Alfalaval TE67 Series User manual

2. Product identification
The device can be identified by its manufacturing label. t
provides the most important data. By the ordering code the
product can be clearly identified.
Fig. 1 manufacturing label,example
The manufacturing label must not be removed from the
device.
3. Mechanical Installation
3.1 Mounting and safety instructions
*WARN NG! nstall the device only when depressurized.
*WARN NG! This device may only be installed by qualified
technical personnel who has read and understood the
instruction manual!
Handle this high-sensitive precision measuring device with
care, both in packed and unpacked condition!
There are no modification/changes to be made on the device.
Do not throw the package/device!
To avoid damaging the instrument, remove packaging and
protective cap directly before starting assembly. The delivered
protective cap has to be stored!
Place the protective cap on the pressure post again
immediately after disassembling.
Do not use any force when installing the device to prevent
damage of the device and the plant!
3.2 General installation steps
Carefully remove the pressure measuring device from the
package and dispose of the package properly.
4. Initial start-up
*WARN NG! Before start-up, the user has to check for
proper installation and for any visible defects.
*WARN NG! The device can be started and operated by
authorized personnel only, who have read and understood
the instruction manual.
*WARN NG! The device has to be used within the technical
specifications only! (Compare the data in the data sheet)
5. Placing out of service
*WARN NG! Disassemble the device only in pressure
less condition!
*WARN NG! Depending on the medium, it may cause
danger for the user. Comply therefore with adequate
precautions for purification.
6. Maintenance
n principle, this device is maintenance-free. f desired, the
housing of the device can be cleaned usuíng a damp cloth
and non-aggressive cleaning solutions.
Instruction Manual
Alfa Laval Pressure Gauge
TE67Dxxxxxxxxx
1. General information
1.1 Information on the Instruction manual
This nstruction manual contains important information on
proper usage of the device. Read this instruction manual
carefully before installing and starting up the pressure
measuring device.
Adhere to the safety notes and operating instructions which
are given in the instruction manual. Additionally applicable
regulations regarding occupational safety, accident prevention
as well as national installation standards and engineering
rules must be complied with!
This instruction manual is part of the device, must be kept
nearest its location, always accessible to all employees.
This instruction manual is copyrighted. The contents of this
instruction manual reflect the version available at the time of
printing. t has been issued to our best knowledge. However,
errors may have occurred. Alfa Laval Kolding A/S is not liable
for any incorrect statements and their effects.
- Technical modifications reserved –
1.2 Target group
WARN NG! To avoid operator hazards and damages of the
device, the following instructions have to be worked out by
qualified technical personnel.
1.3 Limitation of liability
By non-observance of the instruction manual, inappropriate
use, modification or damage, no liability is assumed and
warranty claims will be excluded.
1.4 Intended use
The Alva Laval Pressure Gauges TE67Pxxxxxxxxx have,
according to the type, been developed for applications in
overpressure and vacuum measurement. t is the operator’s
responsibility to check and verify the suitability of the device
for the intended application. f any doubts remain, please
contact our local Alfa Laval Company in order to ensure
proper usage. Alfa Laval Kolding A/S is not liable
for any incorrect selections and their effects.
Permissible media are gases or liquids, specified in the data
sheet. n addition it has to be ensured, that this medium is
compatible with the media wetted parts.
- The technical data listed in the current data sheet are
engaging and must be complied with. f the data sheet is not
available, please order or download it from our homepage
(http://www.alfalaval.com)
*WARN NG! Danger through improper usage
1.5 Package contents
Please verify that all listed parts are undamaged included in
the delivery and check for consistency specified in our order:
- pressure gauge
- mounting instructions
Page 1
M-TE91K030-EN4
TE67D
3/8” BSP
Original Manual

Instruction Manual
Alfa Laval Pressure Gauge
TE67Dxxxxxxxxx
7. Service / epair
7.1 eturn
Upon every return of the device, no matter if for recalibration,
decalcification, modifications or repair, it is necessary to
contact your local Alfa Laval office to guarantee a quick
execution of your request.
Please inform us by sending an email to:
nclude the number of devices sent and request a Return
Number. Afterwards clean the device, pack it shatterproof
and send it to Alfa Laval Kolding A/S indicating the Return
Number.
8. Warranty conditions
The warranty conditions are subject to the legal warranty
period of 12 months from the date of delivery. n case of
improper use, modifications of or damages to the device,
we do not accept warranty claims. Damaged diaphragms
will also not be accepted. Furthermore, defects due to
normal wear are not subject to warranty services.
How to contact Alfa Laval Tank Equipment A/S
For further information please feel free to contact:
Alfa Laval Kolding A/S
PO Box 802
6000 Kolding
Denmark
Phone no.: +45 79 322200, Fax no.: +45 79 322580
www.alfalaval.com
© Alfa Laval Corporate AB
This document and its contents is owned by Alfa Laval
Corporate AB and protected by laws governing intellectual
property and thereto related rights. t is the responsibility
of the user of this document to comply with all applicable
intellectual property laws. Without limiting any rights related
to this document, no part of this document may be copied,
reproduced or transmitted in any form or by any means
(electronic, mechanical, photocopying, recording, or other-
wise), or for any purpose, without the expressed permission
of Alfa Laval Corporate AB. Alfa Laval Corporate AB will
enforce its rights related to this document to the fullest extent
of the law, including the seeking of criminal prosecution.
Page 2
M-TE91K030-EN4

Page 3
Case material A S 304
Window PC (unbreakable)
Bezel A S 304
Liquid filling Glycerine
Transmission fluid Silicone oil
Overload pressure 130% of full span
Accuracy Class 1 (at 20°C) acc. to EN 13190: 2001
Thermal drift +- 0,4% per +- 10°C
Approvals Conforms to EN 837-1 and PED 97-23 CE
Specifications
Measuring range (bar/kPa or bar/psi)
-1 to +1,5 bar (-14,5 to +22 psi)
-1 to +3 bar (-14,5 to +45 psi)
0 to +2.5 bar (0 to +40 psi)
0 to +4 bar (0 to +60 psi)
0 to +6 bar (0 to +90 psi)
0 to +10 bar (0 to +150 psi)
0 to +16 bar (0 to +230 psi)
0 to +25 bar (0 to +360 psi)
0 to +40 bar (0 to +600 psi)
0 to +60 bar (0 to +870 psi)
M-TE91K030-EN4
TE67Dx1xxxxx6x Dial 80 mm, Clamp 38
TE67Dx2xxxxx6x Dial 80 mm, Clamp 51

Page 4
M-TE91K030-EN4
TE67Dx1xxxxx4x Dial 100 mm, Clamp 38
TE67Dx2xxxxx4x Dial 100 mm, Clamp 51

Page 5
M-TE91K030-EN4
TE67Dx1xxxxx7x Dial 80 mm, Clamp 38
TE67Dx2xxxxx7x Dial 80 mm, Clamp 51

Page 6
M-TE91K030-EN4
Alfa Laval Kolding A/S
PO Box 802
6000 Kolding
Denmark
www.alfalaval.com
TE67Dxxxxxxx5x Dial 100 mm, Clamp 38
TE67Dx2xxxxx5x Dial 100 mm, Clamp 51

Ordering Key Table Pressure Gauge
Description Option Item Nr. Code
Measuring Range ´-1 to 1,5 bar (-14,5 -21,76 psi) TE67D1xxxxxxxx
0-4 bar (0 - 58 psi) TE67D2xxxxxxxx
0-10 bar (0-145 psi) TE67D3xxxxxxxx
0-16 bar (0-232 psi) TE67D4xxxxxxxx
0-40 bar (0-580 psi) TE67D5xxxxxxxx
0-60 bar (0-870 psi) TE67D6xxxxxxxx
´-1 to 3 bar (-14,5 - 43,5 psi) TE67D7xxxxxxxx
0-2,5 bar (0-36,3 psi) TE67D8xxxxxxxx
0-6 bar (0-87 psi) TE67D9xxxxxxxx
Process Connection
Clamp DN 38 ( SO2852) /
Clamp DN 40 (D N32676) TE67Dx1xxxxxxx
Clamp DN 50 ( SO2852) /
Clamp DN 51 (D N32676) TE67Dx2xxxxxxx
Surface Finish Wetted Parts Ra<0,8µ TE67Dxx3xxxxxx
Ra<0,4µ (Electropolished) TE67Dxx2xxxxxx
Wetted Part Material A S 316L TE67Dxxx1xxxxx
Teflon TE67Dxxx2xxxxx
Power Supply N/A TE67Dxxxx0xxxx
Scale Bar/Kpa TE67Dxxxxx0xxx
Bar/Psi TE67Dxxxxx1xxx
Accuracy K1 TE67Dxxxxxx1xx
Others Dial 80 bottom connection TE67Dxxxxxxx6x
Dial 80 back connection TE67Dxxxxxxx7x
Dial 100 bottom connection TE67Dxxxxxxx4x
Dial 100 back connection TE67Dxxxxxxx5x
Certificates Calibration Certificate TE67Dxxxxxxxx1
3.1 Certificate TE67Dxxxxxxxx2
3.1. Certificate + 3A TE67Dxxxxxxxx3
3A TE67Dxxxxxxxx4
Calibration Certificate + 3A TE67Dxxxxxxxx5
Calibration Certificate +
3.1. Certificate TE67Dxxxxxxxx6
Calibration Certificate +
3.1. Certificate + 3A TE67Dxxxxxxxx7
N/A TE67Dxxxxxxxx0
Page 7
M-TE91K030-EN4



Table of contents
Other Alfalaval Measuring Instrument manuals