AMP®R7S Underwater Light (Lamp-Ready)
AUL-8006-25-B-BZ
INSTALLATION & MAINTENANCE GUIDE
www.amplighting.com
–2–
Important Safety Instructions: Read Before Installation
!
This xture is intended for installation in accordance with local codes and
the National Electric Code (NEC). Failure to adhere to these codes and
instructions may result in serious injury, property damage and void the
warranty.
These instructions do not intend to cover all variations in installation, oper-
ation maintenance or mounting situation.
1. Make sure that the power is turned OFF before installing or servicing
this xture.
2. This xture is intended to be used only with a power supply (trans-
former) rated maximum of 300 watts (25 AMPS) at 15 volts.
3. Underground Low Energy Cable must not be buried over 6” (15.2 cm)
in order to connect to the main low voltage cable.
4. Wiring connections must be made with UL Listed wire connectors that
is suitable for the application.
5. Position the UL listed wire connector so that it is located within 6 inch-
es (15.2 cm) from a building structure, a luminaire, or tting.
“WARNING - RISK OF ELECTRIC SHOCK”
• Use only in ponds and small decorative fountains where persons will
immerse no more than their hands and lower arms while the product is
energized.
• DO NOT use in water intended for swimming, wading, immersion, or
bathing.
• All installer completed cable connections must be located outside of
pond or fountain.
• Low voltage circuit must be supplied by a power unit marked as suitable
for supplying submersible luminaires.
• Power unit must be supplied by a circuit protected by a ground fault
circuit interrupter (GFCI).
• “Maximum depth: 18 in (450 mm)”.