AirPhysio OPEP User manual

Oscillating Positive Expiratory Pressure Therapy
OPEP Mucus Clearance and
Lung Expansion Device
5. Once your lungs are at optimal lung capacity to lift
the ball bearing, adjust tilt to feel maxium vibrations
within your chest and keep cheeks stiff. If the ball bearing is not moving
this is normal for some people starting out. Continue using
until lung strength improves over time.
The device can also be used as an adjunctive therapy to
prevent pulmonary complications in patients after surgery (i.e. cardiac and
abdominal surgeries). The use of the device facilitates secretion
mobilization, prevents atelectasis, and increases lung volume of patients
postoperatively.
is a drug-free handheld lung physiotherapy device. It uses an
all natural Oscillating Positive Expiratory Pressure (OPEP) process to create
pressure and vibration causing the mucus to loosen and move progressively
up the airways, to the throat, until it can be coughed out or swallowed.
The device also assists to increase lung capacity and open
blocked and semi-closed airways. OPEP therapy has proven to be an
effective means of clearing the airway for individuals with any of the
following respiratory conditions:
Asthma;
Atelectasis:
Bronchiectasis;
Chronic Obstructive Pulmonary Diseases (COPDs), such as Chronic
Bronchitis and Emphysema;
Cystic Fibrosis;
Other conditions producing retained secretions.
How Often to Use
Use the device for up to 10 mins, once or twice a day when symtoms show
or as required. To maintain lung hygiene and maximum lung capacity, use
at least once per week after symptoms cease, as this will help maintain
better breathing.
When you exhale through the device, a positive pressure is created in
your lungs which will assist in strenghtening and lung expansion. This
pressure is created, even when the steel ball is not moving. As your lung
strength increases, your breath will move the steel ball bearing, lifting it
above the cone, breaking the seal between the cone and the ball bearing.
The steel ball bearing movement creates an oscillating pressure to assist
in vibration of the airways which will further assist to loosen mucus from
the airway walls.
6. After exhaling through the device, you may feel mucus accumulating at the
back of your throat. If so, initiate a cough to expel the mucus. If not the
has started this process and the mucus will continue working
up to the throat (even after 5-10 minutes use). And you may swallow
the mucus as the mucus is expelled, as per normal bodily processes.
3. Hold breath for 2 to 3 seconds.
2. Slowly inhale beyond a normal breath, but do
not fill lungs completely.
This method may make you feel lightheaded. This is normal due
to the amount of carbon dioxide being exhaled. When you feel lightheaded,
take a break and breathe normally until the lightheaded feeling passes. If you
try to overexert and push yourself too far, there is a chance that you may pass
out and lose consciousness.
Results from the use of device may be different
person to person, based on their physical fitness, severity of mucus clearance
issues and pre-existing medical conditions.
Place the
device in mouth, exhale
through the device at a reasonably fast rate but
not too forcefully, using abdominal/deep
breathing. Do not empty the lungs and use lip
balm if your lips dry out in the process.
How Does Work?
How to Use Device:
1. Gather a glass of water and box of tissues,
relax and assume a proper sitting or standing
posture.
4.
7.
Repeat steps 2 through 4 for up to 10 minutes. Feel free to stop and relax while
taking deep breaths to prevent light headedness. Begin again when ready.
Caution:
Disclaimer:

Warning: Chlorine bleach or other products containing chlorine (eg dishwashing
detergent) should not be used for cleaning the device
How Do I Clean the Device?
Cautions and Warnings
Storage Conditions
Store in a cool dry place outside of direct sunlight
Device Components of
Thanks for buying from us
As a small boutique company from Australia, we pride ourselves on our
innovative, life changing products, and our wish is that it brings you improved
activity and performance results through better breathing.
Did you have any problems?
If something is not right with your product, please email us on
info @airphysio.com. Make sure you tell us the purchase details and a picture
of the problem that really helps.
A small favor if you purchased online...
If you purchased online, please consider leaving a review. We really do
appreciate your time.
Register for our 12-Month Free Warranty
We stand by our products and offer an extended 12-month warranty
provided you purchased it directly from us or our Authorized Agent.
Please make sure you register to ensure you take advantage of this
offer. In the unlikely event of a problem, we will either pay the shipping
back to us for repair or replace it for you.
Thanks again for trusting us with your purchase. We’re here 7- days a
week, so we promise a quick reply.
Email: [email protected]
Contraindications:
Untreated pneumothorax;
Tuberculosis;
Hemoptysis (coughing up blood)
Oesophageal surgery;
Right-sided heart failure;
Middle ear pathology, i.e ruptured tympanic membrane.
Please consult your doctor if you have any of the following
Conditions prior to using the device.
Keep out of the reach of children and do not allow the device
to be used by unsupervised chrildren. The device is designed to be pulled
apart for cleaning and therefore the internal parts can become choking hazards.
Caution: Choking Hazard
There are 2 ways to clean your device- A) Assembled or B) Disassembled.
Cleaning your device is good for hygiene and the prevention of spreading
bacteria and germs. Most people find it necessary to clean the device after
each session to remove moisture and/or mucus from the internal components.
A) Assembled
1. Wash in a solution of water with mild soap or disinfectant solution
2. Rinse and allow to air dry and/or shake to assist removing excess water
3. Place in a drying tray with the mouthpiece facing down to allow water to
drain away and dry
4. Allow the device to dry in the open at room temperature
B) Disassembled
1. Disassemble the device as per the above instructions ‘How to unlock
the child resistant clear top cap’
2. Wash in a solution of water with mild soap or disinfectant solution
3. Rinse and allow all the components to dry in the open at room temperature
4. Reassemble device & store in a clean, dry location
AirPhysio Pty Ltd
ABN 84607523697
Shop 3/47 Tweed Coast Road, Bogangar, NSW 2488
Ph: +61 1300 257 710 / Int’l: +61 7 3535 0604
www.airphysio.com
1 x Child Resistant cover (Poly-Carbonate Plastic)
1 x Mouthpiece and Base with inbuilt Cone (Poly-Carbonate Plastic)
1 x Ball Bearing (Stainless Steel)
How to Unlock the Child-Resistant Clear Top Cap
1. Grasp the clear cap with one hand and the body with the other hand
2. Twist the cap 0.3” anti-clockwise (note: the cap may be stiff when twisting,
(as to deter children from opening the device)
3. Lift the clear cap from the body of the device and disassemble for cleaning
4. Pull clear cap away from blue body
Step 1 Step 2 Step 3 Step 4
Table of contents
Other AirPhysio Medical Equipment manuals
Popular Medical Equipment manuals by other brands

Defibtech
Defibtech Lifeline/ReviveR ECG+ DDU-2475 user manual

Cardinal Health
Cardinal Health Kangaroo Omni 385400 Instructions for use

SonoSite
SonoSite V-UNIVERSAL STAND user guide

Mindray
Mindray A8 operating instructions

Dentsply Sirona
Dentsply Sirona TENEO Installation requirements

rehamedi
rehamedi Medior Instructions for use

Sensa Core
Sensa Core Hemo Spark user manual

vita
vita Easyshade operating manual

Omron
Omron Large Cuff manual

Sunrise Medical
Sunrise Medical DeVilbiss RPM AutoAdjust 9054 Series Instruction guide

WISAP
WISAP Cervix Coagulator user manual

Ultrasound Technologies
Ultrasound Technologies Fetatrack 310 Service manual