2. When the signal line without shielding is used, there will be interference signals entering
the power amplifier for amplification. It is recommended that you replace the signal line
with shielding.
3. There is still noise after troubleshooting the above two points,Please confirm the noise
is from the external or the internal. Disconnect all inputs, only retain the power supply
and output cable, if the noise disappears, that means the noise is from the audio input.
If the noise is still there, the noise may be caused by interference with the power supply
or generated inside the amplifier.
A: 1. Please check the audio source has been turned on and the volume is not at the minimum.
2. Please confirm whether the speaker and amplifier match ( For example, the speaker is
fixed resistance or fixed voltage, the power of speaker is too much over the power of the
amplifier etc).
Q: Why there is no sound or very little sound after the amplifier is connected
to the speaker?
A: Please check audio source, input cable, volume potentiometer (some amplifiers have
balanced control or separate volume control of left and right channel ), speaker cable,
speakers (whether the position and the distance is symmetrical) and other factors.
Q: What are the reasons for the unbalanced left and right volume of the s
peakers and how to eliminate them?
A: Please confirm the on-off sequence is correct, normally it follows the order of signal
transmission when turn on: audio source → preamp / DAC → amplifier → speaker. (The
sequence is reversed when switching off. As the internal capacitors will be discharged for a
while after shutdown. If turn off the preamp firstly and then turn off amplifier, impact
sound will be easily caused which may damage the amplifier or speaker in severe cases).
Q: Why is there a thumping sound when swithing on/off?
7 8
Shenzhen Yima Technology Co.,Ltd
Product Warranty
If you have any questions about the goods you received, please contact us
online within 48 hours Customer service. If the product has quality problems
and needs to be repaired or returned, please fill in this card truthfully.
Username:
Contact number:
Date of purchase:
Product number:
Note: The product warranty is 1 year
Maintenance failure:
Warning
1. Please do not open the shell without permission. Improper operation may cause the
danger of electric shock.
2. Please use the power supply of the regular manufacturer, otherwise it will damage the
machine.
3. Please do not use the machine in a high temperature and humidity environment.