Overview:
OLS120D2 power supply/charger converts a 115VAC, 50/60Hz or 230VAC, 50/60Hz input to a 12VDC/24VDC output
and a 12VDC fixed output (see specifications). This unit has a wide range of applications for access control and security
system accessories that require additional power.
Specifications:
Installation Instructions:
The OLS120D2 should be installed in accordance with The National Electrical Code and all applicable Local Regulations.
1. Mount the OLS120D2 in the desired location/enclosure.
2. Slide [Power ON/OFF] switch to the OFF position (Fig. 1c, pg. 2).
3. Set the DC1 output voltage via clip switch - open for 24VDC operation or closed for 12VDC operation (Fig. 1a and
1b, pg. 2). DC2 output voltage is fixed at 12VDC operation.
CAUTION: Do not touch exposed metal parts. Shut branch circuit power before installing or servicing equipment.
There are no user serviceable parts inside. Refer installation and servicing to qualified service personnel.
4. Connect AC power to the terminals marked [L & N], connect ground to the terminal marked [G].
Use 18 AWG or larger for all power connections (Battery, DC output).
Use 22 AWG to 18 AWG for power-limited circuits (AC Fail/Low Battery reporting).
5. Slide [Power ON/OFF] switch to the ON position (Fig. 1c, pg. 2).
6. Measure output voltage across both out terminals marked [-- DC1 +, -- DC2 +]before connecting devices.
This helps avoiding potential damage.
7. Slide [Power ON/OFF] switch to the OFF position (Fig. 1c, pg. 2).
8. Connect 12VDC or 24VDC (depending on clip switch setting) device to be powered to the terminals
marked [-- DC1 +].
Connect 12VDC device to be powered to the terminals marked [-- DC2 +] (Fig. 1, pg. 2).
9. When use of stand-by batteries is desired, they must be lead acid or gel type.
Connect battery/batteries to the terminals marked [-- BAT + ] (Fig. 1, pg. 2).
12VDC operation only: Use one (1) 12VDC battery for 12VDC backup.
24VDC and 12VDC simultaneous operation: Use two (2) 12VDC batteries connected in series for 24VDC backup.
10. When batteries are not used, a loss of AC will result in the loss of output voltage.
11. Connect appropriate signaling notification devices to AC Fail & Low battery supervisory
relay outputs marked [NC, C, NO].
12. Slide [Power ON/OFF] switch to the ON position (Fig. 1c, pg. 2).
Maintenance:
Unit should be tested at least once a year for the proper operation as follows:
Output Voltage Test: Under normal load conditions, the DC output voltage should be checked for proper voltage level.
Battery Test: Under normal load conditions check that the battery is fully charged, check specified voltage
(12VDC @ 13.7 or 24VDC @ 27.4) both at the battery terminal and at the board terminals marked [-- BAT + ] to ensure
that there is no break in the battery connection wires.
Note: Maximum charging current under discharges is 0.7 amp.
Note: Expected battery life is 5 years; however, it is recommended changing batteries in 4 years or less if needed.
OLS120D2 - Offline Power Supply/Charger
Input:
• Universalinput115VAC,50/60Hz, 0.95 amp
or 230VAC, 50/60Hz, 0.6 amp.
• Inputfuserated@5amp/250V.
Output:
• Outputoptions:
- DC1 - 12VDC or 24VDC @ 3 amp
and DC2 - 12VDC @ 1 amp.
Note:IfDC2isnotused,DC1ratingis
12VDC or 24VDC rated @ 4 amp max.
• Filteredandelectronicallyregulatedoutput.
• Shortcircuitandthermaloverloadprotection.
Battery Backup:
• Built-inchargerforsealedleadacidorgeltypebatteries.
Battery Backup (cont’d):
• Automaticswitchovertostand-bybatterywhenACfails.
• Maximumchargecurrent0.7amp.
Supervision:
• ACfailsupervision(form“C”contacts).
• Lowbatterysupervision(form“C”contacts).
Visual Indicators:
• ACinputandDCoutputLEDindicators.
Features:
• PowerON/OFFswitch(interruptsmains)(Fig. 1c, pg. 2).
• Includesbatteryleads.
Board Dimensions (W x L x H):
4.5”x7.25”x1.75”(114.3mmx184.1mmx44.45mm).
LED Diagnostics:
Red (DC1) Green (AC) Power Supply Status
ON ON Normal operating condition.
ON OFF Loss of AC. Stand-by battery supplying power.
OFF ON No DC output. Short circuit or thermal overload condition.
OFF OFF Loss of AC. Discharged or no stand-by battery. No DC output.
Terminal Identification:
Terminal Legend Function/Description
L, G, N Connect 115VAC/230VAC to these terminals: L to Hot, N to Neutral, G to ground.
– DC1 + DC1 - 12VDC or 24VDC @ 3 amp and DC2 - 12VDC @ 1 amp
Note:IfDC2isnotused,DC1ratingis12VDCor24VDCrated@4ampmax.
– DC2 + 12VDC @ 1 amp.
ACFAIL
NC, C, NO
IndicateslossofACpower,e.g.connecttoaudibledeviceoralarmpanel.Relaynormally
energized when AC power is present. Contact rating 1 amp @ 115VAC / 28VDC
Low Battery
NC, C, NO
Indicateslowbatterycondition,e.g.connecttoalarmpanel.Relaynormallyenergizedwhen
DC power is present. Contact rating 1 amp @ 115VAC / 28VDC.
Low battery threshold: 12VDC output threshold set @ approximately 10.5VDC,
24VDC output threshold set @ approximately 21VDC.
– BAT + Stand-by battery connections. Maximum charge rate 0.7 amp.
Fig. 1
Fig. 1a
Fig. 1b
Fig. 1c
LG N
OFF ON
OPEN - 24VDC
CLOSED - 12VDC
DC1 SETTING
LOW BAT
NC C NO NC C NO
AC FAIL --- BAT + --- DC1 +
AC DC
--- DC2 +
5A 250V
Altronix is not responsible for any typographical errors. Product specifications are subject to change without notice.
140 58th Street, Brooklyn, New York 11220 USA, 718-567-8181, fax: 718-567-9056
website: www.altronix.com, e-mail: [email protected], Lifetime Warranty, Made in U.S.A.
IIOLS120D2-Rev.062113 F27N MEMBER
OPEN - 24VDC
CLOSED - 12VDC
DC1 SETTING
OPEN 24VDC
CLOSED 12VDC
Switch Detail
OFF ON

Other Altronix Power Supply manuals

Altronix R615DC8220 Series User manual

Altronix

Altronix R615DC8220 Series User manual

Altronix LPS3AC User manual

Altronix

Altronix LPS3AC User manual

Altronix SMP3CTX User manual

Altronix

Altronix SMP3CTX User manual

Altronix Maximal11FEV User manual

Altronix

Altronix Maximal11FEV User manual

Altronix ALTV244 Operating and maintenance instructions

Altronix

Altronix ALTV244 Operating and maintenance instructions

Altronix DN200 User manual

Altronix

Altronix DN200 User manual

Altronix Trove T3MK7716S User manual

Altronix

Altronix Trove T3MK7716S User manual

Altronix AL100UL User manual

Altronix

Altronix AL100UL User manual

Altronix eFlow Series User manual

Altronix

Altronix eFlow Series User manual

Altronix ALTV2432UL3 Series User manual

Altronix

Altronix ALTV2432UL3 Series User manual

Altronix PM212 User manual

Altronix

Altronix PM212 User manual

Altronix OLS20 User manual

Altronix

Altronix OLS20 User manual

Altronix ALTV615DC8ULCB User manual

Altronix

Altronix ALTV615DC8ULCB User manual

Altronix AL175220 Series User manual

Altronix

Altronix AL175220 Series User manual

Altronix ALTV1224C4 User manual

Altronix

Altronix ALTV1224C4 User manual

Altronix R2432600UL User manual

Altronix

Altronix R2432600UL User manual

Altronix AL600ULXD User manual

Altronix

Altronix AL600ULXD User manual

Altronix eFlow104NK8QP User manual

Altronix

Altronix eFlow104NK8QP User manual

Altronix ALTV2432220 Series User manual

Altronix

Altronix ALTV2432220 Series User manual

Altronix AL300X220 Series User manual

Altronix

Altronix AL300X220 Series User manual

Altronix eFlow104NB User manual

Altronix

Altronix eFlow104NB User manual

Altronix LPS3C12X User manual

Altronix

Altronix LPS3C12X User manual

Altronix OLS180 User manual

Altronix

Altronix OLS180 User manual

Altronix AL300XB2V User manual

Altronix

Altronix AL300XB2V User manual

Popular Power Supply manuals by other brands

OCZ OCZ600SXS - MECHANICAL DRAWING Mechanical drawing

OCZ

OCZ OCZ600SXS - MECHANICAL DRAWING Mechanical drawing

Velleman K7200 manual

Velleman

Velleman K7200 manual

PS Audio Power Plant P1000 supplementary guide

PS Audio

PS Audio Power Plant P1000 supplementary guide

Helios ICT Platinum Series instruction manual

Helios

Helios ICT Platinum Series instruction manual

NewMar POWER-PAC Installation & operation manual

NewMar

NewMar POWER-PAC Installation & operation manual

Rigol DP700 Series user guide

Rigol

Rigol DP700 Series user guide

Inventronics OPTOTRONIC OT Wi 35/220-240/1A0 NFC CA L quick start guide

Inventronics

Inventronics OPTOTRONIC OT Wi 35/220-240/1A0 NFC CA L quick start guide

STAMOS S-LS-88 user manual

STAMOS

STAMOS S-LS-88 user manual

Phoenix Contact FB-DP Series Configuration and setup

Phoenix Contact

Phoenix Contact FB-DP Series Configuration and setup

Kramer VA-101P12 user manual

Kramer

Kramer VA-101P12 user manual

Balluff BAE PS-XA-3Y-24-250-609-I installation guide

Balluff

Balluff BAE PS-XA-3Y-24-250-609-I installation guide

Powerfinn PAP3200HV operating manual

Powerfinn

Powerfinn PAP3200HV operating manual

Antec TruePower Quattro 1000W specification

Antec

Antec TruePower Quattro 1000W specification

INIM Electronics SmartLevel SPS24060G Installation and programming manual

INIM Electronics

INIM Electronics SmartLevel SPS24060G Installation and programming manual

Pace MBT 201A Operation & maintenance manual

Pace

Pace MBT 201A Operation & maintenance manual

EDF PPS500D user manual

EDF

EDF PPS500D user manual

Intellinet 503549 user manual

Intellinet

Intellinet 503549 user manual

COUGAR STC400 user manual

COUGAR

COUGAR STC400 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.