manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. AMX
  6. •
  7. Enclosure
  8. •
  9. AMX RDA-ENC8W Assembly instructions

AMX RDA-ENC8W Assembly instructions

Other AMX Enclosure manuals

AMX Rough-In Box CB-TP15 User manual

AMX

AMX Rough-In Box CB-TP15 User manual

AMX Enova DGX 8 User manual

AMX

AMX Enova DGX 8 User manual

AMX Dimmer Enclosures w/Breakers RDA-ENC12B User manual

AMX

AMX Dimmer Enclosures w/Breakers RDA-ENC12B User manual

AMX Radia Eclipse RE-DM4 User manual

AMX

AMX Radia Eclipse RE-DM4 User manual

AMX AXB-TM5 Guide

AMX

AMX AXB-TM5 Guide

AMX Rough-In Box CB-MVP-WCS52 User manual

AMX

AMX Rough-In Box CB-MVP-WCS52 User manual

AMX RDA-ENC2 Assembly instructions

AMX

AMX RDA-ENC2 Assembly instructions

AMX RDA-ENC2 User manual

AMX

AMX RDA-ENC2 User manual

AMX Rough-In Box CB-TP10 User manual

AMX

AMX Rough-In Box CB-TP10 User manual

AMX CB-TP17 User manual

AMX

AMX CB-TP17 User manual

AMX FG5968-83 User manual

AMX

AMX FG5968-83 User manual

AMX Rough-In Box CB-TP17 User manual

AMX

AMX Rough-In Box CB-TP17 User manual

AMX RADIA DIMMER ENCLOSURES WITH BREAKERS User manual

AMX

AMX RADIA DIMMER ENCLOSURES WITH BREAKERS User manual

AMX RDA-ENC2 User manual

AMX

AMX RDA-ENC2 User manual

AMX 8-Module In-Wall Enclosure RDA-ENC8W Assembly instructions

AMX

AMX 8-Module In-Wall Enclosure RDA-ENC8W Assembly instructions

AMX CB-MXP-43-F User manual

AMX

AMX CB-MXP-43-F User manual

AMX Rough-In Box for 12" Wall/Flush Mount Touch Panels... User manual

AMX

AMX Rough-In Box for 12" Wall/Flush Mount Touch Panels... User manual

AMX RDA-ENC12B User manual

AMX

AMX RDA-ENC12B User manual

AMX AXB-TC Guide

AMX

AMX AXB-TC Guide

Popular Enclosure manuals by other brands

Antec Veris Fusion Remote Max Specification sheet

Antec

Antec Veris Fusion Remote Max Specification sheet

ENERMAX iVektor.Q ECA 3371 Series user manual

ENERMAX

ENERMAX iVektor.Q ECA 3371 Series user manual

Lindy 43095 user manual

Lindy

Lindy 43095 user manual

SICK C4000 Select operating instructions

SICK

SICK C4000 Select operating instructions

Geeek A60 PLUS installation guide

Geeek

Geeek A60 PLUS installation guide

OVE SYDNEY 48 installation manual

OVE

OVE SYDNEY 48 installation manual

SilentiumPC Armis AR5 Hardware installation

SilentiumPC

SilentiumPC Armis AR5 Hardware installation

Pulsar 17/TRP80/DSPR Assembly instructions

Pulsar

Pulsar 17/TRP80/DSPR Assembly instructions

MSI MPG SEKIRA 500X quick start guide

MSI

MSI MPG SEKIRA 500X quick start guide

Antec Dark fleet DF-10 user manual

Antec

Antec Dark fleet DF-10 user manual

Peavey DS 1502 Specifications

Peavey

Peavey DS 1502 Specifications

D-Link ShareCenter Pro DNS-1550-04 user manual

D-Link

D-Link ShareCenter Pro DNS-1550-04 user manual

Rosewill RX82-U(JBOD) user manual

Rosewill

Rosewill RX82-U(JBOD) user manual

QNAP SAS JBOD CLI 1.0 user guide

QNAP

QNAP SAS JBOD CLI 1.0 user guide

GAMDIAS Talos P1 Quick installation guide

GAMDIAS

GAMDIAS Talos P1 Quick installation guide

Auvs KR615 user manual

Auvs

Auvs KR615 user manual

Antec AR300 user manual

Antec

Antec AR300 user manual

CommScope FDH 3000 user manual

CommScope

CommScope FDH 3000 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Installation Sheet
RDA-ENC8W 8-Module In-Wall Enclosure
The RDA-ENC8W enclosure provides secure mounting for all AMX
Lighting, PROlink controllers, and lighting modules. This in-wall enclosure
mounts between 16" centered studs and provides eight spaces for Radia
cards, Modules, and Integrated Dimming Modules.
Install only UL approved models (see the UL Number Cross Reference to
AMX Lighting ID table on page 2) except RDM-INC and RDm-INC50.
The unit supports up to 24 dimming channels per unit. This enclosure is UL
and C-UL approved.
Installation Instructions:
• For indoor use only.
• Mount on vertical surface only.
• Maintain 16" (406.40 mm) minimum clearance above and below the
enclosure.
• Route class 1 conductors through upper conduit knockouts.
• Route class 2 conductors through lower conduit knockouts.
• Use 75°C (167°F) copper conductors only.
• Supports up to 24 dimming channels per unit (4 RDD-DM6).
• Install filler plate #28-10500 (RDA-EFP) in all unused openings.
• Install only UL approved modules (see the UL Number Cross Refer-
ence to AMX Lighting ID table on page 2) except RDM-2INC and
RDM-INC50.
• Instals within 16" (406.40 mm) centered studs or surface mount.
• Inserts 3.25" (85.09 mm) into wall to hide conduit (Knockouts
included).
• Projects 4.25" (107.95 mm) away from wall for ventillation.
Enclosure Weight:
• RDA-ENC8W: 16.5 lbs. (7.48 kg)
Dimensions between center lines (from FIG. 2):
RDA-ENC8W:
• A to B = 15.25" (387.35 mm) - Surface mounting
• C to D = 6.00" (152.40 mm) - Stud mounting
• E to F = 32.5" (825.50 mm) - Surface mounting
• G to H = 28.00" (711.20 mm) - Stud mounting
Radia enclosures must be mounted on a vertical surface with a minimum of
12" (304.8 mm) clearance above and below the enclosure.
FIG. 1 Top, bottom and front views of the RDA-ENC8W enclosure
SIDE VIEW
SIDE VIEW
SIDE VIEW
37.3"
(947.4 mm)
(365.00 mm)
7.5"
(190.5 mm)
Top, side, and bottom
views are the same for
this enclosure.
14.37"
3.25"
(82.55 mm) - located within the wall
2.25"
(57.15 mm)
(387.35 mm)
15.25"
(with case cover)
BOTTOM VIEW
(without case cover)
Metallic stud
mounting flap
BOTTOM VIEW
(with case cover)
32.5"
(825.5 mm)
FIG. 2 Bracket configuration
A to B
E to F
Bottom slot
Top slot
Configuration for
right and left
mounting brackets
for all Radia
enclosures.
Maximum mounting
screw size: #12
C to D C to D
G to H
AMX Corporation reserves the right to alter specifications without notice at any time.
For full warranty information, refer to the AMX Instruction Manual(s) associated with your Product(s).
043-019-2573 12/01 ©2001 AMX Corporation. All rights reserved.
The AMX logo is a trademark of AMX Corporation. AMX Corporation reserves the right to alter specifications without notice at any time.
3000 research drive, richardson, TX 75082 USA • 469.624.8000 • 800.222.0193 • fax 469.624.7153 • technical support 800.932.6993
The following section provides a cross reference between the UL ID
module numbers and AMX Lighting module IDs. The modules identified
are the only modules that can be used in the RDA-ENC8W enclosure.
UL Number Cross Reference to AMX Lighting ID
UL ID AMX ID UL ID AMX ID UL ID AMX ID
28-10100 RDC-DC/120 28-10200 RDM-INC 28-10300 RDM-MR60
28-10110 RDC-DC/240 28-10230 RDM-ZC,
RDM-2ZC,
RDM-PR,
RDM-2PR
28-10310 RDM-MDM
28-10120 RDC-DC/277 28-10240 RDM-ZC50 28-10340 RDA-CHK
28-10130 RDC-PDC/
120
28-10260 RDM-SWM,
RDM-2SWM,
RDM-3SWM
28-10350 RDM-FDB
RDM-2FDB
RDM-3FDB
RDM-HFDB
28-10133 RDC-PDC/
240
28-10270 RDM-HSW,
RDM-2HSW,
RDM-3HSW
28-10360 RDM-DPSM
28-10140 RDD-DM6/
120
28-10280 RDM-MR,
RDM-2MR,
RDM-3MR
28-10370 RDM-DC,
RDM-2DC,
RDM-3DC
RDM-HDC
28-10150 RDD-DM6/
240
28-10290 RDM-MR35
28-10160 RDD-DM6/
277
28-10170 RDA-PSM/120
RDA-ENC8W