SM DLF1-A.1
GB
2-1
PRODUCT DATA SHEET
2.1 DLF18 DCI
Model Indoor Unit AWSI-DLF018 –N11
Model Outdoor Unit AWAU-YBDE018-H11
Installation Method DUCTED
Characteristics Units Cooling Heating
Average Warmer
Pdesign kW 5.0 4.8 4.8
SEER / SCOP (1) W/W 5.43.9 4.3
Energy efficiency class AA A+
Annual energy consumption kWh 808 2549 1488
Tbiv oC N/A -3 6
Tol oC N/A -15 -15
Capacity Range (1) (min÷max) kW 1.5÷5.81.3÷6.8
Power supply V/Ph/Hz 220-240V/Single/50Hz
Circuit breaker rating A 20
INDOOR
Fan type & quantity Centrifugal x 2
Fan speeds H/M/L RPM 1110/980/860
Air flow (2) H/M/L m3/hr 710/600/540
External static pressure Min-Max Pa 0-40
Sound power level (3) H/M/L dB(A) 54/51/48
Sound pressure level (4) H/M/L dB(A) 35/32/29
Moisture removal l/hr 1.8
Condensate drain tube I.D mm 19
Dimensions WxHxD mm 750x630x200
Weight kg 21
Package dimensions WxHxD mm 890x710x243
Packaged weight kg 23
Units per pallet units 14
Stacking height units 7
OUTDOOR
Refrigerant control EEV
Compressor type, model Twin Rotary DC Inverter
Fan type & quantity Axial x 1
Fan speeds RPM 200 – 750 (continuous)
Air flow Max. m3/hr 2500
Sound power level Nom. dB(A) 65
Sound pressure level Nom. dB(A) 53
Dimensions WxHxD mm 900x700x340
Weight kg 56
Package dimensions WxHxD mm 985x730x435
Packaged weight kg 58.5
Units per pallet Units 6 units per pallet
Stacking height units 2 levels
Refrigerant type R410A
Refrigerant charge (standard connecting tubing
length) kg(7.5m) 1.55
Additional charge per 1 meter gr / 1m 7.5m < 0gr < 15m < 35gr per 1m < 30m
Connections between
units
Liquid line In.(mm) 1/4"(6.35)
Suction line In.(mm) 1/2"(12.7)
Max. tubing length m. 30
Max. height difference m. 15
Operation control type Remote control
Heating elements kW
Others
(1) Rating conditions in accordance with EN14825 and EN14511 (for ducted units).
(2) Airflow in ducted units; at nominal external static pressure.
(3) Sound power in ducted units is measured at air discharge.
(4) Sound pressure level measured at 1.4 meter distance from unit.
2. PRODUCT