manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Botex
  6. •
  7. Power Distribution Unit
  8. •
  9. Botex PSA 322-6 DL User manual

Botex PSA 322-6 DL User manual

Other Botex Power Distribution Unit manuals

Botex PSA-631 User manual

Botex

Botex PSA-631 User manual

Botex BO-6-PW User manual

Botex

Botex BO-6-PW User manual

Botex Powerbox BO-6-S2 User manual

Botex

Botex Powerbox BO-6-S2 User manual

Popular Power Distribution Unit manuals by other brands

Lightcorp Nik installation instructions

Lightcorp

Lightcorp Nik installation instructions

hager SP 015 User instructions

hager

hager SP 015 User instructions

Pakedge PowerPak 9 user guide

Pakedge

Pakedge PowerPak 9 user guide

Pts 9042 Series installation guide

Pts

Pts 9042 Series installation guide

Shure WA405 user guide

Shure

Shure WA405 user guide

CORNING CCH 4U quick start guide

CORNING

CORNING CCH 4U quick start guide

Panamax M4LT-EX datasheet

Panamax

Panamax M4LT-EX datasheet

PANCONNECT FLAT 3M Assembly instruction

PANCONNECT

PANCONNECT FLAT 3M Assembly instruction

Raytheon 138-118 manual

Raytheon

Raytheon 138-118 manual

StarTech.com RKPW161915 Spec sheet

StarTech.com

StarTech.com RKPW161915 Spec sheet

D&R ELECTRONICS PDU-6SS user manual

D&R ELECTRONICS

D&R ELECTRONICS PDU-6SS user manual

GE QuiXtra 4000 Assembly and mounting instructions

GE

GE QuiXtra 4000 Assembly and mounting instructions

Vertiv Knürr DI-Strip Rack PDU manual

Vertiv

Vertiv Knürr DI-Strip Rack PDU manual

ABB PSBS0065 Instruction handbook

ABB

ABB PSBS0065 Instruction handbook

Baumuller BFN 3-1-0007-001 Instruction handbook

Baumuller

Baumuller BFN 3-1-0007-001 Instruction handbook

Eaton StructuredWiringSolutions ESWT41600 Instruction leaflet

Eaton

Eaton StructuredWiringSolutions ESWT41600 Instruction leaflet

GE GEK-45404F instructions

GE

GE GEK-45404F instructions

Huawei PDU8000 Series user manual

Huawei

Huawei PDU8000 Series user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Thomann GmbH • Hans-Thomann-Straße 1 • 96138 Burgebrach • www.thomann.de • [email protected] DocID: 479127_25.01.2022
PSA 322-6 DL
Safety instructions
Intended use
This device is used to distribute mains voltage to several consumers. Any other use
or use under other operating conditions is considered to be improper and may result
in personal injury or property damage. No liability will be assumed for damages re-
sulting from improper use.
Danger for children
Ensure that plastic bags, packaging, etc. are disposed of properly and are
not within reach of babies and young children. Choking hazard! Ensure
that children do not detach any small parts from the product. They could
swallow the pieces and choke! Never let children unattended use electri-
cal devices.
Electric shock caused by high voltages inside
Within the device there are areas where high voltages may be present. Never remove
any covers. There are no user-serviceable parts inside.
Handling the supply cord
Do not place the device or speaker boxes or similar on the supply cord and be careful
not to pinch it. Never tie a knot in the supply cord or tie it with other cables. Route
the supply cord so that no one steps on or trips over it. A damaged supply cord can
cause a re or electric shock. Replace any broken cables.
Quick Start Guide
This quick start guide contains important information on the safe operation of the
product. Read and follow the safety advice and instructions given. Retain the quick
start guide for future reference. If you pass the product on to others please include
this quick start guide.
Where to use the product
Never use the product
• in direct sunlight
• in conditions of extreme temperature or humidity
• in extremely dusty or dirty areas
• at locations where the unit can become wet
• near magnetic elds
General handling
• To prevent damage, never use force when handling the product.
• Never immerse the product in water. Just wipe it with a clean dry cloth. Do not use
liquid cleaners such as benzene, thinners or ammable cleaning agents.
Keep foreign substances from the unit!
Keep the device away from containers with liquids. Should any liquid get into the
unit, this could lead to its destruction, re or electric shock. Be sure not to let any
metal objects into the unit.
EN
Features
• Power distributor 32A with digital measuring instrument
• For indoor use
• Clear allocation of fuses and outputs using letters
• LED display for voltage present per phase
• 19" housing for rack mounting (3 RU)
Connections and operating elements
ö
#
' (
$
&%
öPhase lights
#Digital measuring instrument (display) with function buttons
SET
Opens the main menu, conrms the set value
Decreases the displayed value
Increases the displayed value
Returns to the previous menu item
$Fuses
%Safety socket (2 per phase)
&32A/400V appliance outlet
'Lockable output sockets (Power Twist, 2 per phase)
(CEE32A/400V plug with cable (H07RN-F 5G6mm²)
Thomann GmbH • Hans-Thomann-Straße 1 • 96138 Burgebrach • www.thomann.de • [email protected] DocID: 479127_25.01.2022
PSA 322-6 DL
EN
For the transport and protective packaging, environmentally friendly
materials have been chosen that can be supplied to normal recycling.
Ensure that plastic bags, packaging, etc. are properly disposed of. Do
not just dispose of these materials with your normal household waste,
but make sure that they are collected for recycling. Please follow the
notes and markings on the packaging.
This product is subject to the European Waste Electrical and Electronic
Equipment Directive (WEEE) in its currently valid version. Do not dis-
pose of your old device with your normal household waste. Dispose of
this product through an approved waste disposal rm or through your
local waste facility. Comply with the rules and regulations that apply in
your country. If in doubt, consult your local waste disposal facility.
Technical specications
• Rear outputs 6×safety socket (2 per phase)
6×Power Twist (2 per phase)
1×32A/400V appliance outlet
• Rear input CEE32A/400V plug
with cable (H07RN-F 5G6mm²)
• Front panel 3×phase light
1×digital measuring instrument
• Fuses 6×RCBO C16
• Residual current switch-off 30 mA
• Residual current type A
• Supply voltage 400V~50Hz, 32A per phase
• Housing material Metal
• Degree of protection IP20
• Installation height 3RU
• Dimensions (W×H×D) 482mm×133mm×227mm
• Weight 2.85kg
• Ambient conditions Temperature range 0°C...40°C
Relative humidity 20%...80%
(non-condensing)
Operating
1. Press and hold
SET
until the display shows "Code".
2. Press and enter the password "0001" ein.
3. Press again
SET
to open up the main menu.
4. Select "DISP" and conrm the selection with
SET
.
5. Press and choose between the following modes:
"U": Input voltage
"I": Current intensity
"P": Active power
"Q": Net frequency
"S": Apparent power
"PF": Reactive power
6. Conrm the selection with
SET
.
-> the display shows the selected mode.
The display shows "U1, 2, 3": 3-phase input voltage,
1=L1, 2=L2, 3=L3,
"V" is the input voltage,
"F" is the input frequency.
The display shows "I1, 2, 3": 3-phase current intensity,
1=L1, 2=L2, 3=L3,
"A" is the input current,
"Σ" is the total current.
The display shows "P1, 2, 3": 3-phase active power,
1=L1, 2=L2, 3=L3,
"W" is the active power,
"Σ" is the total active power.
The display shows "Q1, 2, 3": 3-phase net frequency,
1=L1, 2=L2, 3=L3
The display shows "S1, 2, 3": 3-phase apparent power,
1=L1, 2=L2, 3=L3,
"VA" is the apparent power,
"Σ" is the total apparent power.
The display shows "PF1, 2, 3": 3-phase reactive power,
1=L1, 2=L2, 3=L3,
"VA" is the reactive power,
"Σ" is an average value.
7. Press to switch between the modes.
8. For switching automatically every four seconds between the modes,
open up the main menu and select "CYC".
Conrm the selection with
SET
.
9. For deleting the measuring memory, open up the main menu and
select "Cle.E".
Conrm the selection with
SET
.
10. To return to the previous menu item, press .