manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Altronix
  6. •
  7. Power Supply
  8. •
  9. Altronix ALTV615DCUL Series User manual

Altronix ALTV615DCUL Series User manual

ALTV615DC416UL
- 6-15VDC @ 4A
- Sixteen (16) fuse protected outputs
ALTV615DC616UL
- 6-15VDC @ 6A
- Sixteen (16) fuse protected outputs
ALTV615DC416ULCB
- 6-15VDC @ 4A
- Sixteen (16) PTC protected outputs
ALTV615DC616ULCB
- 6-15VDC @ 6A
- Sixteen (16) PTC protected outputs
ALTV615DCUL Series
CCTV Power Supplies
Models Include:
Rev. 050404 More than just power.TM
Installing Company: _______________ Service Rep. Name: __________________________________
Address: _____________________________________________ Phone #: __________________
Installation Guide
For models with the factory installed 3-wire line cord
add suffix “3”, e.g. ALTV615DC616UL3
- 2 - ALTV615DCUL Series Installation Guide
CAUTION: This installation should be made by qualified service personnel and should conform
to the National Electrical Code and all local codes.
Installation Instructions:
1. Mount unit in the desired location.
2. Connect AC power to the two black and two white flying leads of the transformer (Fig. 1, pg. 3).
Units with line cord installed skip Step 2.
Use 18 AWG or larger for all power connections. Connect green ground lead to earth ground (Fig. 1, pg. 3).
Keep power-limited wiring separate from non power-limited wiring.
Minimum 0.25” spacing must be provided. Use separate knockouts.
3. Adjust output voltage (unit is factory set at 12VDC): use the trimpot on the power supply board
prior to connecting CCTV devices (Fig. 1a, pg. 3).
4. Measure output voltage before connecting devices. This helps avoiding potential damage.
CAUTION: Determine the maximum operating voltage of the equipment being powered before adjusting
the output voltage.
5. Connect devices to the terminals marked [1P - 1N] through [16P - 16N] on PD16W/PD16WCB board,
carefully observing correct polarity (Fig. 1, pg. 3).
Terminals marked [1P - 16P] are positive (+) and terminals marked [1N - 16N] are negative (–).
6. Green LED will illuminate when unit is powered.
7. Upon completion of wiring secure enclosure door with screws (supplied).
WARNING: To reduce the risk of fire or electric shock, do not expose the unit to rain or moisture.
Agency Listings:
• UL Listed for Commercial CCTV Equipment
(UL 2044).
CUL Listed - CSA Standard C22.2 No.1-98,
Audio, Video and Similar Equipment.
Input:
• Input 115VAC, 50/60Hz.
Output:
• Sixteen (16) individual outputs.
• 6VDC to 15VDC field adjustable.
• Outputs are rated @ 3.5A (fused) or 2.5A (PTC).
• Filtered and electronically regulated outputs.
Features:
• AC input and DC output LED indicators.
• Power ON/OFF switch.
• Unit maintains camera synchronization.
• Ease of installation saves time and eliminates
costly labor.
Enclosure Dimensions (H x W x D approx.):
13.5” x 13” x 3.25”
(342.9mm x 330.2mm x 82.6mm).
Overview:
ALTV615DCUL Series DC CCTV Power Supplies provide 6 - 15VDC distributed via fuse or PTC protected outputs
for powering CCTV cameras, heaters, and other video accessories.
ALTV615DCUL Series Reference Chart:
Altronix
Model Number
115VAC 50/60Hz
Input Current
Output Voltage
Total Output
Current (Power)
Number of
Outputs
Output Current
(max per output)
Fuse Protected
Outputs
PTC Protected
Outputs
(auto-resettable)
Class 2 Rated
Power-Limited
ALTV615DC416UL 0.9A 6 - 15VDC 4A 16 3.5A P–P
ALTV615DC416ULCB 0.9A 6 - 15VDC 4A 16 2.5A – P P
ALTV615DC616UL 1.5A 6 - 15VDC 6A 16 3.5A P– –
ALTV615DC616ULCB 1.5A 6 - 15VDC 6A 16 2.5A – P P
Specifications:
ALTV615DCUL Series Installation Guide - 3 -
Terminal Identification:
Power Supply Board
Terminal Legend Function/Description
AC/AC Low voltage AC input.
+ DC – 6VDC -15VDC output.
PD16W/PD16WCB - Distribution Module
1P - 16P Positive DC outputs.
1N - 16N Negative DC outputs.
Door
CAUTION: De-energize unit prior to servicing. For continued protection against fire hazard
replace fuse with the same type and rating: 3.5A, 250V. Do not expose unit to rain or moisture.
3.5A 250V
For continuous protection against
risk of fire replace fuses with
same type and rating.
common
outputs
protected
outputs
P
N
NPS
XFMR Input
PD16W
12345678
9 10 11 12 13 14 15 16
NP
Wire Strap
(from
Enclosure
to Door)
non
power-
limited
XFMR XFMR
Black Lead
White Lead
Input
115VAC
50/60Hz
Power Supply
Board
Trimpot
P
N
PTCs
NPS
XFMR Input
PD16WCB
common
outputs
protected
outputs
12345678
9 10 11 12 13 14 15 16
PN
DC outputs
Green
Lead
(ground)
Power Switch
Used on PTC Models
(example: ALTV615DC416ULCB)
Power-Limited
Class 2
DC outputs
Fig. 1
Fig. 1a
- 4 - ALTV615DCUL Series Installation Guide
Enclosure Dimensions (H x W x D approximate):
13.5” x 13” x 3.25” (342.9mm x 330.2mm x 82.6mm)
The lightning flash with arrowhead symbol within an equilateral triangle is intended to alert the user
to the presence of an insulated DANGEROUS VOLTAGE within the product’s enclosure that may be of
sufficient magnitude to constitute an electric shock.
The exclamation point within an equilateral triangle is intended to alert the user to the presence of impor-
tant operating and maintenance (servicing) instructions in the literature accompanying the appliance.
CAUTION: To reduce the risk of electric shock do not open enclosure.
There are no user serviceable parts inside.
Refer servicing to qualified service personnel.
1.40”
(35.6mm)
1.40”
(35.6mm)
1.40”
(35.6mm)
4.85” (123.2mm) 4.85” (123.2mm)
3.25” (82.6mm)
0.75”
(19.1mm)
0.75”
(19.1mm)
11.0” (279.4mm)
12.5” (317.5mm)
1.20”
(30.5mm)
1.20”
(30.5mm)
0.9375” (23.8mm)
0.9375” (23.8mm)
5.10” (129.5mm)
1.40”
(35.6mm)
5.10” (129.5mm)
6.5625” (166.7mm)
3.25” (82.6mm)3.25” (82.6mm)
3.25” (82.6mm)
10.5” (266.7mm)
1.0”
(25.4mm)
1.0”
(25.4mm)
1.0” (25.4mm)
13.0” (330.2mm)
5.10” (129.5mm)
1.20”
(30.5mm)
Altronix is not responsible for any typographical errors.
––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––
140 58th Street, Brooklyn, New York 11220 USA | phone: 718-567-8181 | fax: 718-567-9056
website: www.altronix.com | e-mail: [email protected] | Lifetime Warranty
IIALTV615DCULSeries K16U MEMBER

This manual suits for next models

4

Other Altronix Power Supply manuals

Altronix AL600ULADA User manual

Altronix

Altronix AL600ULADA User manual

Altronix SMP1012X Series User manual

Altronix

Altronix SMP1012X Series User manual

Altronix Trove1V1 User manual

Altronix

Altronix Trove1V1 User manual

Altronix AL400UL3 User manual

Altronix

Altronix AL400UL3 User manual

Altronix AL624ET User manual

Altronix

Altronix AL624ET User manual

Altronix eFlow6NV User manual

Altronix

Altronix eFlow6NV User manual

Altronix eFLOW EF102NBV-32715 User manual

Altronix

Altronix eFLOW EF102NBV-32715 User manual

Altronix WayPoint DC Series User manual

Altronix

Altronix WayPoint DC Series User manual

Altronix OLS20 User manual

Altronix

Altronix OLS20 User manual

Altronix SMP5 User manual

Altronix

Altronix SMP5 User manual

Altronix AL300ULXD User manual

Altronix

Altronix AL300ULXD User manual

Altronix AL125220 User manual

Altronix

Altronix AL125220 User manual

Altronix LTV615DC48M220 User manual

Altronix

Altronix LTV615DC48M220 User manual

Altronix AL400ULPD8CB User manual

Altronix

Altronix AL400ULPD8CB User manual

Altronix SMP7 User manual

Altronix

Altronix SMP7 User manual

Altronix AL100UL User manual

Altronix

Altronix AL100UL User manual

Altronix R248ULi User manual

Altronix

Altronix R248ULi User manual

Altronix SMP5PM User manual

Altronix

Altronix SMP5PM User manual

Altronix AL300ULXB2 User manual

Altronix

Altronix AL300ULXB2 User manual

Altronix AL125UL User manual

Altronix

Altronix AL125UL User manual

Altronix SMP3CTX User manual

Altronix

Altronix SMP3CTX User manual

Altronix AL1024X220 Series User manual

Altronix

Altronix AL1024X220 Series User manual

Altronix SMP5E Service manual

Altronix

Altronix SMP5E Service manual

Altronix ALTV244 Operating and maintenance instructions

Altronix

Altronix ALTV244 Operating and maintenance instructions

Popular Power Supply manuals by other brands

Aktakom APS-3103 user manual

Aktakom

Aktakom APS-3103 user manual

Moxa Technologies DR-120 Series Hardware installation guide

Moxa Technologies

Moxa Technologies DR-120 Series Hardware installation guide

Gallagher M150 instructions

Gallagher

Gallagher M150 instructions

Pulsar RUPS812T manual

Pulsar

Pulsar RUPS812T manual

LC-POWER PLATINUM Series manual

LC-POWER

LC-POWER PLATINUM Series manual

Panther 107758 user manual

Panther

Panther 107758 user manual

EnerSys alpha Cordex CXRF 48-3.6kW Technical guide

EnerSys

EnerSys alpha Cordex CXRF 48-3.6kW Technical guide

Nemtek MERLIN 4 Installer manual

Nemtek

Nemtek MERLIN 4 Installer manual

Rolls RPB486 Specifications

Rolls

Rolls RPB486 Specifications

BEKA BA212 instructions

BEKA

BEKA BA212 instructions

Xantrex XTR 33-25 operating manual

Xantrex

Xantrex XTR 33-25 operating manual

Alpha BROADBAND UPS XM3.1-HP quick start guide

Alpha

Alpha BROADBAND UPS XM3.1-HP quick start guide

Bogen SPS2410 Installation

Bogen

Bogen SPS2410 Installation

CAMPAGNOLA Li-Ion 700 Use and maintenance manual

CAMPAGNOLA

CAMPAGNOLA Li-Ion 700 Use and maintenance manual

Honeywell Fire-Lite FL-PS6 instruction manual

Honeywell

Honeywell Fire-Lite FL-PS6 instruction manual

Effectrode Atomic owner's manual

Effectrode

Effectrode Atomic owner's manual

ITS Telecom EKSELANS AM 361 EASY MAGNEK quick start guide

ITS Telecom

ITS Telecom EKSELANS AM 361 EASY MAGNEK quick start guide

Extreme Networks RPS installation guide

Extreme Networks

Extreme Networks RPS installation guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.