Honeywell®Vista™Programming
1. Set up an account in the AlulaConnect portal.
2. Add the MASTER CODE to the primary account user before connecting the BAT-Connect. This is
required for the BAT-Connect to be able to properly congure the system settings.
3. Disarm the system (all partitions).
4. Enter panel programming mode using the installer code and program the following:
5. Exit programming mode and power down the Vista system.
6. Connect the Vista system and BAT-Connect as shown in the wiring diagram on the next page.
7. For Vista 21IP panels, Internal IP/GSM jumper needs to be set to “OFF”.
8. Power up the Vista system and the BAT-Connect will automatically program it.
• The Vista system will be busy for 50-60 seconds after power up before it will
automatically program.
• BAT-Connect will set the following elds automatically:
* IP/GSM device (*29) = 1 (enabled)
* Communicate to IP/GSM device rst (*55) = 1 (IP/GSM rst)
* Opening report (*65) = 1 (enabled)
* Closing report (*66) = 1, 1 (stay closing and away closing reports enabled)
* Alarm cancel report (*68) = 1 (enabled)
* AC power restoral report (*73) = 1 (enabled)
* Low Battery restoral report (*74) = 1 (enabled)
* Phone Monitor (*92) = 0 (disabled)
9. Once the keypad(s) displays DISARMED Ready to Arm, installation is complete.
10. Verify proper operation and reporting of all event codes using your control panel’s installation
manual.
AUI 2:
• Verify that AUI2 is enabled using eld *189.
• If another device is using AUI 2, that device must rst be moved to a different AUI
address. The other device should be moved to AUI 1 for Vista 15P and AUI 1, 3, or 4 for
Vista 20P, Vista 21IP, or Safewatch Pro.
RIS:
• Vista panels that have a *91 eld that supports RIS need to have RIS disabled. No
action is required if RIS is not supported.
Keypad lockout:
• Vista 15P and 20P panel versions 10.21 and later have the keypad lockout feature
enabled by default. It is recommended this feature be disabled to prevent possible
keypad lockout conditions if the system master code in the BAT-Connect is not
synchronized with the master code in the Vista panel.
• *188 to disable keypad lockout.
• If it is required to have the keypad lockout feature enabled, it is critical that the system
master code be set up as a user for this account before connecting the module to the
panel (see step 2 above). Also, all changes to the system master code must be done at
AlulaConnect or with the Alula app, not at the Vista keypad. Failing to do this may result
in a keypad lockout condition.