CONNECTING THE UNIT
Page 7MxP2288 | MatriMix Paging
3. REMOTE TRIGGER ( OPTIONAL )
To Message Recorder etc, the ports are triggered using a dry contact. The action that shall
follow would be according to the setup done for the remote trigger, eg; installation of
MR1301 to MxP2288 would require an audio in and a dry contact. “Please refer to section
8” connecting MR1301.
REMOTE
PAGING MIC
M P 2288
12 x 8 ETHERNET MATRIX CONTROLLER
x
EP1200
CONNECTION
24V DC IN ; 1 A
+ -
REMOTE
PANEL 1
REMOTE
PANEL 2
CH4CH1 CH2 CH3
COM
NO
COM
NO
COM
NO
COM
NO
CONFIGURABLE REMOTE TRIGGER
EM / AC
CONT (NO)
RS485
A B
ETHERNET
PORT
MESSAGE PLAYER
IN ( LINE BAL )
-
MxP2288
It is used when external triggering device is connected
to the controller, and when activated, it shall bypass the
routed BGM-Output to the set parameter for these
ports.
There are 4 ports available in the controller.
Setting of the ports’
behavior is done through
web browser.
Please refer to the section
in “ Web browser setting ”
4. RS485 DATA
UART ( RS485 ) data available for connection to RP1104, zone decoders etc. As the unit’s controlling features can be accessed via web browser, we recommend
using this method to perform controls.
Use a cat5e cable to connect EP1200 to the controller.
Activation of EP1200 shall automatically mute all other inputs and redirect them to EP1200 for
highest priority announcement.
REMOTE
PAGING MIC
M P 2288
12 x 8 ETHERNET MATRIX CONTROLLER
x
EP1200
CONNECTION
24V DC IN ; 1 A
+ -
REMOTE
PANEL 1
REMOTE
PANEL 2
CH4CH1 CH2 CH3
COM
NO
COM
NO
COM
NO
COM
NO
CONFIGURABLE REMOTE TRIGGER
EM / AC
CONT (NO)
RS485
A B
ETHERNET
PORT
MESSAGE PLAYER
IN ( LINE BAL )
cat5e
EP1200
FAIL SAFE FEATURE
MxP2288 has advanced feature of fail safe operation. If the unit is faulty digitally or if it is
totally shut down, EP1200 shall still be able to page, bypassing the controller, feeding the
audio signal directly to power amplifiers.
Note: Connect EP1200 to the dedicated port only and NOT the “Remote Paging Mic” jack.
5. CONNECTING EP1200 EMERGENCY PAGING MIC
EP1200 can be connected directly to MxP2288 and whenever it is activated, all outputs will be overrided. Activation of EP1200 will also provide a dry contact which
will be used for variety of purpose, such as overriding volume controller, triggering All Call at external zone selectors, etc. ( See section 6 )
6. EM / AC CONTACT
REMOTE
PAGING MIC
M P 2288
12 x 8 ETHERNET MATRIX CONTROLLER
x
EP1200
CONNECTION
24V DC IN ; 1 A
+ -
REMOTE
PANEL 1
REMOTE
PANEL 2
CH4CH1 CH2 CH3
COM
NO
COM
NO
COM
NO
COM
NO
CONFIGURABLE REMOTE TRIGGER
EM / AC
CONT (NO)
RS485
A B
ETHERNET
PORT
MESSAGE PLAYER
IN ( LINE BAL )
+ VE
24V DC Overriding
VC
MxP2288
The dry contact activated upon triggering from EP1200
being used to override external volume controller
Dry contact is available for triggering external devices when EP1200 connected to MxP2288 is activated.
- VE
MESSAGE
INPUT
PRE
INPUT
MAIN
OUTPUT
POWER + AUDIO
+ DATA
18
BALANCE LINE LEVEL
8 - Audio +ve (Output)
7 - Ground
6 - Audio -ve (Output)
5 - +24V (Output) Max 300mA
4 - Ground
3 - NC
2 - Data B
1 - Data A
PIN CONFIGURATIONS :