- 1 -
User Manual of Electromagnetic Lock
(Model:LM176)
☆Technical Parameters:
A. Holding power: 280KGS、B. Working Voltage: 24VDC
C. Working Current:250mA D. Safety mode: Power-on to lock, Power-off to open.
E. Typical Installation:Flushing(A)、 Hanging(G)
☆Installtion chart
Hanging Type Electromagnetic Lock Electromagnetic Lock fitting for all kinds of doors.
Flush Bonding Type
☆Typical Installation:
STEP 1
A.Fold template along dotted line.
B.Place template against door and head frame.
C.Drill holes as indicated on temple.
STEP 2
A.Mount the armature palte to door using 1 rubber washer sandwiched between 2 steel washer(the rubber washer and 2 steel washer are installed on the
through sexnut between the armature plate and door).
STEP 3
A.Install the mounting plate with 2 flat head screws(the 2 M5X5 flat head screws are installed in the solotted holes for adjustment).
B.Adjust mounting plate so that it forms right angle with the armature plate.
C.Using the mounting plate as a temple,drill the wire hole.
D.Drill and remaining mounting screws.
STEP 4
A.Instal magnet to mounting plate with 2 M4 screws supplied.
STEP 5
A.Test all functions of this model(see wiring instruction).