- 2 - Trove Software House XBV PTC Kits Installation Guide
Overview:
Altronix Trove Software House kits are pre-assembled and consist of Trove enclosure with factory installed Altronix power supply/chargers and
sub-assemblies. These kits also accommodate various combinations of Software House boards for up to sixteen (16) doors in a single enclosure.
Configuration Chart:
Altronix
Model
Number
220VAC
60Hz
Input
Current
(A)
Power
Supply
Board
Input
Fuse
Rating
Power
Supply
Board
Battery
Fuse
Rating
Nominal DC Output
Voltage Options
Maximum
Supply Current
for Main Output
on Power Supply
board and
ACM8CB
Access Power
Controller’s
outputs (A)
Fail-
Safe/
Fail-
Secure
Outputs
Current Per
ACM8CB Output (A)
ACM8CB Board
Input Fuse Rating
ACM8CB Board
Output PTC Rating
PDS8CB Board
Input PTC Rating
PDS8CB Board
Output PTC Rating
PD8ULCB Board
Output PTC Rating
Power
Supply 1
Power
Supply 2
24VDC
Output
Range
(V)
12VDC
Output
Range
(V)
T2SK78DV 2.5 5A/
250V
15A/
32V 20.17-26.4 – 24VDC @ 9.2A 8 2.0 10A/
250V 2.5A 9A 2.5A –
T3SK758DV 3.8 5A/
250V
15A/
32V 20.19-26.4 10.0-13.2 24VDC @ 9.2A 8 2.0 10A/
250V 2.5A – – 2.5A
T3SK7516DV 3.8 5A/
250V
15A/
32V 20.19-26.4 10.0-13.2 24VDC @ 9.2A 16 2.0 10A/
250V 2.5A – – 2.5A
Hardware and Accessories:
• Tamper switch (Altronix Model TS112 or equivalent) - one (1) for T2SK78D, two (2) for T3SK758D or T3SK7516D.
• Cam lock.
• Battery leads.
Installation Instructions:
Wiring methods shall be in accordance with the National Electrical Code/NFPA 70/ANSI, and with all local codes and authorities having jurisdiction.
Product is intended for indoor use only.
1.Remove backplane from enclosure. Do not discard hardware.
2.Mark and predrill holes in the wall to line up with the top three keyholes in the enclosure. Install three upper fasteners and screws
in the wall with the screw heads protruding. Place the enclosure’s upper keyholes over the three upper screws, level and secure.
Mark the position of the lower three holes. Remove the enclosure. Drill the lower holes and install
the three fasteners. Place the enclosure’s upper keyholes over the three upper screws.
Install the three lower screws and make sure to tighten all screws.
3.Mount included UL Listed tamper switch (Altronix Model TS112 or equivalent) in desired location,
opposite hinge. Slide the tamper switch bracket onto the edge of the enclosure approximately 2”
from the right side (Fig. 1, pg. 2). Connect tamper switch wiring to the Access Control Panel input or
the appropriate UL Listed reporting device. To activate alarm signal open the door of the enclosure.
4.Mount Software House boards to backplane, refer to pages 3-5.
5.Refer to the XBV Power Supply/Charger Installation Guide for AL1012XB220 and AL1024XB2V
and corresponding Sub-Assembly Installation Guides for the following models: PD8ULCB, ACM8CB,
PDS8CB, VR6 for further installation instructions.
Metal or Nylon Spacer | 5/16” Pan Head Screw | Lock Nut
Fig. 1
Tamper Switch
(included)
To Access Control Panel or
UL Listed Reporting Device
Edge of
Enclosure
Enclosure