Step Connection TestPoint/ P.W.Board
Coordinates Adjustment
5 Figure2
TP8018- TP8019
(4-A) (4-A)
TP8020- TP8021
(4-A) (4-A)
TP8022- TP8023
(4-A) (4-A)
(1) Thepointwith which avalueservesas themaximum in atestpointis investigated.
(TEST POINT 1: TP8018- TP8019, TESTPOINT 2 : TP8020- TP8021,
TEST POINT3 : TP8022- TP8023)
(2)
Thevalueof thepointwith which a valueservesas themaximum in atestpoint
is measured.
(SPEC) TESTPOINT:1.8±1.4mVOK
(SPEC) TEST POINT: others1.8±1.4mVNG
NOTE : NG : ProceedsameAutoAdjustmentofstep(3).
(3) VR100is turnedandthevalueofthetestpointof(2) is adjusted.
(SPEC) TESTPOINT:1.8±1.4mV
7 Figure2
TP8043- TP8042
(2-A) (2-A)
TP8041- TP8040
(2-A) (2-A)
TP8039- TP8038
(2-A) (2-A)
(1) Thepointwith which avalueservesas themaximum in atestpointis investigated.
(TEST POINT 1: TP8043- TP8042, TESTPOINT 2 : TP8041- TP8040,
TEST POINT3 : TP8039- TP8038)
(2)
Thevalueof thepointwith which a valueservesas themaximum in atestpoint
is measured.
(SPEC) TESTPOINT:1.8±1.4mVOK
(SPEC) TESTPOINT:others1.8±1.4mV NG
NOTE : NG : ProceedsameAutoAdjustmentofstep(3).
(3) VR200is turnedandthevalueofthetestpointof(2) is adjusted.
(SPEC) TESTPOINT:1.8±1.4mV
8 Figure2
TP9058- TP9059
(2-G) (2-G)
TP9060- TP9061
(2-G) (2-G)
TP9062- TP9063
(2-G) (2-G)
(1) Thepointwith which avalueservesas themaximum in atestpointis investigated.
(TEST POINT 1: TP9058- TP9059, TESTPOINT 2 : TP9060- TP9061,
TEST POINT3 : TP9062- TP9063)
(2)
Thevalueof thepointwith which a valueservesas themaximum in atestpoint
is measured.
(SPEC) TEST POINT: 1.8±1.4mVOK
(SPEC) TESTPOINT:others1.8±1.4mV NG
NOTE : NG : ProceedsameAutoAdjustmentofstep(3).
(3) VR400is turnedandthevalueofthetestpointof(2) is adjusted.
(SPEC) TEST POINT: 1.8±1.4mV
9 Figure2
TP9035- TP9030
(4-G) (4-G)
TP9031- TP9032
(4-G) (4-G)
TP9033- TP9034
(4-G) (4-G)
(1) Thepointwith which avalueservesas themaximum in atestpointis investigated.
(TEST POINT 1: TP9035- TP9030, TESTPOINT 2 : TP9031- TP9032,
TEST POINT3 : TP9033- TP9034)
(2)
Thevalueof thepointwith which a valueservesas themaximum in atestpoint
is measured.
(SPEC) TEST POINT: 1.8±1.4mV OK
(SPEC) TEST POINT: others1.8±1.4mVNG
NOTE : NG : ProceedsameAutoAdjustmentofstep(3).
VR300is turnedandthevalueofthetestpointof(2) is adjusted.
(SPEC) TEST POINT: 1.8±1.4mV