manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Altronix
  6. •
  7. Power Supply
  8. •
  9. Altronix ALTV615DC1016 Series User manual

Altronix ALTV615DC1016 Series User manual

Rev. 102804 More than just power.TM
Installing Company: _______________ Service Rep. Name: __________________________________
Address: _____________________________________________ Phone #: __________________
Installation Guide
ALTV615DC1016 Series
CCTV Power Supplies
Models Include:
ALTV615DC1016
- 6-15VDC @ 10A
- Sixteen (16) Fuse Protected Outputs.
ALTV615DC1016CB
- 6-15VDC @ 10A
- Sixteen (16) PTC Protected Outputs.
For models with the line cord installed add suffix “3”, e.g. ALTV615DC10163
- 2 - ALTV615DC1016 Series Installation Guide
Overview:
ALTV615DC1016 Series DC CCTV Power Supplies provide 6-15VDC distributed via sixteen (16) fuse or PTC
protected outputs for powering CCTV cameras, heaters, and other video accessories.
Sixteen (16) Output ALTV615DC1016 Reference Chart:
Altronix
Model Number
Total
Output
Current
(Power)
Output
Voltage
Number
of
Outputs
PTC
Protected
Outputs
(auto-
resettable)
Fuse
Protected
Outputs
Output
Current
(max. per
output)
115VAC
50/60Hz
Input
Current
ALTV615DC1016 10A 6-15VDC 16 – P3.5A 1.9A
ALTV615DC1016CB 10A 6-15VDC 16 P– 2.5A 1.9A
Specifications:
Input:
• Input 115VAC, 50/60 Hz, 1.9A.
Output:
• Sixteen (16) fuse or PTC protected outputs.
• 6VDC to 15VDC field adjustable.
• 10A total continuous supply current.
• Filtered and electronically regulated outputs.
Features:
• AC input and DC output LED indicators.
• Illuminated power disconnect circuit breaker
with manual reset.
• Unit maintains camera synchronization.
• Ease of installation saves time and eliminates
costly labor.
Enclosure Dimensions (H x W x D approx.):
13.5” x 13” x 3.25”
(342.9mm x 330.2mm x 82.6mm)
Installation Instructions:
1. Mount unit in the desired location. Mark and predrill holes in the wall to line up with the top two keyholes
in the enclosure. Install two upper fasteners and screws in the wall with the screw heads protruding. Place
the enclosure’s upper keyholes over the two upper screws; level and secure. Mark the position of the lower
two holes. Remove the enclosure. Drill the lower holes and install the two fasteners. Place the enclosure’s
upper keyholes over the two upper screws. Install the two lower screws and make sure to tighten all screws
(Enclosure Dimensions, pg. 4). Secure enclosure to earth ground.
2. Connect AC power to the two black and two white flying leads of the transformer (Fig. 1, pg. 3).
Units with line cord installed skip Step #2.
3. Plug the line cord into a grounded AC receptacle (Fig. 1b, pg. 3).
4. Adjust output voltage (unit is factory set at 12VDC): use the trimpot on the power supply board
prior to connecting CCTV devices (Fig. 1a, pg. 3).
5. Measure output voltage before connecting devices. This helps avoiding potential damage.
Terminals marked [1P - 16P] are positive (+) and terminals marked [1N - 16N] are negative (–).
CAUTION: Determine the maximum operating voltage of the equipment being powered before
adjusting the output voltage.
6. Connect devices to terminals marked [1P - 1N] through [16P - 16N] on PD16W/PD16WCB board
(Fig. 1, pg. 3),carefully observing correct polarity.
7. Green LED will illuminate when unit is powered.
8. Upon completion of the wiring, secure enclosure door with screws (supplied).
Caution: Equipment must be installed/serviced by authorized/trained personnel only.
Shut branch circuit power before installing/servicing equipment.
WARNING: To reduce the risk of fire or electric shock, do not expose the unit to rain or
moisture. This installation should be made by qualified service personnel and should
conform to the National Electrical Code and all local codes.
ALTV615DC1016 Series Installation Guide - 3 -
Terminal Identification:
Power Supply Board
Terminal Legend Function/Description
AC / AC Low volage AC input.
+ DC –6VDC-15VDC output.
PD16W - Distribution Module
Terminal Legend Function/Description
1P - 16P Positive DC output.
1N - 16N Negative DC output.
Door
CAUTION: De-energize unit prior to servicing. For continued protection against fire hazard
replace fuse with the same type and rating 3.5A, 250V. Do not expose unit to rain or moisture.
3.5A 250V
For continuous protection against
risk of fire replace fuses with
same type and rating.
common
outputs
protected
outputs
P
N
NPS
XFMR Input
PD16W
12345678
9 10 11 12 13 14 15 16
NP
Wire Strap
(from
Enclosure
to Door)
non-
power
limited
XFMR XFMR
Black Lead
White Lead
For models with
factory installed
3-wire line cord
115VAC input
50/60 Hz
Power Supply
Board
Used on PTC Models
(example:
ALTV615DC1016CB)
P
N
PTCs
NPS
XFMR Input
PD16W
common
outputs
protected
outputs
12345678
9 10 11 12 13 14 15 16
PN
DC outputs
DC outputs
Green
Lead
(ground)
Power Switch
Trimpot
Fig. 1
Fig. 1a
Fig. 1b
- 4 - ALTV615DC1016 Series Installation Guide
1.40”
(35.6mm)
1.40”
(35.6mm)
1.40”
(35.6mm)
4.85” (123.2mm) 4.85” (123.2mm)
3.25” (82.6mm)
0.75”
(19.1mm)
0.75”
(19.1mm)
11.0” (279.4mm)
12.5” (317.5mm)
1.20”
(30.5mm)
1.20”
(30.5mm)
0.9375” (23.8mm)
0.9375” (23.8mm)
5.10” (129.5mm)
1.40”
(35.6mm)
5.10” (129.5mm)
6.5625” (166.7mm)
3.25” (82.6mm)3.25” (82.6mm)
3.25” (82.6mm)
10.5” (266.7mm)
1.0”
(25.4mm)
1.0”
(25.4mm)
1.0” (25.4mm)
13.0” (330.2mm)
5.10” (129.5mm)
1.20”
(30.5mm)
Enclosure Dimensions (H x W x D approximate):
13.5” x 13” x 3.25” (342.9mm x 330.2mm x 82.6mm)
The lightning flash with arrowhead symbol within an equilateral triangle is intended to alert the user
to the presence of an insulated DANGEROUS VOLTAGE within the product’s enclosure that may be of
sufficient magnitude to constitute an electric shock.
The exclamation point within an equilateral triangle is intended to alert the user to the presence of impor-
tant operating and maintenance (servicing) instructions in the literature accompanying the appliance.
CAUTION: To reduce the risk of electric shock do not open enclosure.
There are no user serviceable parts inside.
Refer servicing to qualified service personnel.
Altronix is not responsible for any typographical errors.
––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––
140 58th Street, Brooklyn, New York 11220 USA | phone: 718-567-8181 | fax: 718-567-9056
website: www.altronix.com | e-mail: [email protected] | Lifetime Warranty
IIALTV615DC1016 Series L07U MEMBER

This manual suits for next models

2

Other Altronix Power Supply manuals

Altronix TROVE TC1 User manual

Altronix

Altronix TROVE TC1 User manual

Altronix R2432UL Series User manual

Altronix

Altronix R2432UL Series User manual

Altronix ALTV2432 Series User manual

Altronix

Altronix ALTV2432 Series User manual

Altronix ALTV248UL Operating and maintenance instructions

Altronix

Altronix ALTV248UL Operating and maintenance instructions

Altronix AL400ULX User manual

Altronix

Altronix AL400ULX User manual

Altronix AL600M220 User manual

Altronix

Altronix AL600M220 User manual

Altronix AL600ULX Series User manual

Altronix

Altronix AL600ULX Series User manual

Altronix OLS250 User manual

Altronix

Altronix OLS250 User manual

Altronix SMP7PM User manual

Altronix

Altronix SMP7PM User manual

Altronix ALTV615DC8ULCB User manual

Altronix

Altronix ALTV615DC8ULCB User manual

Altronix AL600ULX Series User manual

Altronix

Altronix AL600ULX Series User manual

Altronix ALTV248220 Series User manual

Altronix

Altronix ALTV248220 Series User manual

Altronix TROVE T1SAK34D User manual

Altronix

Altronix TROVE T1SAK34D User manual

Altronix AL176220 Series User manual

Altronix

Altronix AL176220 Series User manual

Altronix AL1012X220 Series User manual

Altronix

Altronix AL1012X220 Series User manual

Altronix AL300ULXD User manual

Altronix

Altronix AL300ULXD User manual

Altronix TROVE T1RM3F4D User manual

Altronix

Altronix TROVE T1RM3F4D User manual

Altronix TROVE Trove1SP1 User manual

Altronix

Altronix TROVE Trove1SP1 User manual

Altronix SMP10WP12 User manual

Altronix

Altronix SMP10WP12 User manual

Altronix R2416UL User manual

Altronix

Altronix R2416UL User manual

Altronix SMP1012X Series User manual

Altronix

Altronix SMP1012X Series User manual

Altronix AL1024NK8 Series User manual

Altronix

Altronix AL1024NK8 Series User manual

Altronix AL300ULXJG User manual

Altronix

Altronix AL300ULXJG User manual

Altronix OLS20E User manual

Altronix

Altronix OLS20E User manual

Popular Power Supply manuals by other brands

PCB Piezotronics 441A101 Installation and operating manual

PCB Piezotronics

PCB Piezotronics 441A101 Installation and operating manual

Toa VX-2000DS ER instruction manual

Toa

Toa VX-2000DS ER instruction manual

Vimar by-me 01801 instruction sheet

Vimar

Vimar by-me 01801 instruction sheet

Magtrol DES 410 user manual

Magtrol

Magtrol DES 410 user manual

ART DESIGN Mean Well NPF-120-12 user manual

ART DESIGN

ART DESIGN Mean Well NPF-120-12 user manual

Antec PowerUp 6000 user manual

Antec

Antec PowerUp 6000 user manual

M-system Current Loop Supply M3LDY installation manual

M-system

M-system Current Loop Supply M3LDY installation manual

Mission 529i quick start guide

Mission

Mission 529i quick start guide

Satel APS-612 manual

Satel

Satel APS-612 manual

ZALMAN LEII Series user manual

ZALMAN

ZALMAN LEII Series user manual

Vertiv NetSure 802 System application guide

Vertiv

Vertiv NetSure 802 System application guide

Pulsar PSDC 04122 manual

Pulsar

Pulsar PSDC 04122 manual

Energizer ER-PRO1400 quick guide

Energizer

Energizer ER-PRO1400 quick guide

Hotline 85892F manual

Hotline

Hotline 85892F manual

SECO-LARM SLI Enforcer EAP-1D1Q manual

SECO-LARM

SECO-LARM SLI Enforcer EAP-1D1Q manual

Tescom T-100 Series user manual

Tescom

Tescom T-100 Series user manual

Matsusada KAS Series instruction manual

Matsusada

Matsusada KAS Series instruction manual

Chargery S1500 manual

Chargery

Chargery S1500 manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.