Aleko LM178 User manual

User Manual
Wat er p r oof
Du al -r el ay Ac c es s Con tr ol
2. Descr i pt ion
The LM177/LM178is a two relays multifunction standalone
access controller. It is suitable for mounting either indoor or
outdoor in harsh environments. It is housed in a strong,
sturdy and vandal proof zinc alloy electroplated case. The
electronics are fully potted so the is waterproof
and conforms to IP68.
It supports up to 1200 users in either a Card, PIN, or a Card +
PIN option. The built-in card reader supports 125KHz EM
frequency card, and the PIN length is 4-8 digits.
Both of the two relays on board can operate in Pulse Mode
(suitable for access control) or Toggle Mode (suitablefor arming/
disarming alarms,switching lights, machines....etc)
W1-A/W3-A is an ideal choice for door access not only for
small shops and domestic households but also for
commercial and industrial applications such as factories,
warehouses, laboratories, banks and prisons.
(
LM178
are in the same function, only different in shape. )
3. Feat u r es
> Waterproof, conforms to IP68
> Strong zinc alloy electroplated anti- vandal case
> Two- relay operation
> B oth of t he 2 relays can be programmed for 3 m odes:
Card, PIN, Card + P IN
> 1 200 users
> Z one 1: up to 1100 PIN & Card holders
> Z one 2: up to 100 PIN & Card holders
1. Pac k ing L i st
Name Remark
Screw Driver
Rubber Bungs
SelfTapping Screws
1
4
4
6*27mm, used for fixing
User Manual 1
1
Please ensure that all the above contents are correct. If any are
missing please notify the supplier of the LM178.
Digital Keypad LM178
Quantity
3.5*27mm, used for fixing
LM178
LM178
www.AlekoProducts.com

5. Inst allat ion
> PIN length: 4- 8 digits; Card type: 125KHz EM card
> Can be used as a stand alone keypad
> Pulse mode, Toggle mode
> B lock enrollment, can enroll 1100 consecutive cards
within 1 minute
> B acklight keypad
> Adjustable door relay output time, alarm time, door open
time
> B uilt in light dependent resistor (LDR) for anti tamper
> B uilt in buzzer
> Two- relay output for door opening, door status detecting,
open door by button
> Red, yellow and green LED display the working status
> Support door bell connection(Zone 2)
> 1 2- 24V DC/12-18V AC power input
> Two- year warranty
4. Specifications
Operating Humidity
Environment
Adjustable Door Relay time
Adjustable Alarm Time
Wiring Connections
5%- 9 5% RH
Conforms to IP68
1- 99 seconds
0- 3 m inutes
Electric Lock,Exit Button,
DOTL, Ext er nal Alar m
Operating Temperature -40℃- 60℃
Operating Voltage
User Capacity
Keypad
Card Type
Card Reading Distance
PIN length
Active Current
Idle Current
Lock Output Load
Alarm Output Load
12-24V DC/ 12-18VAC
1200
EM card
3- 6 cm
4- 8 digits
60mA
25± 5 m A
Max 20A
Max 2A
Dimensions
Net Weight
Gross Weight
650 g
800 g
L128xW82 x H28 mm (
LM178
)
> Remove the back cover from the keypad using the
supplied security screwdriver
> Drill four holes on the wall for the screws and 1 hole for
the cable
> Fix the back cover firmly on the wall with 4 flat head
screws
> Thread the cable through the cable hole
> Use the supplied rubber bungs to waterproof the screw
holes
> Attach the keypad to the back cover
Negative Pole
Alarm Negative
Request to Exit Button of Zone 1
Door Status Detecting
12-24V DC/12-18V AC Power Input
12-24V DC/12-18V AC Power Input
Request to Exit Button of Zone 2
Grey & Black
Grey
Yellow
Brown
Red
Black
Blue& Black
White&Black
White
Yellow & Black
Green& Black
Blue
Green
GND
Alarm -
OPEN1
D_IN
AC&DC
AC&DC
NO2
COM2
COM1
OPEN2
NC2
NO1
NC1
6. Wiring
Colour Function Description
12 keys, 3 x4 digits ( )
LM178
LM178

Connection Diagram
12-24V DC/ 12-18VAC/5A
Power
-
+
+
-
Alar m
Door Stat us Detec ting
Door Bell
Request to Exit Button of Zone 2
Request to Exit Button of Zone 1
Electric Lock Diode
NO 2 Wh ite
COM 2( Green/White)
Door Bell i nstallation & usage:
Connect door bell w ith wir es:NO2 COM2 .
Press ‘ #’ ,the W1- A/ W3- A reader will
send outa signal to the door b ell.
Remarks:
The Zone 2, it can be used to operate the door bell when no
need to operate a second door. The wiring is connecting the
door bell to NO2 and COM2. Press #, the reader will send
out a switching signal to the door bell, as long as you press
the “ #” , the door bell will continuous operate, it will stop
until you release the “ #”
Connect the negative pole of the lock to NC is for Fail safe
lock.
Connect the negative pole of the lock to NO is for Fail secure
lock.
LM178
Yellow OPEN1
Brown D_ IN
Red
Black
AC&DC
AC&DC
Blue & Black NO2
Green & Black
2MOC& kcalBetihW
NC2
Blue NO1
2NEPO& kcalBwolleY
Grey&Black GND
ALARM
NC1
COM1
Green
White
Grey
Yellow OPEN1
Brow n D_ IN
Red
Black
AC&DC
AC&DC
Blue & Black NO2
Green & Black
2MOC& kcalBetihW
NC2
Blue NO1
2NEPO& kcalBwolleY
Grey&Black GND
ALARM
NC1
COM1
Green
White
Grey
1 2 3 4 5 6 7 8 9
10 11 12
+ MOTOR1 - ULT1 COM DLT1 + MOTOR2 - ULT2 COM DLT2 + LAMP -
13 14 15 16 17 18 19
20
+ BAT - PHOTOCELL O/S/C
INC FUNC DEC
LEARN
AS & GateGuard Series
2
1
L N
PWRIN
43
VU
5
W
76
LAMP
98
COM DWN
10
UP
12
11
COM PHO
13
O/S/C
OPLD
CLLD
GND
14
AC1500, AR1550, AC2400, AR2450, AC5700,AR5750
Yellow OPEN1
Brown D_ IN
Red
Black
AC&DC
AC&DC
Blue & Black NO2
Green & Black
2MOC& kcalBetihW
NC2
Blue NO1
2NEPO& kcalBwolleY
Grey&Black GND
ALARM
NC1
COM1
Green
White
Grey

7. Relay operation (Pulse mode and Toggle mode)
Both of the two relays on board can operate in Pulse Mode
(suitable for access control) or Toggle Mode (suitable for
arming/disarming alarms, switching lights, machines...etc)
Everytime a valid card/ tag read or valid PIN input in Pulse
Mode, the relay will operate, for the pre-set relay pulse time.
Everytime a valid card/ tag read or valid PIN input in Toggle
Mode, the relay changes state, which will not turn back until
read card or input PIN again.
Yellow OPEN1
Brown D_ IN
Red
Black
AC&DC
AC&DC
Blue & Black NO2
Green & Black
2MOC& kcalBetihW
NC2
Blue NO1
2NEPO& kcalBwolleY
Grey&Black GND
ALARM
NC1
COM1
Green
White
Grey
1 2 3 4 5
+MOT- FO +24 FC
6 7 8 9 10 11
+LAMP- +BAT- +SOLAR-
12 13 14 15 16 17 18 19
+24OUT- OSC PHOTO XB1 XB2
LEARN
AC2700, AR2750
AR900
- MOTOR + LL COM RL
- LAMP + PHOTOCELL PUSHBUTTON LOCK LOOP - 24VDC OUT + - BAT +
1 2 6 7
5
3 4 8 9 10 11 12 13 14 15 16 17 18 19
Yellow OPEN1
Brown D_ IN
Red
Black
AC&DC
AC&DC
Blue & Black NO2
Green & Black
2MOC& kcalBetihW
NC2
Blue NO1
2NEPO& kcalBwolleY
Grey&Black GND
ALARM
NC1
COM1
Green
White
Grey
AC1300,AR1350,AC2200,AR2250
Yellow OPEN1
Brown D_ IN
Red
Black
AC&DC
AC&DC
Blue & Black NO2
Green & Black
2MOC& kcalBetihW
NC2
Blue NO1
2NEPO& kcalBwolleY
Grey&Black GND
ALARM
NC1
COM1
Green
White
Grey

10. Sound a nd L i ght i ndic at i on
Operation Status
Zone1 unlock
Zone2 unlock
Power on
Operation successful
Operation failed
Enter into programming mode
Red Light
-
-
Bright
Shines
slowly
-
-
Green Light
Bright
-
-
-
-
-
-
Blue Light
-
Bright
-
-
-
-
Bright
Buzzer
Short Ring
Short Ring
Long Ring
-
Short Ring
Long Ring
Press keypad
-
Bright
-
-
-
-
3 Short Rings
Long Ring
11 et ailed Pr ogramming Gui d e
Stand by
In the programming mode
Exit from the programming mode
Alarm
Bright Bright - -
Shines
slowly
Shines
quickly -
-
-
-Long Ring
Alarm
11.1 User Settings
To exit from the programming mode
To enter the programming mode
Note: All the steps below must be done after entering into the programming mode
Master code
#
888888 is the default factory master code
8. Reset t o Fac t or y Def au l t
9. Ant i Tam per A l ar m
The ses a LDR (light dependent resistor) as
an anti tamper alarm. If the keypad is removed from the
cover then the tamper alarm will operate.
To reset to factory default, power off, press * , hold it and
power on, release it until hear three beeps(two short, one
long), means reset to factory default successfully.
Remarks: Reset to factory default, the user’ s information is
still retained.
LM178
LM178

To add a card user (Method 1)
This is an easy way to enter cards with auto-generated ID
numbers The ID number will start from 1 if no user has
been programmed
1 Read Card #
Cardscan be added continuously without exiting
programming mode
To change the master code
Set valid Card or PIN users
Set valid Card and PIN users
0 New code # New code #
The master code is any 6 digits
Setting t he w orking m ode:
3
Entry is by either card or PIN (Factory default s etting)
1 2 , Zone 1
, Zone 2
2 2
3
#
#
3
Entry is by card and PIN together
1 1 , Zone 1
, Zone 2
2 1
3
#
#
To add a PIN users
To delete a PIN user
To change the PIN of a PIN user (Note: This step must
be done out of programming mode)
2 User ID number #
Users can be deleted continuously without exiting
programming mode
Note:
When adding users, if the card or PIN user has been enrolled already, you can not
add it again on the same zone,
or the device will give a bleep as error. But it is ok to enroll the same card or PIN for the both zones
Factory default s etting: Card or PIN mode
To set user for Zone 1 3 1 2 #( )
1 User ID number # PIN #
The ID number is any number among 1- 1100. The PIN
is any 4- 8 digits between 0000- 9 9999999 with the
exception of 1234 which is reserved. Users can be
added continuously without exiting programming
mode as follows:
1 UserIDNo1 # PIN # UserIDNo2 # PIN #
UserIDnumber# OldPIN# NewPIN# NewPIN#

To delete Card users by user ID
This option can be used when a user has lost their card
To delete Card users by card number Cardscanbedeletedcontinuouslywithoutexiting
from programmingmode
To add Card Users (Method 1) Auto-generated ID numbers
To add a series cards users-Block Enrollment
The card number must be consecutive (This operation is only
for Zone 1)
To delete card users by cards
Note: Users can be deleted continuously without exiting
programming mode
1 User ID number # Card #
The ID number can be any number between 1-1100
To add a card user (Method 2)
This is the alternative way to enter cards using user ID
allocation. In this method a user ID is allocated to a card.
Only one user ID can be allocated to a single card
Card quantity is between 1-1100 Of the 8 digits card number,
it is the last 8 digits onthe card Maximum 1100 cards can be
enrolled at a stretch within 1 minute
5 User ID number # 8 digits Card number # Card quantity #
The device can automatically identify the card of
Zone 1 or Zone 2
2 Read Card #
2 User ID #
To set user for Zone 2 ( )
32 2 #
To set PIN user for Zone 2 is the same as Zone 1, only the ID number is 1101-1200 for Zone 2.
To set Card user for Zone 2 is the same as Zone 1, with the exception of adding Card users with auto-generated ID numbers
(Method 1) as below
Card can be added continuously without
exiting programming mode
5 Read card #
9 Input 8 d igits card number #
Car d a nd PIN M ode
To set user for Zone 1 ( )
31 1 #
To add a card and PIN user
(The PIN is any 4-8 digits between 0000-99999999 with
the exception of 1234 which is reserved)
Add the card as for a card user Press * to exit from the
programming mode Then allocate the card a PIN as
follows: * Read card 1234 # PIN # PIN #

To unlock t he door (or change relay state)
For a PIN user Enter the PIN then press #
For a card User
For a card and PIN user
Note: This is a dangerous option,
so use with care
To set Card user only
Card only Mode(in this mode, users can only be valid by card)
To delete ALL users
To change a PIN in card and PIN mode (Method 1)
Note that this is done outside programming mode so the
user can undertake this themselves
To change a PIN in card and PIN mode (Method 2)
Note that this is done outside programming mode so the
user can undertake this themselves
3 1 0 # , Zone 1
3 2 0 # , Zone 2
Entry is by Card only
Delete all users of Zone 1: 2 0 000 #
Delete all users of Zone 2: 9 0 000 #
weN #NIP#NIPweN#NIPdlOdracdaeR*
weN #NIP#NIPweN#NIPdlO#rebmunDIresU*
2 Read card # or 2 User ID #
To set users for Zone 2 ( 3 2 1 # ) The operation is the same as Zone 1
To delete a Card and PIN user just delete the card
Read card
Read card then enter PIN #
11.2 Relay Setting ( Pu l se m od e, Toggl e m od e)
Pulse m od e (Fact or y d ef au l t )
Pulse mode - Door relay time setting
For Zone 1: 4 1 1-99 #
For Zone 2: 4 2 1-99 #
The door relay time is between 1-99 seconds, the factory
default setting is 5 seconds

For Zone 1: 4 1 0 #
For Zone 2: 4 2 0 #
11.3 Door D et ec t i on , Al arm , Ac ou st i c Si gnal, Door B el l Settings
Toggle mode
Toggle mode
Door Open Detection
Door Open Too Long (DOTL) warning. When used with an optional magnetic contact or built-in magnetic contact
of the lock, if the door is opened normally, but not closed after 1 minute, the inside buzzer will beep automatically
to remind people to close the door and continue for 1 minute before switching off automatically.Door Forced
Open warning. When used with an optional magnetic contact or built-in magnetic contact of the lock, if the door
is forc ed open, or if the door is opened after 120 seconds of the electro- mechanical lock not closed properly, the
inside buzzer and alarm output will both operate. The Alarm Outputtime is adjustable between1-3minutes with
the default being 1minutes.
To disable door open detection ( Factory default setting )
6 0 #
To enable door open detection
For Zone 1: 6 1 #
For Zone 2: 6 2 #
You can enable the door open detection of only one Zone
Keypad lockout & alarm output options
If there are 10 invalid cards or 10 incorrect PIN numbers in a 10 minute period either the keypad will lockout for
10 m inutes or the alarm will operate , depending on the option selected below
Normal status: No keypad lockout or alarm
Keypad Lockout
Alarm output
Keypad Tone
The keypad tone can be set on or off. When on, the device will give the voice when press the keys; when off, the
device will be in silent
Alarm Output time
To set the alarm output time(1~ 3 minutes)Factory
defaul is 1 minute
7 0 # ( Factory default setting)
7 0 #
7 2 # (Alarm output time:1 minute)
8 1 ~ 3 #

Change Zone 2 to Door Bell
When no need to operate a second door, Zone 2 can be set to operate the Door Bell. The wiring is connecting the
door bell to COM2 and NO2. Press #, the keypad will send the signal to the door bell
To remove the alarm
To remove the door forced open warning
Toremove the dooropentoolong warning
Close the door or Read valid card or Master code #
To enable the keypad tone
To disable keypad tone
8 6 # ( Factory default setting)
8 7 #
Zone 2
Doorbell
8 8 # ( F actory default )
8 9 #
Read valid card or Master code #

To delete a PIN or a card user
To Unlock the door for Zone 1 or Zone 2
To exit from the programming mode
To change the master code
* Master code #
888888 is the default factory master code
To enter the programming mode
Note that t o undertake the follow ing programming the master user m ust b e logged in
Quic k R ef erence Pr ogr am m ing Gui d e
The ID number is any number between 1-1100 for
Zone1 and any number between 1101-1200for
Zone 2 Users can be added continuously without exiting
programming mode
For Zone1: 1 User ID Number # P IN #
For Zone2: 1 User ID Number # P IN #
To add a card
To add a PIN user
The PIN is any 4-8 digits between
0000-99999999 with the exception
of 1234 which is reserved
*
The master code is any 6 digits
0 New code # New code #
Cards can be added continuously without exiting
programming mode
For Zone 2: 5 Read Card #
For Zone 1: 1 Read Card #
Users can be deleted continuously without
exiting programming mode
2 User ID number # f or a PIN user
2 Read Card # f or a card user
To Unlock the door for a PIN user
To Unlock the door for a card user
Enter the PIN then press #
Present the card
LM178
Table of contents