Amit RB-MVB/AN02 User manual

rb-mvban02_g_en_100
RB-MVB/AN02
MVB analyser
Operation manual
Version 1.00

RB-MVB/AN02
rb-mvban02_g_en_100 2/30
AMiT, spol. s r. o. does not provide any warranty concerning the contents of this
publication and reserves the right to change the documentation without
obligation to inform any body or authority about it.
This document can be copied and redistributed under following conditions:
1. The whole text (all pages) must be copied without any changes.
2. All redistributed copies must retain the AMiT, spol. s r. o. copyright notice
and any other notices contained in the documentation.
3. This document must not be distributed for purpose making of profit.
The names of products and companies used herein can be trademarks or
registered trademarks of their respective owners.
AMiT is a registered trademark.
Copyright (c) 2016, AMiT, spol. s r. o.
Producer: AMiT, spol. s r. o.
Naskové 1100/3, 150 00 Praha
www.amit-transportation.com

RB-MVB/AN02
3/30 rb-mvban02_g_en_100
Contents History of revisions.........................................................................................4
Related documentation...................................................................................4
1. Definition of used abbreviaions .........................................................5
2. Definition of used terms......................................................................6
3. Introduction..........................................................................................7
4. Technical parameters..........................................................................8
4.1. Dimensions...................................................................................................10
4.2. Recommended drawing symbol ...................................................................11
5. Product marking ................................................................................12
5.1. Producer type label.......................................................................................13
6. Conformity assessment ....................................................................14
6.1. Other tests....................................................................................................15
7. Power supply......................................................................................16
8. Communication lines.........................................................................17
8.1. MVB-ESD.....................................................................................................17
8.2. MVB-EMD ....................................................................................................18
8.2.1 MVB line state indication..............................................................................19
8.3. Ethernet........................................................................................................20
8.3.1 Ethernet line state indication ........................................................................21
9. Inputs/outputs....................................................................................22
9.1. Trigger output...............................................................................................22
10. Indications and settings....................................................................23
10.1. System LEDs................................................................................................23
10.2. Service mode and factory setting .................................................................24
10.3. Mounting, installation rules...........................................................................25
11. Ordering information and completion .............................................26
11.1. Completion ...................................................................................................26
12. Packing ...............................................................................................27
13. Storing.................................................................................................28
14. Maintenance .......................................................................................29
15. Waste disposal...................................................................................30

RB-MVB/AN02
rb-mvban02_g_en_100 4/30
History of revisions
Document name: rb-mvban02_g_en_100.pdf
Revision
Date
Author of change
Changes
100
4. 10. 2016
Petrovský J.
New document
Related documentation
1. RB-MVB/AN02 –MVB analyser –Programmers manual
file: rb-mvban02_1_ms_en_100.pdf

RB-MVB/AN02
5/30 rb-mvban02_g_en_100
1. Definition of used abbreviaions
Bus Administrator
Electrical Middle Distance
Medium Attachment Unit
Multifunction Vehicle Bus
Message Data
Process Data
To Be Defined
Train Communication Network
BA
EMD
MAU
MVB
MD
PD
TBD
TCN

RB-MVB/AN02
rb-mvban02_g_en_100 6/30
2. Definition of used terms
Bus Administrator
MVB device with Bus Administrator functionality is able to work as MVB bus
Master. This function supposes the device is able to transfer the process data
and reports as well as transmit and receive the Device Status type information.
Electrical Middle Distance
This is a type of physical interface of MVB line, where a twisted pair of shielded
wires is used for interconnection with implementing of transformer coupling for
galvanic isolation. EMD medium is used for up to 32 nodes and for distances to
200 m.
Electrical Short Distance
Type of physical interface of the MVB line, with shielded twisted pair, used for
connection. Usage of galvanic isolation is not a mandatory, but some
implementations offer possibility of galvanic isolation. ESD medium is used for
up to 32 nodes on up to a distance of 20 m.
TCN Gateway
MVB device with TCN Gateway function is able to access to other buses. This
function supposes the device is able to transfer the process data and reports as
well as transmit and receive the Device Status type information.

RB-MVB/AN02
7/30 rb-mvban02_g_en_100
3. Introduction
RB-MVB/AN02 is an MVB analyser. Analyser contains doubled MVB interface
in ESD and EMD connection, Ethernet interface and BNC connector for
triggering.
Device is supplied from factory only with loader. Before first use all required
domains must be loaded into device (see Programming manual).
2 × MVB interface (in EMD and ESD version, doubled line)
1 × Ethernet 10/100 Mbps interface, RJ45
1 ×output trigger with BNC connector
Power supply voltage 24 V DC
Design according to EN 50155:2007
MVB interface complies with IEC 61375-3-1: 2012
Basic features

RB-MVB/AN02
rb-mvban02_g_en_100 8/30
4. Technical parameters
MVB Standard
IEC 61375-3-1: 2012
Number of MVB lines
1 × EMD, 1 × ESD
Number of MVB channels
2
MVB Classification
Class 1
Galvanic isolation
Yes
Insulation strength
500 V AC / 1 minute *)
Physical layer
EMD, ESD
Communication rate
1.5 Mbps 0.01 %
Max. number of devices
32
Max. segment length without repeater
200 m for EMD / 20 m for ESD
Characteristic impedance
120 Ω 0.10 % **)
Connection point
2 × 2 D-sub DE-9 (concatenation)
connector fixing by M3 bolt
*) Isolation must not be used for dangerous voltage separation.
**) Terminators are included.
Voltage level
5 V
Output impedance
50 Ω
Connection point
BNC connector
Number of ports
1
Data communication rate
10/100 Mbps
Galvanic isolation
Yes
Galvanic isolation strength
500 V AC / 1 minute *)
Connection point
RJ45 connector according to IEEE802.3
Recommended cabling
STP CAT5
Maximum segment length
100 m
Nominal power supply voltage
24 V DC
Power supply voltage range
16.8 V to 33.6 V DC
Power consumption
Max. 0.6 A at 24 V DC
Starting peak current
Max. 15 A / < 1 ms at 24 V DC
Galvanic isolation
Yes
Insulation strength
500 V AC / 1 minute *)
Connection point
Connector WAGO 769-103/021-000
Wire cross section
0.5 mm2 to 4 mm2
*) Isolation must not be used for dangerous voltage separation.
Mechanical design
Metal case
Surface finish
Powder coating
Colour
RAL7035
Mounting
2 × ø 6 mm hole
Ingress protection rate
IP20
Weight –netto
–brutto
0.9 kg ±5 %
1.14 kg ±5 %
Dimensions (w × h × d)
(50 × 228 × 113) mm
Package dimensions (w × h × d)
(260 × 180 × 115) mm
MVB interface
Trigger output
Ethernet
Power supply
Mechanics

RB-MVB/AN02
9/30 rb-mvban02_g_en_100
Unit overall mass of plastics
144 g
Included mass of self-extinguishing
plastics
144 g
Module does not contain
PUR, PVC, Asbestos
Module complies
2011/65/EU (ROHS)
1907/2006EU (REACH)
Operating temperature
-40 °C to 70 °C
Storage temperature
-40 °C to 70 °C
Maximum ambient humidity
< 95 % non-condensing
Expected MTBF
> 150 000 h
Expected lifetime
15 years
None
Equipment is intended to operate up to 1 400 m above the sea level.
Equipment is designed to meet the Temperature Class TX.
According to EN 61373:2010 standard, the equipment is classified in terms of
vibrations into Category 1, Class A (mounting to vehicle body).
Permissible supplying voltage drop-outs duration: max 10 ms (Class S2 according to
Chapter 3.1.1.2 of EN 50155:2007).
For supply voltage switching are permissible conditions of C1 and C2 Class.
The device is not classified according to EN 50128:2011 Railway applications –
Communications, signalling and processing systems –Software for railway control
and protection systems.
The device is not classified according to EN 50129:2003 Railway applications –
Communication, signalling and processing systems –Safety related electronic
systems for signalling.
Device is supplied with loader, which enables software downloading using ADS
Manager application via serial service line.
Dangerous
materials
Temperatures
Others
Components
with reduced
lifetime
Claims EN
50155:2007
Safety
classification
Software

RB-MVB/AN02
rb-mvban02_g_en_100 10/30
4.1. Dimensions
xxxxxxx
S/N:
WEIGHT:
0.87 kg
DATE:
09.06.2015
MAC:
xx-xx-xx-xx-xx-xx
HiPot:
HiPot - OK
TEST:
OK-JE
LDR:
1.0
POWER:
24 V DC / 0.6 A
TYPE:
RB-MVB/AN02
50
187
203
228
6
78
113
Fig. 1 - RB-MVB/AN02 mechanical dimensions in mm

RB-MVB/AN02
11/30 rb-mvban02_g_en_100
4.2. Recommended drawing symbol
Following drawing symbol is recommended for RB-MVB/AN02 analyser.
RB-MVB/AN02
PWR
PE
GND
Vcc
X1
1
2
3
X2
Ethernet
X4
MVB ESD
X3
MVB ESD
X5
Trigger
X7
MVB EMD
X6
MVB EMD
Fig. 2 - Recommended drawing symbol for RB-MVB/AN02

RB-MVB/AN02
rb-mvban02_g_en_100 12/30
5. Product marking
Analyser RB-MVB/AN02 is fitted with producer type label on its side.
xxxxxxx
S/N:
WEIGHT:
0.87 kg
DATE:
09.06.2015
MAC:
xx-xx-xx-xx-xx-xx
HiPot:
HiPot - OK
TEST:
OK-JE
LDR:
1.0
POWER:
24 V DC / 0.6 A
TYPE:
RB-MVB/AN02
1
Fig. 3 - Label location
Number
Description
1
Type label
Legend

RB-MVB/AN02
13/30 rb-mvban02_g_en_100
5.1. Producer type label
The unit has a producer type label attached to its rear side. Data located on
type label are listed in the table above, for example of label design see Fig. 4 -
Example of AMiT type label.
Description
Data
Note
–
Logo AMiT
Producer logo
–
QR code
Producer QR code
TYPE
RB-MVB/AN02
Product type designation
S/N
xxxxxxx
Serial number
MAC
xx-xx-xx-xx-xx-xx
X2 interface MAC address
LDR
1.0
Loader version
POWER
24 V DC / 0.6 A
Power supply voltage / Consumption
WEIGHT
0.87 kg
Weight
TEST
OK-xx
Routine testing result
HiPot
HiPot-OK
HiPot test result
Date
dd.mm.yyyy
Production date
–
Logo CE
The product is in compliance with EU
legislation and directives
–
Crossed out dustbin logo
Disposal of the product is a subject to
regulations on the disposal of electronic
waste
xxxxxxx
S/N:
WEIGHT:
0.87 kg
DATE:
09.06.2015
MAC:
xx-xx-xx-xx-xx-xx
HiPot:
HiPot - OK
TEST:
OK-JE
LDR:
1.0
POWER:
24 V DC / 0.6 A
TYPE:
RB-MVB/AN02
Fig. 4 - Example of AMiT type label

RB-MVB/AN02
rb-mvban02_g_en_100 14/30
6. Conformity assessment
The equipment meets the requirements of NV616/2006 Czech Government
Decree. The conformity assessment has been carried out in accordance with
harmonized standard EN 50121-3-2:2006.
Tested in accordance
with standard
Type of test
Classification
EN 55011:2009
Industrial, scientific and medical
equipment –Radio-frequency
disturbance characteristics –Limits and
methods of measurement
Complies
EN 61000-4-2:2009
Electromagnetic compatibility (EMC) –
Part 4-2: Testing and measurement
techniques –Electrostatic discharge
immunity test
Complies
EN 61000-4-3:2006
Electromagnetic compatibility (EMC) –
Part 4-3: Radiated, radio-frequency,
electromagnetic field immunity test,
800 MHz to 1000 MHz
20 V/m
EN 61000-4-3:2006
Electromagnetic compatibility (EMC) –
Part 4-3: Radiated, radio-frequency,
electromagnetic field immunity test,
1000 MHz to 2100 MHz
10 V/m
EN 61000-4-3:2006
Electromagnetic compatibility (EMC) –
Part 4-3: Radiated, radio-frequency,
electromagnetic field immunity test,
2100 MHz to 2500 MHz
5 V/m
EN 61000-4-4:2012
Electromagnetic compatibility (EMC) –
Part 4-4: Testing and measurement
techniques –Electrical fast transient/burst
immunity test
2 kV
EN 61000-4-5:2006
Electromagnetic compatibility (EMC) –
Part 4-5: Testing and measurement
techniques –Electrostatic discharge
immunity test
2 kV
EN 61000-4-6:2009
Electromagnetic compatibility (EMC) –
Part 4-6: Testing and measurement
techniques –Immunity to conducted
disturbances, induced by radio-frequency
fields
10 V

RB-MVB/AN02
15/30 rb-mvban02_g_en_100
6.1. Other tests
This product has been assessed and approved for use in railway applications
according to standards:
Tested in accordance
with standard
Type of test
Classification
EN 50155:2007
Railway applications –Electronic
equipment used on rolling stock
Complies
EN 61373:2010
Railway applications –Rolling stock
equipment –Shock and vibration tests
Complies
EN 60068-2-1:2007
Environmental testing –Part 2-1: Tests –
Test A: Cold
Complies
EN 60068-2-2:2007
Environmental testing –Part 2-2: Tests –
Test B: Dry heat
Complies
EN 61000-4-29:2000
Electromagnetic compatibility (EMC) –
Part 4-29: Testing and measurement
techniques –Voltage dips, short
interruptions and voltage variations on
d.c. input power port immunity tests
Complies
IEC 61335-3-2
IEC 61375-3-2 ed. 1: Electronic railway
equipment –Train Communication
Network (TCN) –Part 3-2:
MVB Multifunction Vehicle Bus
conformance testing
Complies

RB-MVB/AN02
rb-mvban02_g_en_100 16/30
7. Power supply
Analyser RB-MVB/AN02 can be powered only by DC power supply +24 V.
X1
Fig. 5 - Power supply connector location
Connector type: WAGO 769-103/021-000
Connector
Pin
Signal
Description
X1
1
PE
Module chassis
2
GND
Power supply, ground
3
Vcc
Power supply, +24 V DC
Connector
wiring

RB-MVB/AN02
17/30 rb-mvban02_g_en_100
8. Communication lines
Analyser RB-MVB/AN02 disposes with MVB interfaces adapted for EMD
(Electrical Middle Distance) and ESD (Electrical Short Distance).
Coupling connector is D-sub DE-9 plug and socket, fixed to counterpart by bolt
with M3 thread. Connectors are internally concatenated.
8.1. MVB-ESD
Terminating resistors for ESD are included in TRM-MVB/F ESD and TRM-
MVB/M ESD.
X3, X4
Fig. 6 - Location of MVB-ESD connectors
Connector type: D-sub DE-9, plug
Connector
Pin
Signal
Description
X3, X4
1
A.Data_P
A line positive wire
2
A.Data_N
A line negative wire
3
–
Not used
4
B.Data_P
B line positive wire
5
B.Data_N
B line negative wire
6
A1_0V
External terminator power supply
7
B1_0V
External terminator power supply
8
A1_5V
External terminator power supply
9
B1_5V
External terminator power supply
Shielding
SH_MVB
Connected to PE
Connectors
wiring

RB-MVB/AN02
rb-mvban02_g_en_100 18/30
8.2. MVB-EMD
Terminating resistor for EMD is part of analyser. It is activated through external
termination module TRM-MVB/F EMD or TRM-MVB/M EMD.
X6, X7
Fig. 7 - Location of MVB-EMD connectors
Connector type: D-sub DE-9, socket
Connector
Pin
Signal
Description
X6, X7
1
A.Data_P
A line positive wire
2
A.Data_N
A line negative wire
3
-
Not used
4
B.Data_P
B line positive wire
5
B.Data_N
B line negative wire
6
A.Term_P
A line termination, positive pole
7
A.Term_N
A line termination, negative pole
8
B.Term_P
B line termination, positive pole
9
B.Term_N
B line termination, negative pole
Shielding
SH_MVB
Connected to PE
Connector
wiring

RB-MVB/AN02
19/30 rb-mvban02_g_en_100
8.2.1 MVB line state indication
State of MVB line is indicated by 8 LEDs on front panel. Following table
describes meaning of individual LEDs.
Fig. 8 - Detail look on front panel LEDs (MVB LEDs)
LED
Colour
TA
Green
TB
Green
AA
Green
AB
Green
DA
Yellow
DB
Yellow
MA
Green
BA
Green
LED
Description
TA
trusted line, line A
TB
trusted line, line B
AA
activity on line A
AB
activity on line B
DA
disturbance, line A
DB
disturbance, line B
MA
master detect
BA
bus administrator
The MA LED lights when valid master frames are received. When Bus Timeout
event occurs, the LED goes out until receiving of next master frame.
Note:

RB-MVB/AN02
rb-mvban02_g_en_100 20/30
8.3. Ethernet
The 10/100 Mbps Ethernet interface allows connecting of RB-MVB/AN02
analyser to LAN network.
X2
Fig. 9 - Ethernet connector location
Connector type: RJ45, socket
PIN
Signal
Description
1
Tx+
Data transmission, signal +
2
Rx+
Data reception, signal +
3
Tx-
Data transmission, signal -
4
–
Not used
5
–
Not used
6
Rx-
Data reception, signal -
7
–
Not used
8
–
Not used
1 8
Fig. 10 - Wiring of RJ45 connector, front view
Connectors
wiring
Table of contents
Other Amit Measuring Instrument manuals