ATIQ46H/79PRChlorine Manual TableOf Contents
3
O&M Manual
Rev-E(5/17)
Table of Contents
PART1- INTRODUCTION................................. 5
1.1 General...................................................... 5
1.2 Standard System....................................... 5
1.3 Features..................................................... 9
1.4 Q46H/79PRSystemSpecifications.........11
1.5 Q46H-79PRPerformance Specifications.13
PART2–ANALYZERMOUNTING.................14
2.1 General.....................................................14
2.2 Wall or PipeMount..................................15
2.3 Panel Mounting........................................17
PART3–SENSOR/FLOWCELLMOUNTING18
3.1 General.....................................................18
3.2 Constant-HeadFlowcell...........................18
3.3 SealedFlowcell........................................19
3.4 SubmersionMounting..............................21
PART4–ELECTRICALINSTALLATION......22
4.1 General.....................................................22
4.2 Power Connection....................................23
4.3 Direct Sensor Connection ........................27
4.4 Sensor Wiring ..........................................28
4.5 JunctionBoxConnection.........................29
4.6 Optional pHSensor Input........................30
PART5–SENSORASSEMBLY.........................31
5.1 ChlorineSensor Preparation....................31
5.2 Optional pHSensor..................................33
PART6–CONFIGURATION.............................34
6.1 User Interface...........................................34
6.11 Keys.........................................................35
6.12 Display.....................................................35
6.2 Software...................................................37
6.21 SoftwareNavigation...............................37
6.22 MeasureMenu [MEASURE]...................40
6.23 CalibrationMenu [CAL].............................41
6.24 ConfigurationMenu[CONFIG]..............42
6.25 ControlMenu[CONTROL]....................48
6.26 DiagnosticsMenu[DIAG].........................54
PART7–CALIBRATION...................................59
7.1 ChlorineCalibration.................................59
7.11 ChlorineZero Cal....................................59
7.12 ChlorineSpanCal....................................60
7.2 TemperatureCalibration ..........................62
7.3 pHCalibration..........................................63
7.31 Two-PointpHCal....................................64
7.32 One-PointpHCal.....................................65
PART8–PIDCONTROLLERDETAILS.........66
8.1 PIDDescription.......................................66
8.2 PIDAlgorithm.........................................66
8.3 Classical PIDTuning ...............................68
8.4 ManualPIDOverrideControl..................69
8.5 CommonPIDPitfalls...............................69
PART9–SYSTEMMAINTENANCE................71
9.1 General.....................................................71
9.2 Analyzer Maintenance.............................71
9.3 Sensor Maintenance.................................71
9.4 Sensor AcidCleaning..............................72
9.5 Q22PSensor Cleaning.............................73
9.6 ReplacingtheSaltbridgeandReference
Buffer Solution..........................................74
9.7 FlowCell Maintenance............................75
PART10 –TROUBLESHOOTING....................76
10.1 General.....................................................76
10.2 External SourcesofProblems..................76
10.3 Analyzer Tests.........................................78
10.4 DisplayMessages....................................79
10.5 Sensor Tests.............................................81
10.6 Troubleshooting(Q22PSensor)...............83
SPAREPARTS......................................................84