TECHNICAL INFORMATION
Power to Lock/F il open.
St inless steel bolt - di meter 15mm
- throw 15mm
Volt ge required 12vDC
Activ ting current 1.0A
Holding current 250 mA
Fully protected g inst tr nsients nd
reverse pol rity
The Autolock Time Del y c n be set for
0, 3, 6 or 9 seconds.
Monitoring - Door position switch (DSS)
- Bolt position indic tor
GENERAL INSTALLATION
INSTRUCTIONS
Ensure you h ve the following:-
- Strike pl te
- Electric bolt
All reb te strips nd/or fr me stops
should be fitted before st rting.
A 2 mp Power Supply should be
provided to ensure there is Full 1
mp for the bolt. This should llow for
b sic Access System nd b ck up
b ttery to be connected to the s me
source.
WARNING - THE CONNECTION
OF AN INCORRECT VOLTAGE
MAY RESULT IN DAMAGE NOT
COVERED BY THE PRODUCT
WARRANTY.
The selection of ppropri te power
supply c ble is very import nt to
ensure lock receives sufficient power
to oper te.
First Choice for Locking Solutions
012 0 2676262 01202 680101 alpro@iecltd.co.uk www.alpro.co.uk
T F E W
1
2
4
3
alpro®
Bolt Face Plate 203 x 34 x 3mm
Strike Plate 98 x 34 x 3mm