Amyuni Water Systems
WMS-6 Outdoor Water Management System
TYPES OF INPUTS AND OUTPUTS
12-27V~ - POWER INPUT: This is the power supply input to the device and also powers the 3 or 6
electronic relay outputs depending on the model. The range of inputs is from 12 VAC to 27 VAC.
Although the device can be powered with DC voltage in the same range as the AC voltage, the
electronic relay outputs are not functional in this case. Only the switch inputs and mechanical relay
outputs are usable with DC power input.
PROBE: This input/output connector is used to connect external sensors to the WMS devices.
Currently two probe models are available: A submersible water level probe and a water pressure
probe as described on our web site: https://wms.amyuni.com/en/accessories.
I1, I2, I3 -INPUT SWITCHES: These are used to connect external switches to the WMS devices.
The behaviour is programmable with the accompanying software. Examples of switches are:
Simple On/Off switches which can be used to manually disable certain functions
Float switches that open or close when water level reaches a certain level
Pressure switches that activate when water pressure reaches certain thresholds
O1 TO O6 -ELECTRONIC RELAY OUTPUTS: Used to connect AC voltage powered devices. The
voltage of devices connected to these outputs is the same as the voltage used to power the WMS
device. The power used by all devices that are turned on at the same time should also not exceed
the power supply of the device. If the default 24V/60Watt transformer is used, the total number of
devices on at the same time should not exceed 60 Watts or about 2.5 Amperes. Examples of AC
devices:
Electric valves used in irrigation systems
Garden lights working on low AC voltage
Electric water valves