where the piping is to be connected.
A
Susurro 400 1408 mm
Susurro 700 1648 mm
Susurro 1000 1920 mm
B
Susurro 400 250 mm
Susurro 700 315 mm
Susurro 1000 315 mm
2) Drill the holes
600 mm
Your partner in ventilation...
INSTALLATION AND ASSEMBLY
The unit is designed for installation in the vertical position.
Other installation position is not possible.
Installation of the unit shall allow a sufficient access for
performing maintenance, servicing, and dismounting
operations.
AUFSTELLUNG UND AUFBAU
Das Gerät ist zum Einbau in vertikaler Position bestimmt.
Andere Einbauposition ist nicht möglich.
Das Gerät muss so installiert sein, dass ein ausreichender
Zugang zwecksWartung, Service, oder deren Demontage
garantiert wird.
- The unit is fixed using suspension holders located on both
sidewalls of the unit.
- The unit shall be fixed safely to avoid its dropping.
- No flammable materials are allowed within 100 mm of the
unit housing and within 500 mm of the inlet sleeve of theunit.
- The air duct is connected by slipping it over the circular neck
with a rubber sealing ring
- It is necessary to install a siphon (accessory) to the
condensate exhaust
- The minimal degree of incline of the siphon is calculated
according to the formula (see Calculation of siphon height)
- Das Gerät wird mit Anhängehaltern an beiden Seiten des
Gerätes befestigt
- Das Gerät ist so zu befestigen, dass diese nicht abstürzen
kann
- in der Entfernung 100 mm vom Gehäuse des Gerätes und 500
mm vom Eingangsstutzen des Gerätes dürfen sich keine
brennbaren Stoffe befinden
- Der Anschluss der Luftleitung erfolgt durch Aufschieben auf
die Rundstutzen mit einem Gummidichtungsring.
- Für die Kondensatausscheidung muss ein Siphon (Zubehör)
installiert werden.
- Die minimale Überhöhung des Siphons berechnet sich nach
der unter „Berechnung der Siphonhöhe“ genannten Formel.
Necessary space for service
Notwendiger Servisraum
200 mm 200 mm
200 mm
Produced in EU
HEAT RECOVERY WÄRMERUECKGEWINNUNG
The company reserves the right of change without previous announcement. ©2VV, spol. s r.o.
320
ISIS Recover HR-A
600 mm
Your partner in ventilation...
INSTALLATION AND ASSEMBLY
The unit is designed for installation in the vertical position.
Other installation position is not possible.
Installation of the unit shall allow a sufficient access for
performing maintenance, servicing, and dismounting
operations.
AUFSTELLUNG UND AUFBAU
Das Gerät ist zum Einbau in vertikaler Position bestimmt.
Andere Einbauposition ist nicht möglich.
Das Gerät muss so installiert sein, dass ein ausreichender
Zugang zwecksWartung, Service, oder deren Demontage
garantiert wird.
- The unit is fixed using suspension holders located on both
sidewalls of the unit.
- The unit shall be fixed safely to avoid its dropping.
- No flammable materials are allowed within 100 mm of the
unit housing and within 500 mm of the inlet sleeve of theunit.
- The air duct is connected by slipping it over the circular neck
with a rubber sealing ring
- It is necessary to install a siphon (accessory) to the
condensate exhaust
- The minimal degree of incline of the siphon is calculated
according to the formula (see Calculation of siphon height)
- Das Gerät wird mit Anhängehaltern an beiden Seiten des
Gerätes befestigt
- Das Gerät ist so zu befestigen, dass diese nicht abstürzen
kann
- in der Entfernung 100 mm vom Gehäuse des Gerätes und 500
mm vom Eingangsstutzen des Gerätes dürfen sich keine
brennbaren Stoffe befinden
- Der Anschluss der Luftleitung erfolgt durch Aufschieben auf
die Rundstutzen mit einem Gummidichtungsring.
- Für die Kondensatausscheidung muss ein Siphon (Zubehör)
installiert werden.
- Die minimale Überhöhung des Siphons berechnet sich nach
der unter „Berechnung der Siphonhöhe“ genannten Formel.
Necessary space for service
Notwendiger Servisraum
200 mm 200 mm
200 mm
Produced in EU
HEAT RECOVERY WÄRMERUECKGEWINNUNG
The company reserves the right of change without previous announcement. ©2VV, spol. s r.o.
320
ISIS Recover HR-A
600 mm
Your partner in ventilation...
INSTALLATION AND ASSEMBLY
The unit is designed for installation in the vertical position.
Other installation position is not possible.
Installation of the unit shall allow a sufficient access for
performing maintenance, servicing, and dismounting
operations.
AUFSTELLUNG UND AUFBAU
Das Gerät ist zum Einbau in vertikaler Position bestimmt.
Andere Einbauposition ist nicht möglich.
Das Gerät muss so installiert sein, dass ein ausreichender
Zugang zwecksWartung, Service, oder deren Demontage
garantiert wird.
- The unit is fixed using suspension holders located on both
sidewalls of the unit.
- The unit shall be fixed safely to avoid its dropping.
- No flammable materials are allowed within 100 mm of the
unit housing and within 500 mm of the inlet sleeve of theunit.
- The air duct is connected by slipping it over the circular neck
with a rubber sealing ring
- It is necessary to install a siphon (accessory) to the
condensate exhaust
- The minimal degree of incline of the siphon is calculated
according to the formula (see Calculation of siphon height)
- Das Gerät wird mit Anhängehaltern an beiden Seiten des
Gerätes befestigt
- Das Gerät ist so zu befestigen, dass diese nicht abstürzen
kann
- in der Entfernung 100 mm vom Gehäuse des Gerätes und 500
mm vom Eingangsstutzen des Gerätes dürfen sich keine
brennbaren Stoffe befinden
- Der Anschluss der Luftleitung erfolgt durch Aufschieben auf
die Rundstutzen mit einem Gummidichtungsring.
- Für die Kondensatausscheidung muss ein Siphon (Zubehör)
installiert werden.
- Die minimale Überhöhung des Siphons berechnet sich nach
der unter „Berechnung der Siphonhöhe“ genannten Formel.
Necessary space for service
Notwendiger Servisraum
200 mm 200 mm
200 mm
Produced in EU
HEAT RECOVERY WÄRMERUECKGEWINNUNG
The company reserves the right of change without previous announcement. ©2VV, spol. s r.o.
320
ISIS Recover HR-A
A
BB
min. 0 mm
A
Fan / Ventilator
Heat exchanger / Wärmetauscher
Filter / Filter
Regulation / die Regulation
Condesate exhaust / Kondensatausscheidung
Afterheater / Nachheizeinrichtung / DX / CO
By-pass ap / By-pass Klappe
Preheater / Vorwärmer
Operational diagram
Funktionsschema
Fan / Ventilator
Heat exchanger / Wärmetauscher
Filter / Filter
Regulation / die Regulation
Condesate exhaust / Kondensatausscheidung
Afterheater / Nachheizeinrichtung / DX / CO
By-pass ap / By-pass Klappe
Preheater / Vorwärmer
Operational diagram
Funktionsschema
B
INSTRUCTION MANUAL
Susurr
TM

INSTALLATION
10
B) Preparing the attachment to the ceiling
1) Measure carefully the position of the holes for the threaded rods
(not included)
2) Drill the holes
3) Install threaded rods of the appropriate length
CDE
C
Susurro 400 110 mm
Susurro 700 168 mm
Susurro 1000 150 mm
D
Susurro 400 689 mm
Susurro 700 763 mm
Susurro 1000 962 mm
E
Susurro 400 1835 mm
Susurro 700 2105 mm
Susurro 1000 2435 mm
INSTRUCTION MANUAL
Susurr
TM

INSTALLATION
11
© Airow - All rights reserved
C) Preparing the unit
The design version may require to remove the side covers.
You will need a no. 3 Allen wrench.
Move the cover upwards to remove it. It is secured by auxiliary
brackets (see following picture).
Removed cover with brackets
INSTRUCTION MANUAL
Susurr
TM

INSTALLATION
12
• Hang the unit from the rods and secure the holes in the wall
appropriately.
• Install protection grilles on the outside of the wall to prevent the
ingress of water and bigger objects. (not included)
• Control the xing
INSTRUCTION MANUAL
Susurr
TM

INSTALLATION
13
© Airow - All rights reserved
How to open the lid
Disconnect the unit with the main switch before opening the
lid. Be especially careful when manipulating it.
Access to the electric connection and electronics
This part is located inside the unit, on the left side, below the
intake lter.
To access the electronics, remove the following screws
Electronic parts:
1) Remove 12 screws on the lower side
CAUTION: The door is only held by the hinges. After
removing the
screws keep on holding the door to prevent its opening
1
5
2
3
A
G
4
6
AElectronic board - Module A
GElectronic board - Module G
1Terminals for the power supply (L) and the output of the
auxiliary power supply (12V, 24V)
2Terminals to connect N and PE cables
3Auxiliary power supply (12V, 24V)
4Engine fuse
5Main power switch
6Safety Contactor (units with electric heater)
INSTRUCTION MANUAL
Susurr
TM

INSTALLATION
PLEASE NOTE!
• The sink must be well connected to the unit
and sealed.
• We recommend to submerge the sink in water check its
integrity.
ATTENTION!
If the sink is not well connected, the unit may be
ooded and damaged.
CONNECTING THE CONDENSATE DRAIN
5 °
max 3.5m
22mm
Sink (SK-HL138)
it can be mounted on the wall or embedded.
(non included)
INSTALLATION OF THE RECOMMENDED TYPES:
Sink (SK-AKS3)
(non included)
14
INSTRUCTION MANUAL
Susurr
TM

INSTALLATION
Electric power cable
●
The power cable is not included. It has to be procured before
the installation. Choose the type and thickness of the cable
according to the unit’s maximum consumption and the specic
requirements of the place of installation.
TECHNICAL INFORMATION
●
The electrical parameters can be found on the manufacturer's
labels inside and on the side of the unit (Fig. 1).
ELECTRIC INSTALLATION AND WIRING
CAUTION!
• The main power supply must be turned off before
working on the internal parts of the unit.
• The electrical installation must be done pursuant to
the technical documentation and by a certied electri-
cian. The installation might be done by a professional
with qualications in electricity. The manual must ob-
served, together with the laws and regulations appli-
cable in the country.
• The wiring diagrams in the product have a higher
priority than those in manual. Before the installa-
tion, check that the indication of the terminals corre-
sponds to the wiring connection diagram. In case of
doubt, contact the supplier and do not connect the
unit under any circumstances.
• The unit must be connected to the main power source
with an isolated cable with a heat resistance in com-
pliance with the diameter and the applicable laws and
regulations of the country.
• Any altering or changes to the internal connections
of the unit are forbidden and may result in the loss of
warranty.
• Only the use of original accessories guarantees the
correct function of the unit.
All the unit's electrical circuits must be connected through an
earth leakage breaker according to the current model.
The unit must be connected in a way that it can be disconnected
from the power supply with one piece.
Table of minimum sizes of breakers according to the model of
heat recovery unit.
Recommended minimum values of the circuit breakers:
Circuit breakers
Susurro 700 13A (1F)
Susurro 700 10A (3F)
Susurro 700 13A (1F)
Accessories
Connect the electric accessories of the unit to the connecting
terminal, as shown in the diagram and the indications of the
terminals.
Product designation
Serial number
• U = Voltage
• f = Frequency
• n = Speed
• ph = Phase
• av = Air output
• I = Total current
• P = Output
• m = weight
• IP = IP cover
• ver = designation for producer
(Fig. 1) Location of the label and explanation of each part.
Airow Developments Limited
Aidelle House, Lancaster Road,
Cressex Business Park,
High Wycombe, Buckinghamshire,
United Kingdom, HP12 3QP
airow.com
15
© Airow - All rights reserved
INSTRUCTION MANUAL
Susurr
TM

INSTALLATION
UNIT WITH COMFORT REGULATION:
The control is located inside the unit.
ELECTRIC POWER DIAGRAM AND CONNECTION OF ACCESSORIES:
CT-ROOM
EN RU PL IT CS
1SMU - power supply Смесительный узел – источник питания Układ mieszający zasilanie Punto di miscelazione - alimentazione SMU - napájení
2Control signal (adjustable: SMU, heater/
cooler)
Управляющий сигнал (регулируемый: SMU,
обогреватель/кулер)
Sygnał sterujący ( do nastawienia : SMU,heater/
cooler)
Segnale di controllo (impostabile: SMU, heater/
cooler)
Řídící signál (nastavitelné: SMU, heater/
cooler)
3Spatial sensor Внутренний датчик Czujnik przestrzenny Sensore ambientale Prostorové čidlo teploty
4Flap - inlet (fresh air) Клапан свежего воздуха Klapa świeżego powietrza Aletta – Aria fresca Klapka pro čerstvý vzduch
5Flap - outlet Клапан отработанного воздуха Klapa wydechu Aletta - Scarico Klapka pro odvodní vzduch
6Water pump Водяной насос (конденсат) Pompa wodna Pompa dell‘acqua Vodní čerpadlo
7RUN function (adjustable in units with direct
evaporator: 0-10V/ON-OFF)
Функция RUN (у модулей с прямым
выпаривателем можно настроить: 0-10V/ON-OFF)
Funkcja RUN (u jednostek z parownikiem bez-
pośrednim do nastawienia : 0-10V/ON-OFF)
Funzione RUN (impostabile per le unità dotate
dell’evaporatore diretto: 0-10V/ON-OFF)
Funkce RUN (nastavitelné s jednotkou s
přímím výparníkem 0-10V / ON/OFF)
8C/O - cooling/heating C/O - охлаждение/ обогрев C/O - chłodzenie / ogrzewanie C/O – raffreddamento/riscaldamento C/O - chlazení/topení
9Direct evaporator - ERROR Прямой выпариватель - ERROR Prosty parownik – ERROR (błąd) Evaporatore diretto – ERROR Přímý výparník - ERROR
10 Direct evaporator - defrost Прямой выпариватель - РАЗМОРОЗКА Prosty parownik - odmrażanie Evaporatore diretto - SCONGELAMENTO Přímý výparník - ODMRAŽOVÁNÍ
11 External control -ON/OFF Внешнее управление Sterowanie zewnętrzne Wł./Wył. Accensione/spegnimento esterno Externí ovládání ON/OFF
12 Alarm - FIRE Пожарный извещатель Wejście stycznika pożarowego Fiamma Poplach - FIRE
13 BOOST regime Функция Boost Funkcja BOOST Boost Režim BOOST
14 Recuperator - ERROR Ошибка рекуператора Usterka rekuperatora Errore – recuperatore Chyba rekuperátoru
15 The air quality sensor - power supply CO2/RH/VOC - источник питания CO2/RH/VOC - zasilanie CO2/RH/VOC - alimentazione Čidlo kvality vzduchu - napájení
16 The air quality sensor - control signal CO2/RH/VOC - данные CO2/RH/VOC - data CO2/RH/VOC - dati Čidlo kvality vzduchu - ovládání
17 Presence sensor Датчик движения Czujnik ruchu Sensore di presenza Čidlo přítomnosti
N - Neutral
Entrée
24VAC
24V GND
GND
GND
CAPTEUR
PRÉSENCE
DX GENERAL ERROR
(settable)
DX DEFROST
(settable)
230VAC
GND
21
V+ 0-10 VDC
CO2/RH/VOC/EXT
CO2/ RH/VOC
EXTERNAL
CAPTEUR 0-10V
15VAC
Capteur CO /HR
VDC
0-10
24VAC
Alimentation
vanne
0-10V
Vanne/ Groupe Exterieur DX
Capteur Externe.
Câble deux fils blindé
alimentation générale
Registre
max.1A
max. 50 m
Air Neuf
79 80
70 69 68 67 66 65
81 82 55 56
Registre
Air Rejeté
77 78
23 24
230VAC
POMPE
DE CIRCULATION
76 75
25 26 49 50
59 60
OUTPUT
DX = ON/OFF
(Sortie pour unité
exterieure)
72 71
CONTACT
ERREUR
Commande
á distance
63 64
CONTACT
EXTERNE
ON/OFF
53 54 51 52
CONTACT
INCENDIE
CMSI
62 61
BOOST
BOOST
57 58
boitier de commande
J1/J2
GND GND
1513 14
9
8
7
10
5
4
3
2
1
6
12
11
16 17 18 19 20 21 22 23 24
8283 81 80 79 78 77 76 75 74 73
25 26 27 28 29
68 67 66 65 64 63 62 61 60 59 58 57 56 55 54 53 52 51
31 33 35 36 37 38 39 40 41 42 43
9
44 45 46 47 48 49 5030 32 34
72 71 70 69
GND
N L LO L LO L LO N
GND
GND
0-10V
+SSR -SSR
GND
0-10V
VENT-INT
230VAC
PIR
230VAC
FLAP-INT
230VAC
FLAP-EXT
230VAC
W. PUMP
ALARM
HEATER
RUN
OUTPUT
COOL/HEAT
HEAT PUMP HEAT PUMP
ERROR DEFROST
EXTERNAL
ON/OFF
FIRE BOOST
PRESENCE
SENSOR
PIR
REC ERR
TRANSF-
24VAC
TRANSF-
15VAC
TRANSF-
12VAC
L-VENT
INT-EXT
LN
N
L-TR
N-TR
~
VENT-EXT
HEATER/
COOL/PUMP
PREHEATER
0-10V GND
POSTHEATER
REC/BYP
GNDPWM GNDPWM
RPM
(TC)
RPM 24VAC 24VAC
T-EXT-1 T-EXT-2 T-EXT-3 T-INT-1 T-INT-2
FILTER
INT
T-WATER T-WATER T-ROOM
JP1
LED1
DATA
SWO
TX
RX
-OUT -IN
(TC)
1
~
2
~
1
~
2
15VAC IN GND
CO2/RH/EXT
2
1
12
10
ModBUS RTU via
Rs485
GTC
ou
FUSE
(VENT-EXT)
FUSE
(VENT-INT)
FUSE
(PCB)
FUSE
(PERIPHERY)
!
!
defrost
24VAC
POWER SUPPLY
MIX POINT
MIX. POINT / OUTDOOR
UNIT DX
INPUT
MAIN ELECTRIC SUPPLY
EXT. SENSOR
(two-wire shielded cable)
or
INLET -Fresh air OUTLET DX = ON/OFF
(Output for outdoor unit)
Control panel
EXTERNAL
CONTROL FIRE
WATER
PUMP CONTROL ERROR
CONTACT
PRESENCE
SENSOR
SENSOR
SENSOR
1
5
6
11
17
15 16
23
4712 13 14
8910
E-SCH-RGJ-HR85
3-050-D06378
EN RU PL IT CS
1SMU - power supply Смесительный узел – источник питания Układ mieszający zasilanie Punto di miscelazione - alimentazione SMU - napájení
2Control signal (adjustable: SMU, heater/
cooler)
Управляющий сигнал (регулируемый: SMU,
обогреватель/кулер)
Sygnał sterujący ( do nastawienia : SMU,heater/
cooler)
Segnale di controllo (impostabile: SMU, heater/
cooler)
Řídící signál (nastavitelné: SMU, heater/
cooler)
3Spatial sensor Внутренний датчик Czujnik przestrzenny Sensore ambientale Prostorové čidlo teploty
4Flap - inlet (fresh air) Клапан свежего воздуха Klapa świeżego powietrza Aletta – Aria fresca Klapka pro čerstvý vzduch
5Flap - outlet Клапан отработанного воздуха Klapa wydechu Aletta - Scarico Klapka pro odvodní vzduch
6Water pump Водяной насос (конденсат) Pompa wodna Pompa dell‘acqua Vodní čerpadlo
7RUN function (adjustable in units with direct
evaporator: 0-10V/ON-OFF)
Функция RUN (у модулей с прямым
выпаривателем можно настроить: 0-10V/ON-OFF)
Funkcja RUN (u jednostek z parownikiem bez-
pośrednim do nastawienia : 0-10V/ON-OFF)
Funzione RUN (impostabile per le unità dotate
dell’evaporatore diretto: 0-10V/ON-OFF)
Funkce RUN (nastavitelné s jednotkou s
přímím výparníkem 0-10V / ON/OFF)
8C/O - cooling/heating C/O - охлаждение/ обогрев C/O - chłodzenie / ogrzewanie C/O – raffreddamento/riscaldamento C/O - chlazení/topení
9Direct evaporator - ERROR Прямой выпариватель - ERROR Prosty parownik – ERROR (błąd) Evaporatore diretto – ERROR Přímý výparník - ERROR
10 Direct evaporator - defrost Прямой выпариватель - РАЗМОРОЗКА Prosty parownik - odmrażanie Evaporatore diretto - SCONGELAMENTO Přímý výparník - ODMRAŽOVÁNÍ
11 External control -ON/OFF Внешнее управление Sterowanie zewnętrzne Wł./Wył. Accensione/spegnimento esterno Externí ovládání ON/OFF
12 Alarm - FIRE Пожарный извещатель Wejście stycznika pożarowego Fiamma Poplach - FIRE
13 BOOST regime Функция Boost Funkcja BOOST Boost Režim BOOST
14 Recuperator - ERROR Ошибка рекуператора Usterka rekuperatora Errore – recuperatore Chyba rekuperátoru
15 The air quality sensor - power supply CO2/RH/VOC - источник питания CO2/RH/VOC - zasilanie CO2/RH/VOC - alimentazione Čidlo kvality vzduchu - napájení
16 The air quality sensor - control signal CO2/RH/VOC - данные CO2/RH/VOC - data CO2/RH/VOC - dati Čidlo kvality vzduchu - ovládání
17 Presence sensor Датчик движения Czujnik ruchu Sensore di presenza Čidlo přítomnosti
N - Neutral
Entrée
24VAC
24V GND
GND
GND
CAPTEUR
PRÉSENCE
DX GENERAL ERROR
(settable)
DX DEFROST
(settable)
230VAC
GND
21
V+ 0-10 VDC
CO2/RH/VOC/EXT
CO2/ RH/VOC
EXTERNAL
CAPTEUR 0-10V
15VAC
Capteur CO /HR
VDC
0-10
24VAC
Alimentation
vanne
0-10V
Vanne/ Groupe Exterieur DX
Capteur Externe.
Câble deux fils blindé
alimentation générale
Registre
max.1A
max. 50 m
Air Neuf
79 80
70 69 68 67 66 65
81 82 55 56
Registre
Air Rejeté
77 78
23 24
230VAC
POMPE
DE CIRCULATION
76 75
25 26 49 50
59 60
OUTPUT
DX = ON/OFF
(Sortie pour unité
exterieure)
72 71
CONTACT
ERREUR
Commande
á distance
63 64
CONTACT
EXTERNE
ON/OFF
53 54 51 52
CONTACT
INCENDIE
CMSI
62 61
BOOST
BOOST
57 58
boitier de commande
J1/J2
GND GND
1513 14
9
8
7
10
5
4
3
2
1
6
12
11
16 17 18 19 20 21 22 23 24
8283 81 80 79 78 77 76 75 74 73
25 26 27 28 29
68 67 66 65 64 63 62 61 60 59 58 57 56 55 54 53 52 51
31 33 35 36 37 38 39 40 41 42 43
9
44 45 46 47 48 49 5030 32 34
72 71 70 69
GND
N L LO L LO L LO N
GND
GND
0-10V
+SSR -SSR
GND
0-10V
VENT-INT
230VAC
PIR
230VAC
FLAP-INT
230VAC
FLAP-EXT
230VAC
W. PUMP
ALARM
HEATER
RUN
OUTPUT
COOL/HEAT
HEAT PUMP HEAT PUMP
ERROR DEFROST
EXTERNAL
ON/OFF
FIRE BOOST
PRESENCE
SENSOR
PIR
REC ERR
TRANSF-
24VAC
TRANSF-
15VAC
TRANSF-
12VAC
L-VENT
INT-EXT
LN
N
L-TR
N-TR
~
VENT-EXT
HEATER/
COOL/PUMP
PREHEATER
0-10V GND
POSTHEATER
REC/BYP
GNDPWM GNDPWM
RPM
(TC)
RPM 24VAC 24VAC
T-EXT-1 T-EXT-2 T-EXT-3 T-INT-1 T-INT-2
FILTER
INT
T-WATER T-WATER T-ROOM
JP1
LED1
DATA
SWO
TX
RX
-OUT -IN
(TC)
1
~
2
~
1
~
2
15VAC IN GND
CO2/RH/EXT
2
1
12
10
ModBUS RTU via
Rs485
GTC
ou
FUSE
(VENT-EXT)
FUSE
(VENT-INT)
FUSE
(PCB)
FUSE
(PERIPHERY)
!
!
defrost
24VAC
POWER SUPPLY
MIX POINT
MIX. POINT / OUTDOOR
UNIT DX
INPUT
MAIN ELECTRIC SUPPLY
EXT. SENSOR
(two-wire shielded cable)
or
INLET -Fresh air OUTLET DX = ON/OFF
(Output for outdoor unit)
Control panel
EXTERNAL
CONTROL FIRE
WATER
PUMP CONTROL ERROR
CONTACT
PRESENCE
SENSOR
SENSOR
SENSOR
1
5
6
11
17
15 16
23
4712 13 14
8910
E-SCH-RGJ-HR85
3-050-D06378
79
8
PREHEAT
W. PUMP
BOOST EXT
EN RU PL IT CS
1SMU - power supply Смесительный узел – источник питания Układ mieszający zasilanie Punto di miscelazione - alimentazione SMU - napájení
2Control signal (adjustable: SMU, heater/
cooler)
Управляющий сигнал (регулируемый: SMU,
обогреватель/кулер)
Sygnał sterujący ( do nastawienia : SMU,heater/
cooler)
Segnale di controllo (impostabile: SMU, heater/
cooler)
Řídící signál (nastavitelné: SMU, heater/
cooler)
3Spatial sensor Внутренний датчик Czujnik przestrzenny Sensore ambientale Prostorové čidlo teploty
4Flap - inlet (fresh air) Клапан свежего воздуха Klapa świeżego powietrza Aletta – Aria fresca Klapka pro čerstvý vzduch
5Flap - outlet Клапан отработанного воздуха Klapa wydechu Aletta - Scarico Klapka pro odvodní vzduch
6Water pump Водяной насос (конденсат) Pompa wodna Pompa dell‘acqua Vodní čerpadlo
7RUN function (adjustable in units with direct
evaporator: 0-10V/ON-OFF)
Функция RUN (у модулей с прямым
выпаривателем можно настроить: 0-10V/ON-OFF)
Funkcja RUN (u jednostek z parownikiem bez-
pośrednim do nastawienia : 0-10V/ON-OFF)
Funzione RUN (impostabile per le unità dotate
dell’evaporatore diretto: 0-10V/ON-OFF)
Funkce RUN (nastavitelné s jednotkou s
přímím výparníkem 0-10V / ON/OFF)
8C/O - cooling/heating C/O - охлаждение/ обогрев C/O - chłodzenie / ogrzewanie C/O – raffreddamento/riscaldamento C/O - chlazení/topení
9Direct evaporator - ERROR Прямой выпариватель - ERROR Prosty parownik – ERROR (błąd) Evaporatore diretto – ERROR Přímý výparník - ERROR
10 Direct evaporator - defrost Прямой выпариватель - РАЗМОРОЗКА Prosty parownik - odmrażanie Evaporatore diretto - SCONGELAMENTO Přímý výparník - ODMRAŽOVÁNÍ
11 External control -ON/OFF Внешнее управление Sterowanie zewnętrzne Wł./Wył. Accensione/spegnimento esterno Externí ovládání ON/OFF
12 Alarm - FIRE Пожарный извещатель Wejście stycznika pożarowego Fiamma Poplach - FIRE
13 BOOST regime Функция Boost Funkcja BOOST Boost Režim BOOST
14 Recuperator - ERROR Ошибка рекуператора Usterka rekuperatora Errore – recuperatore Chyba rekuperátoru
15 The air quality sensor - power supply CO2/RH/VOC - источник питания CO2/RH/VOC - zasilanie CO2/RH/VOC - alimentazione Čidlo kvality vzduchu - napájení
16 The air quality sensor - control signal CO2/RH/VOC - данные CO2/RH/VOC - data CO2/RH/VOC - dati Čidlo kvality vzduchu - ovládání
17 Presence sensor Датчик движения Czujnik ruchu Sensore di presenza Čidlo přítomnosti
N - Neutral
Entrée
24VAC
24V GND
GND
GND
CAPTEUR
PRÉSENCE
DX GENERAL ERROR
(settable)
DX DEFROST
(settable)
230VAC
GND
21
V+ 0-10 VDC
CO2/RH/VOC/EXT
CO2/ RH/VOC
EXTERNAL
CAPTEUR 0-10V
15VAC
Capteur CO /HR
VDC
0-10
24VAC
Alimentation
vanne
0-10V
Vanne/ Groupe Exterieur DX
Capteur Externe.
Câble deux fils blindé
alimentation générale
Registre
max.1A
max. 50 m
Air Neuf
79 80
70 69 68 67 66 65
81 82 55 56
Registre
Air Rejeté
77 78
23 24
230VAC
POMPE
DE CIRCULATION
76 75
25 26 49 50
59 60
OUTPUT
DX = ON/OFF
(Sortie pour unité
exterieure)
72 71
CONTACT
ERREUR
Commande
á distance
63 64
CONTACT
EXTERNE
ON/OFF
53 54 51 52
CONTACT
INCENDIE
CMSI
62 61
BOOST
BOOST
57 58
boitier de commande
J1/J2
GND GND
1513 14
9
8
7
10
5
4
3
2
1
6
12
11
16 17 18 19 20 21 22 23 24
8283 81 80 79 78 77 76 75 74 73
25 26 27 28 29
68 67 66 65 64 63 62 61 60 59 58 57 56 55 54 53 52 51
31 33 35 36 37 38 39 40 41 42 43
9
44 45 46 47 48 49 5030 32 34
72 71 70 69
GND
N L LO L LO L LO N
GND
GND
0-10V
+SSR -SSR
GND
0-10V
VENT-INT
230VAC
PIR
230VAC
FLAP-INT
230VAC
FLAP-EXT
230VAC
W. PUMP
ALARM
HEATER
RUN
OUTPUT
COOL/HEAT
HEAT PUMP HEAT PUMP
ERROR DEFROST
EXTERNAL
ON/OFF
FIRE BOOST
PRESENCE
SENSOR
PIR
REC ERR
TRANSF-
24VAC
TRANSF-
15VAC
TRANSF-
12VAC
L-VENT
INT-EXT
LN
N
L-TR
N-TR
~
VENT-EXT
HEATER/
COOL/PUMP
PREHEATER
0-10V GND
POSTHEATER
REC/BYP
GNDPWM GNDPWM
RPM
(TC)
RPM 24VAC 24VAC
T-EXT-1 T-EXT-2 T-EXT-3 T-INT-1 T-INT-2
FILTER
INT
T-WATER T-WATER T-ROOM
JP1
LED1
DATA
SWO
TX
RX
-OUT -IN
(TC)
1
~
2
~
1
~
2
15VAC IN GND
CO2/RH/EXT
2
1
12
10
ModBUS RTU via
Rs485
GTC
ou
FUSE
(VENT-EXT)
FUSE
(VENT-INT)
FUSE
(PCB)
FUSE
(PERIPHERY)
!
!
defrost
24VAC
POWER SUPPLY
MIX POINT
MIX. POINT / OUTDOOR
UNIT DX
INPUT
MAIN ELECTRIC SUPPLY
EXT. SENSOR
(two-wire shielded cable)
or
INLET -Fresh air OUTLET DX = ON/OFF
(Output for outdoor unit)
Control panel
EXTERNAL
CONTROL FIRE
WATER
PUMP CONTROL ERROR
CONTACT
PRESENCE
SENSOR
SENSOR
SENSOR
1
5
6
11
17
15 16
23
4712 13 14
8910
E-SCH-RGJ-HR85
3-050-D06378
1310 14
EN RU PL IT CS
1SMU - power supply Смесительный узел – источник питания Układ mieszający zasilanie Punto di miscelazione - alimentazione SMU - napájení
2Control signal (adjustable: SMU, heater/
cooler)
Управляющий сигнал (регулируемый: SMU,
обогреватель/кулер)
Sygnał sterujący ( do nastawienia : SMU,heater/
cooler)
Segnale di controllo (impostabile: SMU, heater/
cooler)
Řídící signál (nastavitelné: SMU, heater/
cooler)
3Spatial sensor Внутренний датчик Czujnik przestrzenny Sensore ambientale Prostorové čidlo teploty
4Flap - inlet (fresh air) Клапан свежего воздуха Klapa świeżego powietrza Aletta – Aria fresca Klapka pro čerstvý vzduch
5Flap - outlet Клапан отработанного воздуха Klapa wydechu Aletta - Scarico Klapka pro odvodní vzduch
6Water pump Водяной насос (конденсат) Pompa wodna Pompa dell‘acqua Vodní čerpadlo
7RUN function (adjustable in units with direct
evaporator: 0-10V/ON-OFF)
Функция RUN (у модулей с прямым
выпаривателем можно настроить: 0-10V/ON-OFF)
Funkcja RUN (u jednostek z parownikiem bez-
pośrednim do nastawienia : 0-10V/ON-OFF)
Funzione RUN (impostabile per le unità dotate
dell’evaporatore diretto: 0-10V/ON-OFF)
Funkce RUN (nastavitelné s jednotkou s
přímím výparníkem 0-10V / ON/OFF)
8C/O - cooling/heating C/O - охлаждение/ обогрев C/O - chłodzenie / ogrzewanie C/O – raffreddamento/riscaldamento C/O - chlazení/topení
9Direct evaporator - ERROR Прямой выпариватель - ERROR Prosty parownik – ERROR (błąd) Evaporatore diretto – ERROR Přímý výparník - ERROR
10 Direct evaporator - defrost Прямой выпариватель - РАЗМОРОЗКА Prosty parownik - odmrażanie Evaporatore diretto - SCONGELAMENTO Přímý výparník - ODMRAŽOVÁNÍ
11 External control -ON/OFF Внешнее управление Sterowanie zewnętrzne Wł./Wył. Accensione/spegnimento esterno Externí ovládání ON/OFF
12 Alarm - FIRE Пожарный извещатель Wejście stycznika pożarowego Fiamma Poplach - FIRE
13 BOOST regime Функция Boost Funkcja BOOST Boost Režim BOOST
14 Recuperator - ERROR Ошибка рекуператора Usterka rekuperatora Errore – recuperatore Chyba rekuperátoru
15 The air quality sensor - power supply CO2/RH/VOC - источник питания CO2/RH/VOC - zasilanie CO2/RH/VOC - alimentazione Čidlo kvality vzduchu - napájení
16 The air quality sensor - control signal CO2/RH/VOC - данные CO2/RH/VOC - data CO2/RH/VOC - dati Čidlo kvality vzduchu - ovládání
17 Presence sensor Датчик движения Czujnik ruchu Sensore di presenza Čidlo přítomnosti
N - Neutral
Entrée
24VAC
24V GND
GND
GND
CAPTEUR
PRÉSENCE
DX GENERAL ERROR
(settable)
DX DEFROST
(settable)
230VAC
GND
21
V+ 0-10 VDC
CO2/RH/VOC/EXT
CO2/ RH/VOC
EXTERNAL
CAPTEUR 0-10V
15VAC
Capteur CO /HR
VDC
0-10
24VAC
Alimentation
vanne
0-10V
Vanne/ Groupe Exterieur DX
Capteur Externe.
Câble deux fils blindé
alimentation générale
Registre
max.1A
max. 50 m
Air Neuf
79 80
70 69 68 67 66 65
81 82 55 56
Registre
Air Rejeté
77 78
23 24
230VAC
POMPE
DE CIRCULATION
76 75
25 26 49 50
59 60
OUTPUT
DX = ON/OFF
(Sortie pour unité
exterieure)
72 71
CONTACT
ERREUR
Commande
á distance
63 64
CONTACT
EXTERNE
ON/OFF
53 54 51 52
CONTACT
INCENDIE
CMSI
62 61
BOOST
BOOST
57 58
boitier de commande
J1/J2
GND GND
1513 14
9
8
7
10
5
4
3
2
1
6
12
11
16 17 18 19 20 21 22 23 24
8283 81 80 79 78 77 76 75 74 73
25 26 27 28 29
68 67 66 65 64 63 62 61 60 59 58 57 56 55 54 53 52 51
31 33 35 36 37 38 39 40 41 42 43
9
44 45 46 47 48 49 5030 32 34
72 71 70 69
GND
N L LO L LO L LO N
GND
GND
0-10V
+SSR -SSR
GND
0-10V
VENT-INT
230VAC
PIR
230VAC
FLAP-INT
230VAC
FLAP-EXT
230VAC
W. PUMP
ALARM
HEATER
RUN
OUTPUT
COOL/HEAT
HEAT PUMP HEAT PUMP
ERROR DEFROST
EXTERNAL
ON/OFF
FIRE BOOST
PRESENCE
SENSOR
PIR
REC ERR
TRANSF-
24VAC
TRANSF-
15VAC
TRANSF-
12VAC
L-VENT
INT-EXT
LN
N
L-TR
N-TR
~
VENT-EXT
HEATER/
COOL/PUMP
PREHEATER
0-10V GND
POSTHEATER
REC/BYP
GNDPWM GNDPWM
RPM
(TC)
RPM 24VAC 24VAC
T-EXT-1 T-EXT-2 T-EXT-3 T-INT-1 T-INT-2
FILTER
INT
T-WATER T-WATER T-ROOM
JP1
LED1
DATA
SWO
TX
RX
-OUT -IN
(TC)
1
~
2
~
1
~
2
15VAC IN GND
CO2/RH/EXT
2
1
12
10
ModBUS RTU via
Rs485
GTC
ou
FUSE
(VENT-EXT)
FUSE
(VENT-INT)
FUSE
(PCB)
FUSE
(PERIPHERY)
!
!
defrost
24VAC
POWER SUPPLY
MIX POINT
MIX. POINT / OUTDOOR
UNIT DX
INPUT
MAIN ELECTRIC SUPPLY
EXT. SENSOR
(two-wire shielded cable)
or
INLET -Fresh air OUTLET DX = ON/OFF
(Output for outdoor unit)
Control panel
EXTERNAL
CONTROL FIRE
WATER
PUMP CONTROL ERROR
CONTACT
PRESENCE
SENSOR
SENSOR
SENSOR
1
5
6
11
17
15 16
23
4712 13 14
8910
E-SCH-RGJ-HR85
3-050-D06378
15 16
EN RU PL IT CS
1SMU - power supply Смесительный узел – источник питания Układ mieszający zasilanie Punto di miscelazione - alimentazione SMU - napájení
2Control signal (adjustable: SMU, heater/
cooler)
Управляющий сигнал (регулируемый: SMU,
обогреватель/кулер)
Sygnał sterujący ( do nastawienia : SMU,heater/
cooler)
Segnale di controllo (impostabile: SMU, heater/
cooler)
Řídící signál (nastavitelné: SMU, heater/
cooler)
3Spatial sensor Внутренний датчик Czujnik przestrzenny Sensore ambientale Prostorové čidlo teploty
4Flap - inlet (fresh air) Клапан свежего воздуха Klapa świeżego powietrza Aletta – Aria fresca Klapka pro čerstvý vzduch
5Flap - outlet Клапан отработанного воздуха Klapa wydechu Aletta - Scarico Klapka pro odvodní vzduch
6Water pump Водяной насос (конденсат) Pompa wodna Pompa dell‘acqua Vodní čerpadlo
7RUN function (adjustable in units with direct
evaporator: 0-10V/ON-OFF)
Функция RUN (у модулей с прямым
выпаривателем можно настроить: 0-10V/ON-OFF)
Funkcja RUN (u jednostek z parownikiem bez-
pośrednim do nastawienia : 0-10V/ON-OFF)
Funzione RUN (impostabile per le unità dotate
dell’evaporatore diretto: 0-10V/ON-OFF)
Funkce RUN (nastavitelné s jednotkou s
přímím výparníkem 0-10V / ON/OFF)
8C/O - cooling/heating C/O - охлаждение/ обогрев C/O - chłodzenie / ogrzewanie C/O – raffreddamento/riscaldamento C/O - chlazení/topení
9Direct evaporator - ERROR Прямой выпариватель - ERROR Prosty parownik – ERROR (błąd) Evaporatore diretto – ERROR Přímý výparník - ERROR
10 Direct evaporator - defrost Прямой выпариватель - РАЗМОРОЗКА Prosty parownik - odmrażanie Evaporatore diretto - SCONGELAMENTO Přímý výparník - ODMRAŽOVÁNÍ
11 External control -ON/OFF Внешнее управление Sterowanie zewnętrzne Wł./Wył. Accensione/spegnimento esterno Externí ovládání ON/OFF
12 Alarm - FIRE Пожарный извещатель Wejście stycznika pożarowego Fiamma Poplach - FIRE
13 BOOST regime Функция Boost Funkcja BOOST Boost Režim BOOST
14 Recuperator - ERROR Ошибка рекуператора Usterka rekuperatora Errore – recuperatore Chyba rekuperátoru
15 The air quality sensor - power supply CO2/RH/VOC - источник питания CO2/RH/VOC - zasilanie CO2/RH/VOC - alimentazione Čidlo kvality vzduchu - napájení
16 The air quality sensor - control signal CO2/RH/VOC - данные CO2/RH/VOC - data CO2/RH/VOC - dati Čidlo kvality vzduchu - ovládání
17 Presence sensor Датчик движения Czujnik ruchu Sensore di presenza Čidlo přítomnosti
N - Neutral
Entrée
24VAC
24V GND
GND
GND
CAPTEUR
PRÉSENCE
DX GENERAL ERROR
(settable)
DX DEFROST
(settable)
230VAC
GND
21
V+ 0-10 VDC
CO2/RH/VOC/EXT
CO2/ RH/VOC
EXTERNAL
CAPTEUR 0-10V
15VAC
Capteur CO /HR
VDC
0-10
24VAC
Alimentation
vanne
0-10V
Vanne/ Groupe Exterieur DX
Capteur Externe.
Câble deux fils blindé
alimentation générale
Registre
max.1A
max. 50 m
Air Neuf
79 80
70 69 68 67 66 65
81 82 55 56
Registre
Air Rejeté
77 78
23 24
230VAC
POMPE
DE CIRCULATION
76 75
25 26 49 50
59 60
OUTPUT
DX = ON/OFF
(Sortie pour unité
exterieure)
72 71
CONTACT
ERREUR
Commande
á distance
63 64
CONTACT
EXTERNE
ON/OFF
53 54 51 52
CONTACT
INCENDIE
CMSI
62 61
BOOST
BOOST
57 58
boitier de commande
J1/J2
GND GND
1513 14
9
8
7
10
5
4
3
2
1
6
12
11
16 17 18 19 20 21 22 23 24
8283 81 80 79 78 77 76 75 74 73
25 26 27 28 29
68 67 66 65 64 63 62 61 60 59 58 57 56 55 54 53 52 51
31 33 35 36 37 38 39 40 41 42 43
9
44 45 46 47 48 49 5030 32 34
72 71 70 69
GND
N L LO L LO L LO N
GND
GND
0-10V
+SSR -SSR
GND
0-10V
VENT-INT
230VAC
PIR
230VAC
FLAP-INT
230VAC
FLAP-EXT
230VAC
W. PUMP
ALARM
HEATER
RUN
OUTPUT
COOL/HEAT
HEAT PUMP HEAT PUMP
ERROR DEFROST
EXTERNAL
ON/OFF
FIRE BOOST
PRESENCE
SENSOR
PIR
REC ERR
TRANSF-
24VAC
TRANSF-
15VAC
TRANSF-
12VAC
L-VENT
INT-EXT
LN
N
L-TR
N-TR
~
VENT-EXT
HEATER/
COOL/PUMP
PREHEATER
0-10V GND
POSTHEATER
REC/BYP
GNDPWM GNDPWM
RPM
(TC)
RPM 24VAC 24VAC
T-EXT-1 T-EXT-2 T-EXT-3 T-INT-1 T-INT-2
FILTER
INT
T-WATER T-WATER T-ROOM
JP1
LED1
DATA
SWO
TX
RX
-OUT -IN
(TC)
1
~
2
~
1
~
2
15VAC IN GND
CO2/RH/EXT
2
1
12
10
ModBUS RTU via
Rs485
GTC
ou
FUSE
(VENT-EXT)
FUSE
(VENT-INT)
FUSE
(PCB)
FUSE
(PERIPHERY)
!
!
defrost
24VAC
POWER SUPPLY
MIX POINT
MIX. POINT / OUTDOOR
UNIT DX
INPUT
MAIN ELECTRIC SUPPLY
EXT. SENSOR
(two-wire shielded cable)
or
INLET -Fresh air OUTLET DX = ON/OFF
(Output for outdoor unit)
Control panel
EXTERNAL
CONTROL FIRE
WATER
PUMP CONTROL ERROR
CONTACT
PRESENCE
SENSOR
SENSOR
SENSOR
1
5
6
11
17
15 16
23
4712 13 14
8910
E-SCH-RGJ-HR85
3-050-D06378
EN RU PL IT CS
1SMU - power supply Смесительный узел – источник питания Układ mieszający zasilanie Punto di miscelazione - alimentazione SMU - napájení
2Control signal (adjustable: SMU, heater/
cooler)
Управляющий сигнал (регулируемый: SMU,
обогреватель/кулер)
Sygnał sterujący ( do nastawienia : SMU,heater/
cooler)
Segnale di controllo (impostabile: SMU, heater/
cooler)
Řídící signál (nastavitelné: SMU, heater/
cooler)
3Spatial sensor Внутренний датчик Czujnik przestrzenny Sensore ambientale Prostorové čidlo teploty
4Flap - inlet (fresh air) Клапан свежего воздуха Klapa świeżego powietrza Aletta – Aria fresca Klapka pro čerstvý vzduch
5Flap - outlet Клапан отработанного воздуха Klapa wydechu Aletta - Scarico Klapka pro odvodní vzduch
6Water pump Водяной насос (конденсат) Pompa wodna Pompa dell‘acqua Vodní čerpadlo
7RUN function (adjustable in units with direct
evaporator: 0-10V/ON-OFF)
Функция RUN (у модулей с прямым
выпаривателем можно настроить: 0-10V/ON-OFF)
Funkcja RUN (u jednostek z parownikiem bez-
pośrednim do nastawienia : 0-10V/ON-OFF)
Funzione RUN (impostabile per le unità dotate
dell’evaporatore diretto: 0-10V/ON-OFF)
Funkce RUN (nastavitelné s jednotkou s
přímím výparníkem 0-10V / ON/OFF)
8C/O - cooling/heating C/O - охлаждение/ обогрев C/O - chłodzenie / ogrzewanie C/O – raffreddamento/riscaldamento C/O - chlazení/topení
9Direct evaporator - ERROR Прямой выпариватель - ERROR Prosty parownik – ERROR (błąd) Evaporatore diretto – ERROR Přímý výparník - ERROR
10 Direct evaporator - defrost Прямой выпариватель - РАЗМОРОЗКА Prosty parownik - odmrażanie Evaporatore diretto - SCONGELAMENTO Přímý výparník - ODMRAŽOVÁNÍ
11 External control -ON/OFF Внешнее управление Sterowanie zewnętrzne Wł./Wył. Accensione/spegnimento esterno Externí ovládání ON/OFF
12 Alarm - FIRE Пожарный извещатель Wejście stycznika pożarowego Fiamma Poplach - FIRE
13 BOOST regime Функция Boost Funkcja BOOST Boost Režim BOOST
14 Recuperator - ERROR Ошибка рекуператора Usterka rekuperatora Errore – recuperatore Chyba rekuperátoru
15 The air quality sensor - power supply CO2/RH/VOC - источник питания CO2/RH/VOC - zasilanie CO2/RH/VOC - alimentazione Čidlo kvality vzduchu - napájení
16 The air quality sensor - control signal CO2/RH/VOC - данные CO2/RH/VOC - data CO2/RH/VOC - dati Čidlo kvality vzduchu - ovládání
17 Presence sensor Датчик движения Czujnik ruchu Sensore di presenza Čidlo přítomnosti
N - Neutral
Entrée
24VAC
24V GND
GND
GND
CAPTEUR
PRÉSENCE
DX GENERAL ERROR
(settable)
DX DEFROST
(settable)
230VAC
GND
21
V+ 0-10 VDC
CO2/RH/VOC/EXT
CO2/ RH/VOC
EXTERNAL
CAPTEUR 0-10V
15VAC
Capteur CO /HR
VDC
0-10
24VAC
Alimentation
vanne
0-10V
Vanne/ Groupe Exterieur DX
Capteur Externe.
Câble deux fils blindé
alimentation générale
Registre
max.1A
max. 50 m
Air Neuf
79 80
70 69 68 67 66 65
81 82 55 56
Registre
Air Rejeté
77 78
23 24
230VAC
POMPE
DE CIRCULATION
76 75
25 26 49 50
59 60
OUTPUT
DX = ON/OFF
(Sortie pour unité
exterieure)
72 71
CONTACT
ERREUR
Commande
á distance
63 64
CONTACT
EXTERNE
ON/OFF
53 54 51 52
CONTACT
INCENDIE
CMSI
62 61
BOOST
BOOST
57 58
boitier de commande
J1/J2
GND GND
1513 14
9
8
7
10
5
4
3
2
1
6
12
11
16 17 18 19 20 21 22 23 24
8283 81 80 79 78 77 76 75 74 73
25 26 27 28 29
68 67 66 65 64 63 62 61 60 59 58 57 56 55 54 53 52 51
31 33 35 36 37 38 39 40 41 42 43
9
44 45 46 47 48 49 5030 32 34
72 71 70 69
GND
N L LO L LO L LO N
GND
GND
0-10V
+SSR -SSR
GND
0-10V
VENT-INT
230VAC
PIR
230VAC
FLAP-INT
230VAC
FLAP-EXT
230VAC
W. PUMP
ALARM
HEATER
RUN
OUTPUT
COOL/HEAT
HEAT PUMP HEAT PUMP
ERROR DEFROST
EXTERNAL
ON/OFF
FIRE BOOST
PRESENCE
SENSOR
PIR
REC ERR
TRANSF-
24VAC
TRANSF-
15VAC
TRANSF-
12VAC
L-VENT
INT-EXT
LN
N
L-TR
N-TR
~
VENT-EXT
HEATER/
COOL/PUMP
PREHEATER
0-10V GND
POSTHEATER
REC/BYP
GNDPWM GNDPWM
RPM
(TC)
RPM 24VAC 24VAC
T-EXT-1 T-EXT-2 T-EXT-3 T-INT-1 T-INT-2
FILTER
INT
T-WATER T-WATER T-ROOM
JP1
LED1
DATA
SWO
TX
RX
-OUT -IN
(TC)
1
~
2
~
1
~
2
15VAC IN GND
CO2/RH/EXT
2
1
12
10
ModBUS RTU via
Rs485
GTC
ou
FUSE
(VENT-EXT)
FUSE
(VENT-INT)
FUSE
(PCB)
FUSE
(PERIPHERY)
!
!
defrost
24VAC
POWER SUPPLY
MIX POINT
MIX. POINT / OUTDOOR
UNIT DX
INPUT
MAIN ELECTRIC SUPPLY
EXT. SENSOR
(two-wire shielded cable)
or
INLET -Fresh air OUTLET DX = ON/OFF
(Output for outdoor unit)
Control panel
EXTERNAL
CONTROL FIRE
WATER
PUMP CONTROL ERROR
CONTACT
PRESENCE
SENSOR
SENSOR
SENSOR
1
5
6
11
17
15 16
23
4712 13 14
8910
E-SCH-RGJ-HR85
3-050-D06378
EN RU PL IT CS
1SMU - power supply Смесительный узел – источник питания Układ mieszający zasilanie Punto di miscelazione - alimentazione SMU - napájení
2Control signal (adjustable: SMU, heater/
cooler)
Управляющий сигнал (регулируемый: SMU,
обогреватель/кулер)
Sygnał sterujący ( do nastawienia : SMU,heater/
cooler)
Segnale di controllo (impostabile: SMU, heater/
cooler)
Řídící signál (nastavitelné: SMU, heater/
cooler)
3Spatial sensor Внутренний датчик Czujnik przestrzenny Sensore ambientale Prostorové čidlo teploty
4Flap - inlet (fresh air) Клапан свежего воздуха Klapa świeżego powietrza Aletta – Aria fresca Klapka pro čerstvý vzduch
5Flap - outlet Клапан отработанного воздуха Klapa wydechu Aletta - Scarico Klapka pro odvodní vzduch
6Water pump Водяной насос (конденсат) Pompa wodna Pompa dell‘acqua Vodní čerpadlo
7RUN function (adjustable in units with direct
evaporator: 0-10V/ON-OFF)
Функция RUN (у модулей с прямым
выпаривателем можно настроить: 0-10V/ON-OFF)
Funkcja RUN (u jednostek z parownikiem bez-
pośrednim do nastawienia : 0-10V/ON-OFF)
Funzione RUN (impostabile per le unità dotate
dell’evaporatore diretto: 0-10V/ON-OFF)
Funkce RUN (nastavitelné s jednotkou s
přímím výparníkem 0-10V / ON/OFF)
8C/O - cooling/heating C/O - охлаждение/ обогрев C/O - chłodzenie / ogrzewanie C/O – raffreddamento/riscaldamento C/O - chlazení/topení
9Direct evaporator - ERROR Прямой выпариватель - ERROR Prosty parownik – ERROR (błąd) Evaporatore diretto – ERROR Přímý výparník - ERROR
10 Direct evaporator - defrost Прямой выпариватель - РАЗМОРОЗКА Prosty parownik - odmrażanie Evaporatore diretto - SCONGELAMENTO Přímý výparník - ODMRAŽOVÁNÍ
11 External control -ON/OFF Внешнее управление Sterowanie zewnętrzne Wł./Wył. Accensione/spegnimento esterno Externí ovládání ON/OFF
12 Alarm - FIRE Пожарный извещатель Wejście stycznika pożarowego Fiamma Poplach - FIRE
13 BOOST regime Функция Boost Funkcja BOOST Boost Režim BOOST
14 Recuperator - ERROR Ошибка рекуператора Usterka rekuperatora Errore – recuperatore Chyba rekuperátoru
15 The air quality sensor - power supply CO2/RH/VOC - источник питания CO2/RH/VOC - zasilanie CO2/RH/VOC - alimentazione Čidlo kvality vzduchu - napájení
16 The air quality sensor - control signal CO2/RH/VOC - данные CO2/RH/VOC - data CO2/RH/VOC - dati Čidlo kvality vzduchu - ovládání
17 Presence sensor Датчик движения Czujnik ruchu Sensore di presenza Čidlo přítomnosti
N - Neutral
Entrée
24VAC
24V GND
GND
GND
CAPTEUR
PRÉSENCE
DX GENERAL ERROR
(settable)
DX DEFROST
(settable)
230VAC
GND
21
V+ 0-10 VDC
CO2/RH/VOC/EXT
CO2/ RH/VOC
EXTERNAL
CAPTEUR 0-10V
15VAC
Capteur CO /HR
VDC
0-10
24VAC
Alimentation
vanne
0-10V
Vanne/ Groupe Exterieur DX
Capteur Externe.
Câble deux fils blindé
alimentation générale
Registre
max.1A
max. 50 m
Air Neuf
79 80
70 69 68 67 66 65
81 82 55 56
Registre
Air Rejeté
77 78
23 24
230VAC
POMPE
DE CIRCULATION
76 75
25 26 49 50
59 60
OUTPUT
DX = ON/OFF
(Sortie pour unité
exterieure)
72 71
CONTACT
ERREUR
Commande
á distance
63 64
CONTACT
EXTERNE
ON/OFF
53 54
51 52
CONTACT
INCENDIE
CMSI
62 61
BOOST
BOOST
57 58
boitier de commande
J1/J2
GND GND
1513 14
9
8
7
10
5
4
3
2
1
6
12
11
16 17 18 19 20 21 22 23 24
8283 81 80 79 78 77 76 75 74 73
25 26 27 28 29
68 67 66 65 64 63 62 61 60 59 58 57 56 55 54 53 52 51
31 33 35 36 37 38 39 40 41 42 43
9
44 45 46 47 48 49 5030 32 34
72 71 70 69
GND
N L LO L LO L LO N
GND
GND
0-10V
+SSR -SSR
GND
0-10V
VENT-INT
230VAC
PIR
230VAC
FLAP-INT
230VAC
FLAP-EXT
230VAC
W. PUMP
ALARM
HEATER
RUN
OUTPUT
COOL/HEAT
HEAT PUMP HEAT PUMP
ERROR DEFROST
EXTERNAL
ON/OFF
FIRE BOOST
PRESENCE
SENSOR
PIR
REC ERR
TRANSF-
24VAC
TRANSF-
15VAC
TRANSF-
12VAC
L-VENT
INT-EXT
LN
N
L-TR
N-TR
~
VENT-EXT
HEATER/
COOL/PUMP
PREHEATER
0-10V GND
POSTHEATER
REC/BYP
GNDPWM GNDPWM
RPM
(TC)
RPM 24VAC 24VAC
T-EXT-1 T-EXT-2 T-EXT-3 T-INT-1 T-INT-2
FILTER
INT
T-WATER T-WATER T-ROOM
JP1
LED1
DATA
SWO
TX
RX
-OUT -IN
(TC)
1
~
2
~
1
~
2
15VAC IN GND
CO2/RH/EXT
2
1
12
10
ModBUS RTU via
Rs485
GTC
ou
FUSE
(VENT-EXT)
FUSE
(VENT-INT)
FUSE
(PCB)
FUSE
(PERIPHERY)
!
!
defrost
24VAC
POWER SUPPLY
MIX POINT
MIX. POINT / OUTDOOR
UNIT DX
INPUT
MAIN ELECTRIC SUPPLY
EXT. SENSOR
(two-wire shielded cable)
or
INLET -Fresh air OUTLET DX = ON/OFF
(Output for outdoor unit)
Control panel
EXTERNAL
CONTROL FIRE
WATER
PUMP CONTROL ERROR
CONTACT
PRESENCE
SENSOR
SENSOR
SENSOR
1
5
6
11
17
15 16
23
4712 13 14
8910
E-SCH-RGJ-HR85
3-050-D06378
44 43
17 19
18 20
2
3 4 5 6 7 8
9
11
1
EN RU PL IT CS
1SMU - power supply Смесительный узел – источник питания Układ mieszający zasilanie Punto di miscelazione - alimentazione SMU - napájení
2Control signal (adjustable: SMU, heater/
cooler)
Управляющий сигнал (регулируемый: SMU,
обогреватель/кулер)
Sygnał sterujący ( do nastawienia : SMU,heater/
cooler)
Segnale di controllo (impostabile: SMU, heater/
cooler)
Řídící signál (nastavitelné: SMU, heater/
cooler)
3Spatial sensor Внутренний датчик Czujnik przestrzenny Sensore ambientale Prostorové čidlo teploty
4Flap - inlet (fresh air) Клапан свежего воздуха Klapa świeżego powietrza Aletta – Aria fresca Klapka pro čerstvý vzduch
5Flap - outlet Клапан отработанного воздуха Klapa wydechu Aletta - Scarico Klapka pro odvodní vzduch
6Water pump Водяной насос (конденсат) Pompa wodna Pompa dell‘acqua Vodní čerpadlo
7RUN function (adjustable in units with direct
evaporator: 0-10V/ON-OFF)
Функция RUN (у модулей с прямым
выпаривателем можно настроить: 0-10V/ON-OFF)
Funkcja RUN (u jednostek z parownikiem bez-
pośrednim do nastawienia : 0-10V/ON-OFF)
Funzione RUN (impostabile per le unità dotate
dell’evaporatore diretto: 0-10V/ON-OFF)
Funkce RUN (nastavitelné s jednotkou s
přímím výparníkem 0-10V / ON/OFF)
8C/O - cooling/heating C/O - охлаждение/ обогрев C/O - chłodzenie / ogrzewanie C/O – raffreddamento/riscaldamento C/O - chlazení/topení
9Direct evaporator - ERROR Прямой выпариватель - ERROR Prosty parownik – ERROR (błąd) Evaporatore diretto – ERROR Přímý výparník - ERROR
10 Direct evaporator - defrost Прямой выпариватель - РАЗМОРОЗКА Prosty parownik - odmrażanie Evaporatore diretto - SCONGELAMENTO Přímý výparník - ODMRAŽOVÁNÍ
11 External control -ON/OFF Внешнее управление Sterowanie zewnętrzne Wł./Wył. Accensione/spegnimento esterno Externí ovládání ON/OFF
12 Alarm - FIRE Пожарный извещатель Wejście stycznika pożarowego Fiamma Poplach - FIRE
13 BOOST regime Функция Boost Funkcja BOOST Boost Režim BOOST
14 Recuperator - ERROR Ошибка рекуператора Usterka rekuperatora Errore – recuperatore Chyba rekuperátoru
15 The air quality sensor - power supply CO2/RH/VOC - источник питания CO2/RH/VOC - zasilanie CO2/RH/VOC - alimentazione Čidlo kvality vzduchu - napájení
16 The air quality sensor - control signal CO2/RH/VOC - данные CO2/RH/VOC - data CO2/RH/VOC - dati Čidlo kvality vzduchu - ovládání
17 Presence sensor Датчик движения Czujnik ruchu Sensore di presenza Čidlo přítomnosti
N - Neutral
Entrée
24VAC
24V GND
GND
GND
CAPTEUR
PRÉSENCE
DX GENERAL ERROR
(settable)
DX DEFROST
(settable)
230VAC
GND
21
V+ 0-10 VDC
CO2/RH/VOC/EXT
CO2/ RH/VOC
EXTERNAL
CAPTEUR 0-10V
15VAC
Capteur CO /HR
VDC
0-10
24VAC
Alimentation
vanne
0-10V
Vanne/ Groupe Exterieur DX
Capteur Externe.
Câble deux fils blindé
alimentation générale
Registre
max.1A
max. 50 m
Air Neuf
79 80
70 69 68 67 66 65
81 82 55 56
Registre
Air Rejeté
77 78
23 24
230VAC
POMPE
DE CIRCULATION
76 75
25 26 49 50
59 60
OUTPUT
DX = ON/OFF
(Sortie pour unité
exterieure)
72 71
CONTACT
ERREUR
Commande
á distance
63 64
CONTACT
EXTERNE
ON/OFF
53 54
51 52
CONTACT
INCENDIE
CMSI
62 61
BOOST
BOOST
57 58
boitier de commande
J1/J2
GND GND
1513 14
9
8
7
10
5
4
3
2
1
6
12
11
16 17 18 19 20 21 22 23 24
8283 81 80 79 78 77 76 75 74 73
25 26 27 28 29
68 67 66 65 64 63 62 61 60 59 58 57 56 55 54 53 52 51
31 33 35 36 37 38 39 40 41 42 43
9
44 45 46 47 48 49 5030 32 34
72 71 70 69
GND
N L LO L LO L LO N
GND
GND
0-10V
+SSR -SSR
GND
0-10V
VENT-INT
230VAC
PIR
230VAC
FLAP-INT
230VAC
FLAP-EXT
230VAC
W. PUMP
ALARM
HEATER
RUN
OUTPUT
COOL/HEAT
HEAT PUMP HEAT PUMP
ERROR DEFROST
EXTERNAL
ON/OFF
FIRE BOOST
PRESENCE
SENSOR
PIR
REC ERR
TRANSF-
24VAC
TRANSF-
15VAC
TRANSF-
12VAC
L-VENT
INT-EXT
LN
N
L-TR
N-TR
~
VENT-EXT
HEATER/
COOL/PUMP
PREHEATER
0-10V GND
POSTHEATER
REC/BYP
GNDPWM GNDPWM
RPM
(TC)
RPM 24VAC 24VAC
T-EXT-1 T-EXT-2 T-EXT-3 T-INT-1 T-INT-2
FILTER
INT
T-WATER T-WATER T-ROOM
JP1
LED1
DATA
SWO
TX
RX
-OUT -IN
(TC)
1
~
2
~
1
~
2
15VAC IN GND
CO2/RH/EXT
2
1
12
10
ModBUS RTU via
Rs485
GTC
ou
FUSE
(VENT-EXT)
FUSE
(VENT-INT)
FUSE
(PCB)
FUSE
(PERIPHERY)
!
!
defrost
24VAC
POWER SUPPLY
MIX POINT
MIX. POINT / OUTDOOR
UNIT DX
INPUT
MAIN ELECTRIC SUPPLY
EXT. SENSOR
(two-wire shielded cable)
or
INLET -Fresh air OUTLET DX = ON/OFF
(Output for outdoor unit)
Control panel
EXTERNAL
CONTROL FIRE
WATER
PUMP CONTROL ERROR
CONTACT
PRESENCE
SENSOR
SENSOR
SENSOR
1
5
6
11
17
15 16
23
4712 13 14
8910
E-SCH-RGJ-HR85
3-050-D06378
56 55
0-10V
GND
24V
+
GND
-
10
EN RU PL IT CS
1SMU - power supply Смесительный узел – источник питания Układ mieszający zasilanie Punto di miscelazione - alimentazione SMU - napájení
2Control signal (adjustable: SMU, heater/
cooler)
Управляющий сигнал (регулируемый: SMU,
обогреватель/кулер)
Sygnał sterujący ( do nastawienia : SMU,heater/
cooler)
Segnale di controllo (impostabile: SMU, heater/
cooler)
Řídící signál (nastavitelné: SMU, heater/
cooler)
3Spatial sensor Внутренний датчик Czujnik przestrzenny Sensore ambientale Prostorové čidlo teploty
4Flap - inlet (fresh air) Клапан свежего воздуха Klapa świeżego powietrza Aletta – Aria fresca Klapka pro čerstvý vzduch
5Flap - outlet Клапан отработанного воздуха Klapa wydechu Aletta - Scarico Klapka pro odvodní vzduch
6Water pump Водяной насос (конденсат) Pompa wodna Pompa dell‘acqua Vodní čerpadlo
7RUN function (adjustable in units with direct
evaporator: 0-10V/ON-OFF)
Функция RUN (у модулей с прямым
выпаривателем можно настроить: 0-10V/ON-OFF)
Funkcja RUN (u jednostek z parownikiem bez-
pośrednim do nastawienia : 0-10V/ON-OFF)
Funzione RUN (impostabile per le unità dotate
dell’evaporatore diretto: 0-10V/ON-OFF)
Funkce RUN (nastavitelné s jednotkou s
přímím výparníkem 0-10V / ON/OFF)
8C/O - cooling/heating C/O - охлаждение/ обогрев C/O - chłodzenie / ogrzewanie C/O – raffreddamento/riscaldamento C/O - chlazení/topení
9Direct evaporator - ERROR Прямой выпариватель - ERROR Prosty parownik – ERROR (błąd) Evaporatore diretto – ERROR Přímý výparník - ERROR
10 Direct evaporator - defrost Прямой выпариватель - РАЗМОРОЗКА Prosty parownik - odmrażanie Evaporatore diretto - SCONGELAMENTO Přímý výparník - ODMRAŽOVÁNÍ
11 External control -ON/OFF Внешнее управление Sterowanie zewnętrzne Wł./Wył. Accensione/spegnimento esterno Externí ovládání ON/OFF
12 Alarm - FIRE Пожарный извещатель Wejście stycznika pożarowego Fiamma Poplach - FIRE
13 BOOST regime Функция Boost Funkcja BOOST Boost Režim BOOST
14 Recuperator - ERROR Ошибка рекуператора Usterka rekuperatora Errore – recuperatore Chyba rekuperátoru
15 The air quality sensor - power supply CO2/RH/VOC - источник питания CO2/RH/VOC - zasilanie CO2/RH/VOC - alimentazione Čidlo kvality vzduchu - napájení
16 The air quality sensor - control signal CO2/RH/VOC - данные CO2/RH/VOC - data CO2/RH/VOC - dati Čidlo kvality vzduchu - ovládání
17 Presence sensor Датчик движения Czujnik ruchu Sensore di presenza Čidlo přítomnosti
N - Neutral
Entrée
24VAC
24V GND
GND
GND
CAPTEUR
PRÉSENCE
DX GENERAL ERROR
(settable)
DX DEFROST
(settable)
230VAC
GND
21
V+ 0-10 VDC
CO2/RH/VOC/EXT
CO2/ RH/VOC
EXTERNAL
CAPTEUR 0-10V
15VAC
Capteur CO /HR
VDC
0-10
24VAC
Alimentation
vanne
0-10V
Vanne/ Groupe Exterieur DX
Capteur Externe.
Câble deux fils blindé
alimentation générale
Registre
max.1A
max. 50 m
Air Neuf
79 80
70 69 68 67 66 65
81 82 55 56
Registre
Air Rejeté
77 78
23 24
230VAC
POMPE
DE CIRCULATION
76 75
25 26 49 50
59 60
OUTPUT
DX = ON/OFF
(Sortie pour unité
exterieure)
72 71
CONTACT
ERREUR
Commande
á distance
63 64
CONTACT
EXTERNE
ON/OFF
53 54 51 52
CONTACT
INCENDIE
CMSI
62 61
BOOST
BOOST
57 58
boitier de commande
J1/J2
GND GND
1513 14
9
8
7
10
5
4
3
2
1
6
12
11
16 17 18 19 20 21 22 23 24
8283 81 80 79 78 77 76 75 74 73
25 26 27 28 29
68 67 66 65 64 63 62 61 60 59 58 57 56 55 54 53 52 51
31 33 35 36 37 38 39 40 41 42 43
9
44 45 46 47 48 49 5030 32 34
72 71 70 69
GND
N L LO L LO L LO N
GND
GND
0-10V
+SSR -SSR
GND
0-10V
VENT-INT
230VAC
PIR
230VAC
FLAP-INT
230VAC
FLAP-EXT
230VAC
W. PUMP
ALARM
HEATER
RUN
OUTPUT
COOL/HEAT
HEAT PUMP HEAT PUMP
ERROR DEFROST
EXTERNAL
ON/OFF
FIRE BOOST
PRESENCE
SENSOR
PIR
REC ERR
TRANSF-
24VAC
TRANSF-
15VAC
TRANSF-
12VAC
L-VENT
INT-EXT
LN
N
L-TR
N-TR
~
VENT-EXT
HEATER/
COOL/PUMP
PREHEATER
0-10V GND
POSTHEATER
REC/BYP
GNDPWM GNDPWM
RPM
(TC)
RPM 24VAC 24VAC
T-EXT-1 T-EXT-2 T-EXT-3 T-INT-1 T-INT-2
FILTER
INT
T-WATER T-WATER T-ROOM
JP1
LED1
DATA
SWO
TX
RX
-OUT -IN
(TC)
1
~
2
~
1
~
2
15VAC IN GND
CO2/RH/EXT
2
1
12
10
ModBUS RTU via
Rs485
GTC
ou
FUSE
(VENT-EXT)
FUSE
(VENT-INT)
FUSE
(PCB)
FUSE
(PERIPHERY)
!
!
defrost
24VAC
POWER SUPPLY
MIX POINT
MIX. POINT / OUTDOOR
UNIT DX
INPUT
MAIN ELECTRIC SUPPLY
EXT. SENSOR
(two-wire shielded cable)
or
INLET -Fresh air OUTLET DX = ON/OFF
(Output for outdoor unit)
Control panel
EXTERNAL
CONTROL FIRE
WATER
PUMP CONTROL ERROR
CONTACT
PRESENCE
SENSOR
SENSOR
SENSOR
1
5
6
11
17
15 16
23
4712 13 14
8910
E-SCH-RGJ-HR85
3-050-D06378
14 13
M
A
G
A shielded cable (e.g. UTP
type) is recommended for
the connection of the control
panel to the unit (Cat5e).
AElectronic board - Module A
GElectronic board - Module G
1Room temperature sensor (CT-ROOM, input)
2CO2sensor, data input (0-10V, input)
3RUN contact (relay, adjustable, max. 2A)
4ERROR contact (relay, error = ON, OK = switched off, max. 2A)
5BOOST button (input button)
6PIR input sensor or FIRE alarm (input, adjustable)
7External control input (input, connected = ON, disconnected = OFF)
8Output for SMU actuator (output, 0-10V), only in version with WPOH
9Control panel (must be connected – cable not included)
10 24V power supply for the mixing junction or specic components (output)
11 Circulation pump (relay max. 2A)
16
INSTRUCTION MANUAL
Susurr
TM

CONTROL
Check the following before switching on the unit for the rst time:
• That the unit is properly closed and all the outlets are connected to the ductwork.
• That the electric connection matches the diagram, including earthing and protection of external circuits.
• That all the electric components are properly connected.
• That the condensate drain is connected to the sewage
• That the installation corresponds to the instructions in the manual.
• That no tools or objects that may damage the unit have been left inside.
• That the lters are clean
CAUTION!
• Alterations and changes to the internal connections of the unit are forbidden and may result in the loss of warranty.
• We recommend the use of accessories provided by our company. Contact your supplier in case of doubts with the use of
non-original accessories.
INITIAL COMMISSIONING
• After connecting the unit, the display lights up and the data
is loaded. The service data begins to load. Once it has fully
loaded, the unit is ready for start-up.
• The remote control has a touch-screen – the unit is controlled
touching the symbols on the screen.
Switching the unit to
stand-by mode
Activate boost mode
Unit's time switch
Displays current temperature,
ventilation rate, CO2 concentration,
ventilation date and mode
Ventilation rate settings
Required temperature
settings
Password lock
Detailed information
on ventilation status
Unit’s settings
(Service menu)
Start-up:
INFORMATION ON THE VENTILATION
STATUS
Back
This screen shows the status of the unit and the values of
the sensors::
• Current air ow of both fans
• Inlet and exhaust air temperature
• Status of the heat exchanger bypass
• Performance of the electric preheating and reheating
• Values of the connected air quality sensor
Information on
the type of unit
Occupancy mode active
The timer is active
The cooling is active
(with a graphic
indication of the
remaining time)
30% 30%
17
© Airow - All rights reserved
INSTRUCTION MANUAL
Susurr
TM

20%
Unit's time switch Enable / disable timer
Weekly mode
Annual mode
Touch a day to set ventilation modes
Touch to set ventilation time modes
Annual mode
Weekly mode
Back Delete time interval
End of time interval
Start of time interval
Switch to manual or
automatic mode
Add a time
mode
In manual mode, in addition to the temperature, you can also
set the ventilation rate.
when the time interval ends, the unit goes into stand-by mode
UNIT SETTINGS
Required
temperature
settings
Ventilation rate
settings
Language settings
Display settings
Unit's service settings
Date and time
NFC
Unit's time
switch
Back
Ventilation rate settings
Display required air ow
Reduce or
increase the
unit's air ow
Display
current air
ow
Required temperature settings
Reduce or
increase
required
temperature
Display
current
temperature
(at selected
sensor)
Display required temperature
18
INSTRUCTION MANUAL
Susurr
TM

06 - Filter timer
23 - User lock
50 - Factory reset
Language settings
Display settings
Brightness
when using
Brightness
in stand-by
mode
NFC SETTINGS
In the NFC menu you can display the
information after placing an NFC compatible
mobile device.
TIME AND DATE SETTINGS
SERVICE MENU
Enter code 1616 to access the service menu
MENU 01 - MODE
Scroll to select menu
Access selected
menu
Manual
ventilation
mode
Ventilation
according to
the require-
ments of the
air quality
sensor
MANUAL:
The unit ventilates according to the selected rate
DCV:
The unit ventilates according to the requirements of the air quality sensor,
e.g.: CO2, RH (0-10V control signal)
06 - Filter timer
23 - User lock
50 - Factory reset
19
© Airow - All rights reserved
INSTRUCTION MANUAL
Susurr
TM

MENU 02 - HW SETTING
MENU 06 - FILTER TIMER
06 - Filter timer
50 - Factory reset
08 - AQS Sensor
Digital input (15-16)
re input You can choose
the logic of the
RUN contact
You can choose the
contact to switch the
PIR sensor or the
FIRE contact
This menu lets you set the logic using the digital input and RUN output.
• Input (15-16) – Lets you choose to control the unit with the movement
sensor or as a re contact. In case of re, the behavior of the unit can
be set (settings in service menu no. 09)
• Output (7-8) – Lets you set the logic of the RUN contact switch as
follows: N.close (normally closed) or N.Open (normally open)
Status to notify
lter clogging
control
Set the
maximum
number of hours
to notify lter
clogging control
(depends on the
environment of
the installation)
Reset lter
clogging control
timer (use when
changing the
lter)
MENU 07-EXCHANGERS
03 - Filter timer
04 - AQS Sensor
05 - Temperature sensor
06
08
09
Preheating:
No
Electric
Water
Reheating:
No
Electric
Water
Change over
Direct vaporizer
20
INSTRUCTION MANUAL
Susurr
TM
Other manuals for Susurro 400
1
This manual suits for next models
2
Table of contents
Other Airflow Heating System manuals
Popular Heating System manuals by other brands

STIEBEL ELTRON
STIEBEL ELTRON WPKI-HKM E Installation

BLAUBERG Ventilatoren
BLAUBERG Ventilatoren HRV H 200 Operation manual

therm-ic
therm-ic Integration Mono button BLE manual

Dimplex
Dimplex TIMRA Installation and operating instructions

Warmup
Warmup StickyMat 3D installation manual

BLAUBERG Ventilatoren
BLAUBERG Ventilatoren VENTO Ergo A50 Pro Operation manual