American Megatrends B.O.L.T VA06 User manual

ONE-TOUCH WIRELESS HEALTH TRACKER
BODY LIFE TRACKER
User Manual
Model: VA06
Document No : AMI-PRD-UM-B-VA06
Version : 1.0
Date : 25.09.2015

B.O.L.T User Manual Model No: VA06
2
© Copyright 2015, All Rights Reserved. American Megatrends India Private Ltd.
Legal
Disclaimer
This publication/content contains proprietary information which is protected by copyright. No
part of this publication may be reproduced, transcribed, stored in a retrieval system, translated
into any language or computer language, or transmitted in any form whatsoever without the prior
written consent of the publisher. American Megatrends India Private Ltd. retains the right to
update, change or modify this publication at any time, without notice.
For Additional Information
Call American Megatrends India Private Ltd at 1800-419-9868.
Limitations of Liability
In no event shall American Megatrends India Private Ltd be held liable for any loss, expenses, or
damage of any kind whatsoever, whether direct, indirect, incidental, or consequential, arising
from the design or use of this product or the support materials provided with the product.
Limited Warranty
No warranties are made, either expressed or implied, with regard to the contents of this work, its
merchantability, or fitness for a particular use. American Megatrends India Private Ltd assumes
no responsibility for errors and omissions or for the uses made of the material contained herein
or reader decisions based on such use.
Trademark and Copyright Acknowledgments
Copyright © 2015 American Megatrends India Private Ltd. All Rights Reserved.
AMERICAN MEGATRENDS INDIA PRIVATE LTD.,
KUMARAN NAGAR,
SEMMANCHERY VILLAGE,
CHENNAI (TN) 600119.
All product names used in this publication are for identification purposes only and are
trademarks of their respective companies.

B.O.L.T User Manual Model No: VA06
3
© Copyright 2015, All Rights Reserved. American Megatrends India Private Ltd.
B.O.L.T VA06 User Manual
Model VA06 –NIBP Monitor (Systole Diastole Pulse Rate), Infrared Ear
Thermometer (Temperature), Pulse Oximeter (SpO2 & Pulse Rate),
Gluchobin (Blood Glucose, Blood Cholesterol & Blood Hemoglobin
Levels)
Thank you very much for purchasing B.O.L.T the One -Touch Wireless Health Tracker. Please read
this User Manual thoroughly to ensure safe and correct use of the product. Please keep this User
Manual for future reference.
B.O.L.T is a medical gadget with NiBP (Non-invasive Blood Pressure), SpO2 (Pulse Oximeter)
Infrared Thermometer (IRT) and Gluchobin (Invasive) combined into a small form factor device which
gets controlled from a mobile device. B.O.L.T is a cloud enabled solution. With B.O.L.T your health
vitals can be stored in your personal health cloud. For B.O.L.T to be in your hands, all you need is any
leading mobile device that operates with the compatible Operating System.

B.O.L.T User Manual Model No: VA06
4
© Copyright 2015, All Rights Reserved. American Megatrends India Private Ltd.
Table of Contents
Safety Measures....................................................................................... 5
Warning .............................................................................................. 5
Caution ............................................................................................... 5
Care and Maintenance............................................................................. 6
Know Your Unit........................................................................................ 6
Intended use ........................................................................................... 7
Prerequisites........................................................................................... 7
Using B.O.L.T Application........................................................................... 7
Blood Pressure Measurement Procedures ...................................................... 7
Blood Pressure Classification for Adults ..................................................... 9
Blood Oxygen Level Measurement Procedures ............................................... 10
Blood Oxygen Level Classification............................................................ 11
Temperature Measurement Procedures......................................................... 11
Temperature Classification......................................................................12
Blood Glucose Level Measurement Procedures .............................................. 13
Blood Glucose Level Classification ........................................................... 15
Blood Hemoglobin Level Measurement Procedures.......................................... 16
Blood Hemoglobin Level Classification ...................................................... 18
Blood Cholesterol Level Measurement Procedures .......................................... 19
Blood Cholesterol Level Classification....................................................... 21
Replacement of Battery Pack...................................................................... 23
Explanation of Indicators/Symbols............................................................... 24
Technical Specifications ...........................................................................26
Warranty Information................................................................................ 27
Customer Care Support ............................................................................ 27

B.O.L.T User Manual Model No: VA06
5
© Copyright 2015, All Rights Reserved. American Megatrends India Private Ltd.
Safety Measures
Warning
If you encounter any problem while taking blood pressure measurement, such as inflation
does not stop or air leakage in the cuff, remove the cuff or pull out the air tube from the base
unit.
Do not wrap BP cuff over the arm where an intravenous injection or transfusion is being given
to the patient.
Do not operate the gadget in places where inflammable gas, such as highly inflammable
anesthetic, may be generated or in a high-pressure oxygen room or in an oxygen tent.
Keep the gadget away from infants, small children or anyone who are incapable of using the
gadget in the correct manner.
Please do not use the same cuff for patients who are highly infectious as this practice may
cause cross-infection.
Make sure the ear canal is clean for before performing temperature measurement.
Use dust cover for Ear Thermometer during the temperature measurement.
Place the finger inside the SpO2 probe properly during the Blood oxygen level measurement.
Lancet needle, Glucose strips, Hemoglobin strips, and Cholesterol strips are meant for single
user / Single use only.
Lancet is to be used only on the tip of finger and not anywhere else.
Do not set the pricking lancet at a higher penetration depth unless it is necessary for a thicker
skin.
Caution
Do not use the gadget while moving in a vehicle as this may result in erroneous readings.
Do not use any other branded cuffs as this may result in reading errors.
Do not use unauthorized parts and accessories.
Do not store or use this gadget in locations which are maintained above the specified
temperature and humidity ranges.
Finger nail polish or false fingernails may cause inaccurate SpO2 readings.
SpO2 measurements may be adversely affected in the presence of high ambient light.
Dispose the used lancet pin and cotton in an appropriate container.
Use only American Megatrends India Specified batteries and charging devices.

B.O.L.T User Manual Model No: VA06
6
© Copyright 2015, All Rights Reserved. American Megatrends India Private Ltd.
Care and Maintenance
Store the gadget and the components in a clean and safe location.
Changes or modifications not approved by the manufacturer will void the user warranty.
Keep the accessories and gadget away from rain, sweat and water.
Do not disassemble, repair or modify the gadget and the components by yourself, hence this
could void the user's authority to operate the device.
Clean the rubber touching the finger inside the SpO2 probe gently by a soft cloth dampened
with 70% isopropyl alcohol before measurement.
Store the test strips at room temperature between 2°C to 32°C(36°F to 90°F).
Do not refrigerate or freeze the test strips.
Keep the test strips slot of the Gluchobin device free from dust.
After pulling out the test strip from its container, seal the cap of the container tightly to protect
test strips.
Know Your Unit
The base unit has an elegant look and feel with two LED indicators, an accessory connector and a
power ON/OFF sliding switch as shown below. Accessories like cuff, IR Ear Thermometer with cover,
SpO2 probe, Gluchobin and USB cable with power adapter are provided along with the base unit.
Features of the Product
Elegant design enables simple and easy use of the product.
Multiple Platform Support and same application for multiple users.
Secured Cloud application to share and manage trends with health data.
Monitor and share your health trends with doctor and loved ones.
Safe and convenient to use.

B.O.L.T User Manual Model No: VA06
7
© Copyright 2015, All Rights Reserved. American Megatrends India Private Ltd.
Intended use
B.O.L.T (VA06)
It is used to measure the vital signs like Blood Pressure, Body temperature, Blood oxygen
saturation level & Blood glucose, hemoglobin, cholesterol levels. The B.O.L.T device is controlled
from a mobile device.
Prerequisites
Some basic requirements must be adopted as mentioned below to ensure better operation of the
product.
B.O.L.Tis designed to be operated with applications like Android, iOS or Windows.
The Android OS version of the using computer/mobile device should be 4.0 or higher.
The iOS version of the using computer/mobile device should be 7 or higher.
The Windows OS version of the using computer/mobile device should be 8 or higher.
Using B.O.L.T Application
Downloading and Installing B.O.L.T application in your computer/mobile device
1. Download and Install B.O.L.T application from the Play store/Application store/Windows
application market.
2. On successful installation, launch the B.O.L.T application in the mobile device.
3. Create a User Name with your Email ID or use Facebook/Google+ Credentials for login.
4. On successful Login, provide permission for cloud service by enabling the Save in cloud
option and enter near and dear details under settings panel at left top corner of the home
view.
Note: You can also login as a guest user while internet unavailability
which might not store the measured vital parameters in the cloud storage
space on the measured parameters.
Blood Pressure Measurement Procedures
Mandatory instructions to be followed during blood pressure measurement
Relax yourself in a comfortable position.
Avoid eating, exercising and smoking for 30 minutes before taking a measurement.
Avoid taking measurements during stressful times.
Remove tight-fitting clothing from the right upper arm.
Sit in a chair with your feet flat on the floor and place the right arm on a table as shown below.

B.O.L.T User Manual Model No: VA06
8
© Copyright 2015, All Rights Reserved. American Megatrends India Private Ltd.
Apply the cuff to the right upper arm so that the cuff is wrapped at the same level of your
heart.
Ensure that the arrow present in the BP cuff points towards the artery along the middle finger
of the right hand as shown below.
Stay calm without shaking the hand during the measurement.
Blood Pressure measurement with B.O.L.T
B.O.L.T enables connecting an air hose through which the blood pressure is monitored.
Connecting air hose with the gadget and launching B.O.L.T application
1. Insert the BP connector plug into the BP socket firmly as shown above.
2. Switch ON the gadget using the ON/OFF sliding switch.
3. Enable Bluetooth and Internet Connectivity in the computer/mobile device.
4. Launch the B.O.L.T application in the computer/mobile device.
5. Login with the User Name and Password which is used for the registration.

B.O.L.T User Manual Model No: VA06
9
© Copyright 2015, All Rights Reserved. American Megatrends India Private Ltd.
Measuring BP with B.O.L.T
1. On successful login of the B.O.L.T application, Select “How is my health” option to perform
Master Health checkup or select “Check Vitals” option to perform individual test.
2. Confirm the Bluetooth device to turn-on.
3. Select the B.O.L.T device from the list of available Bluetooth devices and confirm.
4. Provide default password (1234/0000) for pairing your B.O.L.T device with mobile device on
your first time usage (only for android).
5. Wrap the cuff around the upper arm of the right hand above the elbow.
6. Ensure that the arrow in the BP cuff points the artery along the middle finger of the right hand
as discussed earlier in the Blood Pressure measurement procedure section.
7. Start the Blood Pressure measurement using the application screen.
8. Ensure that the person remains stable until the application displays the results.
9. On successful measurement, the Blood Pressure and Pulse rate are displayed and a copy of
reading will be mailed to your Near & Dear mail IDs on saving the data.
10. Multiple readings can be taken with atleast 1 minute interval by selecting the auto-reading
option.
Note: On Successful pairing of the mobile device, Bluetooth light stops
blinking in the gadget. Ensure that the save option is enabled for storing
the data in cloud.
Blood Pressure Classification for Adults
The World Health Organization (WHO) has created the following classification for assessing high
blood pressure (Hypertension). Please note that this table can give only a generic view as other
factors such as diabetes, obesity and smoking, also need to be considered for understanding the
different ranges. Consult with your physician for accurate assessment.
Blood Pressure Classification
Systole
Diastole
Low
<110
<75
Normal
110-120
75-80
Pre-Hypertension (mild)
120-139
80-89
Stage 1 Hypertension (high)
140-159
90-99
Stage 2 Hypertension (severe)
>159
>99

B.O.L.T User Manual Model No: VA06
10
© Copyright 2015, All Rights Reserved. American Megatrends India Private Ltd.
Blood Oxygen Level Measurement Procedures
Mandatory instructions to be followed during blood oxygen level measurement
Relax yourself in a comfortable position.
Remain stable during the measurement.
Place the finger properly inside the SpO2 probe.
Clean the surface of the fingertip before the measurement.
Blood Oxygen Level measurement with B.O.L.T
B.O.L.T enables connecting a SpO2 probe through which the blood oxygen level is measured.
Connecting SpO2 probe with the gadget
Insert the SpO2 connector into the socket firmly as shown below.
Note: Ensure to clean your hands before taking SpO2 measurement. Some SpO2
reading fluctuation may be occurred of below 85% for certain ethnicity
group.
If the SpO2 values are deviated below 70% or above 100%, ensure that the
user positions his finger properly as shown below.
Measuring Blood Oxygen Level with B.O.L.T
1. Clean the rubber pad of the SpO2 probe touching the finger gently by a soft cloth dampened
with 70% isopropyl alcohol and let air dry or use soft dry cloth to clean before measurement.

B.O.L.T User Manual Model No: VA06
11
© Copyright 2015, All Rights Reserved. American Megatrends India Private Ltd.
2. Clean your hands with hand wash before the measurement.
3. Select “Check Vitals” option to perform individual test.
4. Clip the SpO2 probe in the index finger of the person to be measured in right/left hand as
displayed above.
5. Select the Blood Oxygen option from the application screen.
6. On successful measurement, the SpO2 value and Pulse rate are displayed and a copy of
reading will be mailed to your Near & Dear mail IDs on saving the data.
Blood Oxygen Level Classification
Please note that this table can give only a generic view. Consult with your physician for accurate
assessment.
SpO2 Classification
Range
Hypoxemia (low)
< 95 %
Normal
95-100 %
Temperature Measurement Procedures
Mandatory instructions to be followed during temperature measurement
Relax yourself in a comfortable position.
Use new dust cover for each measurement.
Place the Ear Thermometer firmly into the ear canal for accurate measurement.
Remain stable during the measurement.
Wait until the application displays the measured temperature.
Body Temperature measurement with B.O.L.T
B.O.L.T enables connecting an IR Ear Thermometer through which the temperature is measured.
Connecting IR Ear Thermometer with the gadget
Insert the IR Ear Thermometer connector into the socket firmly as shown below.

B.O.L.T User Manual Model No: VA06
12
© Copyright 2015, All Rights Reserved. American Megatrends India Private Ltd.
Measuring Body Temperature with B.O.L.T
1. Select “Check Vitals” option to perform individual test.
2. Use dust cover over the tip of the Ear Thermometer.
3. Place the Ear Thermometer inside the ear horizontally as such the pointer maintains
horizontal position as displayed above.
4. Select the Body temperature option from the application screen.
5. On successful measurement, the temperature value is displayed and a copy of the
reading will be mailed to your Near & Dear mail IDs on saving the data.
Temperature Classification
Please note that this table can give only a generic view. Consult with your physician for
accurate assessment.
Temperature Classification
Range
Hypothermia
<36.3 °C (< 97.5 °F)
Normal
36.4 –37.5 °C (97.6- 99.5 °F)
Hyperthermia
>37.5.°C (>99.5 °F)

B.O.L.T User Manual Model No: VA06
13
© Copyright 2015, All Rights Reserved. American Megatrends India Private Ltd.
Blood Glucose Level Measurement Procedures
Mandatory instructions to be followed during the measurement
Relax yourself in a comfortable position.
Blood Glucose level measurement with B.O.L.T
B.O.L.T enables connecting a Gluchobin through which the glucose test strip are inserted for
measurement.
Using Lancet pen and Lancet
1. Unscrew and remove the lancet pen `s adjustable tip as shown below.
2. Insert a lancet into the carrier as shown below.
3. Twist off the protective cover.

B.O.L.T User Manual Model No: VA06
14
© Copyright 2015, All Rights Reserved. American Megatrends India Private Ltd.
4. Replace the adjustable tip tightly. Choose a desired skin penetration depth by rotating the top
portion of the adjustable tip until the setting number lines up to the arrow.
5. Settings are based on skin type:
Depth 1-2 for soft or thin skin
Depth 3 for average skin
Depth 4-5 for thick or calloused skin
6. Hold the tip of the lancet pen with one hand and pull the sliding barrel with the other hand.
When a click is felt, the trigger rises up. Release the sliding barrel, it will move back to its
original position.
Connecting Gluchobin with the gadget
7. Insert the Gluchobin connector into the socket firmly as shown below.
Gluchobin connected to B.O.L.T Device
8. Select Gluchobin and choose the “Glucose” option from the application screen of the mobile
device.
9. Insert the blood glucose test strip into the test strip slot of the Gluchobin as shown below.
10. Click “Start” in the application screen of the mobile device.
11. Clean your finger with alcohol swap and let it dry completely.
12. Place the lancet pen on side of your fingertip.
13. Press the trigger on the lancet pen as shown above.
14. Get a drop of blood and place the blood drop on the test strip target area.

B.O.L.T User Manual Model No: VA06
15
© Copyright 2015, All Rights Reserved. American Megatrends India Private Ltd.
15. On successful test completion, the test result will be displayed in 6 or 7 second on the
application screen.
16. Wipe any excess blood on the finger with the cotton and dispose it properly.
17. Choose the options “before meal” or “just after meal” or “3 hours after meal” as per the status
of the user in the application screen.
18. Pull the test strip out of the Gluchobin.
19. Unscrew the adjustable tip of the lancet pen.
20. Place the protective cover of the lancet back on the lancet as shown below.
21. Discard the used lancet in an appropriate container.
22. Screw the adjustable tip back on the lancet pen.
Note: Ensure that the test strip gets enough blood. Else try to use a new
test strip to do the test again.
To avoid accidental injury, always remove the used lancet immediately after
each test.
Blood Glucose Level Classification
Blood Glucose Classification
Before Meal
3 Hours after meal
Normal
70-100
70-140
Pre-Diabetic
101-125
141-200
Diabetic
126 & above
200 & above

B.O.L.T User Manual Model No: VA06
16
© Copyright 2015, All Rights Reserved. American Megatrends India Private Ltd.
Blood Hemoglobin Level Measurement Procedures
Mandatory instructions to be followed during the measurement
Relax yourself in a comfortable position.
Blood Hemoglobin level measurement with B.O.L.T
B.O.L.T enables connecting a Gluchobin through which the hemoglobin test strip are inserted for
measurement.
Using Lancet pen and Lancet
1. Unscrew and remove the lancet pen `s adjustable tip as shown below.
2. Insert a lancet into the carrier as shown below.
3. Twist off the protective cover.
4. Replace the adjustable tip tightly. Choose a desired skin penetration depth by rotating the top
portion of the adjustable tip until the setting number lines up to the arrow.
5. Settings are based on skin type:
Depth 1-2 for soft or thin skin

B.O.L.T User Manual Model No: VA06
17
© Copyright 2015, All Rights Reserved. American Megatrends India Private Ltd.
Depth 3 for average skin
Depth 4-5 for thick or calloused skin
6. Hold the tip of the lancet pen with one hand and pull the sliding barrel with the other hand.
When a click is felt, the trigger rises up. Release the sliding barrel, it will move back to its
original position.
Connecting Gluchobin with the gadget
7. Insert the Gluchobin connector into the socket firmly as shown below.
Gluchobin connected to B.O.L.T Device
8. Select Gluchobin and choose the “Hemoglobin” option from the application screen of the
mobile device.
9. Insert the hemoglobin test strip into the test strip slot of the Gluchobin as shown below.
10. Click “Start” in the application screen of the mobile device.
11. Clean your finger with alcohol swap and let it dry completely.
12. Place the lancet pen on side of your fingertip.
13. Press the trigger on the lancet pen as shown above.
14. Get a drop of blood and place the blood drop on the test strip target area.

B.O.L.T User Manual Model No: VA06
18
© Copyright 2015, All Rights Reserved. American Megatrends India Private Ltd.
15. On successful test completion, the test result will be displayed in few seconds on the
application screen.
16. Wipe any excess blood on the finger with the cotton and dispose it properly.
17. Pull the test strip out of the Gluchobin.
18. Unscrew the adjustable tip of the lancet pen.
19. Place the protective cover of the lancet back on the lancet as shown below.
20. Discard the used lancet in an appropriate container.
21. Screw the adjustable tip back on the lancet pen.
Note: Ensure that the test strip gets enough blood. Else try to use a new
test strip to do the test again.
To avoid accidental injury, always remove the used lancet immediately after
each test.
Blood Hemoglobin Level Classification
Population
Non –
Anemic
g/dl
Mild
g/dl
Moderate
g/dl
Severe
g/dl
Children 6 - 59 months of age
>11.0
10.0 –10.9
7.0 –9.9
< 7.0
Children 5 - 11 years of age
>11.5
11.0 –11.4
8.0 –10.9
< 8.0
Children 12 - 14 years of age
>12.0
11.0 –11.9
8.0 –10.9
< 8.0
Non-pregnant women
>12.0
11.0 –11.9
8.0 –10.9
< 8.0
Pregnant women
>11.0
10.0 –10.9
7.0 –9.9
< 7.0
Men (15 years of age and above)
>13.0
11.0 –12.9
8.0 –10.9
< 8.0

B.O.L.T User Manual Model No: VA06
19
© Copyright 2015, All Rights Reserved. American Megatrends India Private Ltd.
Blood Cholesterol Level Measurement Procedures
Mandatory instructions to be followed during the measurement
Relax yourself in a comfortable position.
Blood Cholesterol level measurement with B.O.L.T
B.O.L.T enables connecting a Gluchobin through which the cholesterol test strip are inserted for
measurement.
Using Lancet pen and Lancet
1. Unscrew and remove the lancet pen `s adjustable tip as shown below.
2. Insert a lancet into the carrier as shown below.
3. Twist off the protective cover.

B.O.L.T User Manual Model No: VA06
20
© Copyright 2015, All Rights Reserved. American Megatrends India Private Ltd.
4. Replace the adjustable tip tightly. Choose a desired skin penetration depth by rotating the top
portion of the adjustable tip until the setting number lines up to the arrow.
5. Settings are based on skin type:
Depth 1-2 for soft or thin skin
Depth 3 for average skin
Depth 4-5 for thick or calloused skin
6. Hold the tip of the lancet pen with one hand and pull the sliding barrel with the other hand.
When a click is felt, the trigger rises up. Release the sliding barrel, it will move back to its
original position.
Connecting Gluchobin with the gadget
7. Insert the Gluchobin connector into the socket firmly as shown below.
Gluchobin connected to B.O.L.T Device
8. Select Gluchobin and choose the “Cholesterol” option from the application screen of the
mobile device.
9. Insert the cholesterol test strip into the test strip slot of the Gluchobin as shown below.
10. Click “Start” in the application screen of the mobile device.
11. Clean your finger with alcohol swap and let it dry completely.
12. Place the lancet pen on side of your fingertip.
13. Press the trigger on the lancet pen as shown above.
14. Get a drop of blood and place the blood drop on the test strip target area.
Table of contents
Other American Megatrends Health Care Product manuals
Popular Health Care Product manuals by other brands

Expain
Expain CHANGE X user manual

SEVERIN
SEVERIN GS 7521 Dimensions

BIOTRONIK
BIOTRONIK CardioMessenger II-S Technical manual

JCS Wellness Solutions
JCS Wellness Solutions myself Use & care guide

Rumidimur
Rumidimur RecoveRay Sport Instructions for use

Stryker
Stryker EOLE DC 32" Operation and maintenance manual