Bluetooth!4.0!Pulse!Oximeter!!ADF-B06!
FCC!Statement!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!! !
This!device!complies!with!Part!15!of!the!FCC!Rules.!Operation!is!subject!
to!the!following!two!conditions!:!!
(1)!this!device!may!not!cause!harmful!interference.!
(2)!this!device!must!accept!any!interference!received,!including!interference!that!!
may!cause!undesired!operation.!
NOTE:!!This!equipment!has!been!tested!and!found!to!comply!with!the!limits!!
for!a!Class!B!digital!device,!pursuant!to!Part!15!of!the!FCC!Rules.!!These!limits!!
are!designed!to!provide!reasonable!protection!against!harmful!interference!in!
a!residential!installation.!!This!equipment!generates,!uses!! and!can!radiate!!
radio!frequency!energy!and,!if!not!installed!and!used!in!accordance!! !
with!the!instructions,!may!cause!harmful!interference!to!
radio!communications.!
However,!there!is!no!guarantee!that!interference!will!not!occur!in!a!particular!!
installation.!!If!this!equipment!does!cause!harmful!interference!to!radio!or!!
television!reception,!which!can!be!determined!by!turning!the!equipment!off!!
and!on,!the!ser!is!encouraged!to!try!to!correct!the!interference!by!one!or!more!
of!the!following!measures:!
●!Reorient!or!relocate!the!receiving!antenna.!
●!Increase!the!separation!between!the!equipment!and!receiver.!
●Connect!the!equipment!into!an!outlet!on!a!circuit!different!from!that!to!!
which!the!receiver!is!connected.!
●Consult!the!dealer!or!an!experienced!radio/TV!technician!for!help.!
Warning:!!Changes!or!modifications!to!this!unit!not!expressly!approved!by!! the!!
party!responsible!for!compliance!could!void!the!user’s!authority!to!operate!
the!equipment.!
!
!Precautions!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
l!Do!not!attempt!to!maintain!the!Oximeter!unless!you!are!professional!
engineers.!Only!professionals!with!maintenance!qualification!are!allowed!
to!perform!interior!maintenance!as!necessary.!
l!Periodically!change!the!contact!position!between!the!Oximeter!probe!
and!the!finger!for!a!measurement!that!lasts!a!long!time.!Adjust!the!
position!of!the!probe!before!the!measurement!lasts!two!hours,!and!
check!the!integrity!of!skin,!the!blood!circulation!condition!of!the!finger!as!
well!as!the!position!of!the!finger.!
l!This!product!is!not!applicable!to!the!examination!of!newborn!babies.!
l!Seek!for!medical!care!in!time!if!the!measured!value!goes!beyond!the!
normal!range!while!you!are!sure!that!the!instrument!does!not!
malfunction.!
l!Do!not!directly!expose!your!eyes!to!light-emitting!components!of!the!
Oximeter,!as!that!could!cause!harm!to!your!eyes.!
l!For!details!about!clinical!limitations!and!contraindications,!please!
carefully!consult!relevant!medical!literatures.!
The! following! factors! may! cause! disturbance! to! or! affect! the! accuracy! of!
examination:!
◆!This!product!is!used!in!an!environment!involving!high-frequency!devices,!
such!as!high-frequency!electric!knives!and!CT!apparatuses.!
◆!The!probe!of!the!Oximeter!is!placed!on!the!same!body!part!or!limb!as!
with!blood!pressure!cuff!arterial!duct!or!intravenous!injection.!
◆!The!user!suffers!from!hypotension,!severe!vascular!atrophy,!severe!
anemia,!or!low!oxygen.!
◆!The!user!is!in!sudden!cardiac!arrest!or!shock!state.!
◆!The!finger!with!nail!polish!or!a!fake!fingernail!may!cause!wrong!readings!
of!pulse!oxygen!saturation.!
!
Warnings!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
Warning:!Do!not!use!the!Oximeter!in!an!environment!with!any!inflammable!gases,!
inflammable!anesthetic,!or!other!inflammable!substances.!
Warning:!Do!not!attempt!to!charge!any!common!dry!battery,!as!that!could!cause!
leakage,!fire!disaster,!or!even!explosion.!Dispose!of!exhausted!batteries!in!
accordance!with!environment!protection!regulations.!
Warning:!Do!not!use!the!Oximeter!in!an!MRI!or!CT!environment.!
Warning:Do!not!operate!the!Oximeter!when!it!is!damp!with!overflow!or!water!
vapor!condensation.!Avoid!moving!the!Oximeter!from!an!excessively-cold!
environment!to!a!high-temperature!moist!environment.!
!
!
!
Symbol!Conventions!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
Symbol!
Description!
!
BF-type!application!part!
!
Caution:!Please!see!this!manual.!
%SpO2!
Symbol!of!oxygen!saturation!
bpmPR!
Symbol!of!pulse!rate!
!
Bluetooth!symbol!
!
When! end! users! abandon! this! product,! they!
must! send! the! product! to! the! collection! place!
for!recycling.!
!
Overview!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
Oxygen!saturation!is!the!percentage!of!oxyhemoglobin!(HbO2)!that!is!combined!
with!oxygen!against!all!combinable!hemoglobin!(Hb).!It!is!an!important!
physiological!parameter!involved!in!respiration!and!circulation.!The!oxygen!
saturation!of!arterial!blood!in!a!normal!human!body!is!98%.!Oxygen!saturation!is!an!
important!indicator!of!the!oxygen!condition!in!the!human!body.!In!general,!the!
normal!values!of!oxygen!saturation!shall!not!be!lower!than!94%.!If!the!measured!
value!of!oxygen!saturation!is!lower!than!94%,!an!insufficient!supply!of!oxygen!is!
considered.!
The!pulse!rate!is!the!number!of!pulse!beats!per!minute.!Normally,!the!pulse!rate!is!
consistent!with!the!heart!rate.!In!general,!the!pulse!rate!of!every!people!is!60!to!90!
beats!per!minute.! !
The!Perfusion!Index!(PI)!usually!reflects!the!limb!perfusion!status!of!an!examined!
patient,!and!shows!the!detection!precision!of!the!instrument!as!well;!that!is,!
examination!can!still!be!performed!even!in!the!low!or!weak!perfusion!condition.The!
PI!of!a!normal!human!body!is!3%!or!greater.!
!
Working!Principles,!Expected!Usage,!and!Applicable!Scope!!!!!!!!!!
Based!on!full!digital!technology,!the!Finger!Pulse!Oximeter!non-invasively!measures!
the!actual!content!(oxygen!saturation)!of!oxyhemoglobin!(HbO2)!in!arterial!blood!
using!the!optical!transmittance!method.! !
The!Finger!Pulse!Oximeter!measures!the!blood!oxygen!saturation!and!pulse!rate!of!
a!human!body!via!finger!artery.!It!is!applicable!to!a!wide!range!of!fields,!such!as!
families,!hospitals!(including!operation!rooms!of!the!departments!of!internal!
medicine!and!surgery,!the!department!of!anesthesiology,!the!department!of!
paediatrics,!and!intensive!care!rooms),!oxygen!bars,!social!medical!care!institutions,!
and!sports!&!health.!Use!this!instrument!for!measurement!before!or!after!sports.!
You!are!not!advised!to!use!this!instrument!during!sports!activities.!It!is!applicable!to!
patients!15!to!60!years!old.!Do!not!use!it!for!continuous!care!for!patients.!
!
Schematic!Diagram!of!Display!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
The! following! figure! shows! the! information! display! on! the! OLED! screen! of! the!
Oximeter!in!normal!detection!state:!!!!!!!!!!!!!!!!!!!!!!!
!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
!Symbol!of!oxygen! ! !
saturation!
!Measured!value!of!
oxygen!saturation!
!Bar!graph!
!Plethysmogram!
!Measured!value!of! !
!!!!Pulse!rate!
!PI!
!Symbol!of!pulse!rate!
!Battery!power!indication/Bluetooth!symbol!(alternately!displayed)!
!
Power-On!Key/Functional!Key!Operations!!!!!!!!!!!!!!!!!!!!!!!!
After!powering!on!the!Oximeter,!hold!the!power-on!key/functional!key!for!about!
one!second.!The!Oximeter!shows!a!parameter!setting!interface.!Press!or!hold!the!
power-on/functional!key!to!perform!corresponding!operations.!Hold!it!to!set!an!
item,!or!press!it!to!switch!an!option!or!switch!the!display!mode.!Press!means!no!
more!than!0.5!seconds,!while!Hold!means!more!than!0.5!seconds.!
!
Alert!Sound!Setting!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
Hold!the!power-on!key/functional!key!while!the!Oximeter!is!in!powered-on!state.!
Parameter!setting!interface!1!is!displayed,!as!shown!in!the!following!figure.!Move!
"*"!to!the!corresponding!option,!and!hold!the!functional!key!to!set!Alm!to!on!and!
set!Beep!to!off.!When!Alm!is!set!to!on!and!the!measured!values!of!the!blood!
oxygen!saturation!and!pulse!rate!go!beyond!the!upper!limit!or!lower!limit,!the!
Oximeter!gives!off!an!alert!sound.!When!Alm!is!set!to!off!and!the!measured!values!
go!beyond!the!limit,!the!Oximeter!will!not!give!any!alert!sound.!When!Beep!is!set!to!
on,!a!tick!will!be!heard!along!with!pulse!beats!during!pulse!rate!measurement.!
When!Beep!is!set!to!off,!no!sound!will!be!output!along!with!pulse!beats!during!
pulse!rate!measurement.!While!the!"*"!symbol!stays!on!the!Restore!option,!hold!
the!functional!key!to!restore!factory!settings.! !
!
Brightness!Setting!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
On!parameter!interface!1,!press!the!functional!key!to!select!the!Brightness!option!
and!then!hold!the!functional!key!to!set!the!brightness!to!a!value!ranging!from!1!to!5.!
The!greater!the!value,!the!greater!the!brightness!of!the!screen.! !
Power!saving!function!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
The!ADF-B06!has!a!power!saving!feature.!It!can!save!power!through!reducing!
screen!brightness!automatically.!During!measurement!the!brightness!will!reduce!to!
level!1!automatically!after!150!seconds!without!pressing!the!function!key,!to!make!
it!recover!to!original!brightness!please!press!the!function!key.!
Alert!Range!Setting!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
On!parameter!interface!2,!press!the!functional!key!to!switch!between!options.!On!
this!interface,!you!can!set!the!upper!limit!and!lower!limit!of!SpO2!Alm!and!PR!Alm.!
While!the!"*"!symbol!stays!on!the!+/-!option,!hold!the!functional!key!to!set!the!
option!to!+!or!-.!In!+!mode,!select!the!corresponding!option!and!hold!the!functional!
key!to!increment!the!upper!or!lower!limit;!in!-!mode,!hold!the!functional!key!to!
decrement!the!upper!or!lower!limit.!Move!"*"!to!the!Exit!option,!and!hold!the!
functional!key!to!return!to!the!monitoring!interface.!
!
!!!!!!!!!!!!
Operation!Guide!
Switch!on!the!power!supply!of!the!pulse!Oximeter!
Stick!one!finger!completely!into!the!rubber!pad!cavity!of!the!Oximeter,!keep!the!
fingernail!surface!upward,!and!release!the!clip.!Then!press!the!power!key!to!power!
on!the!Oximeter.!
If!you!do!not!yet!completely!insert!
your!finger!into!the!cavity,!the!
measurement!result!may!be!
inaccurate.!
Do!not!vibrate!your!finger!during!
measurement.!Preferably,!ensure!
that!your!body!does!not!move.!After!
the!readings!become!stable,!read!
the!measured!values!of!
oxygen!saturation!and!the!
pulse!rate!on!the!screen.!
The!Oximeter!will!automatically!shut!down!10!seconds!later!after!your!finger!leaves!
away.!
Connect!device!via!Bluetooth!4.0!
Prior!to!first!use,!download!and!install!"Andesfit"!application!to!your!device.!
(Bluetooth!4.0!capabilities)!For!details,!see!quick!start!guide!for!the!phone!/!tablet.!
About!the!Display!
Continuously!press!the!functional!key!in!the!monitoring!process.!The!monitored!
data!and!the!display!mode!will!be!cyclically!displayed!on!the!OLED!screen!in!two!
different!ways!(large!fonts!and!plethysmogram)!and!four!directions,!as!shown!in!
the!following!figure.!
Replace!the!batteries!when!the!battery!capacity!is!insufficient!and!the!symbol!
!flickers!on!the!screen.!
Cleaning!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
Power!off! !the!instrument!and!remove!the!batteries!before!cleaning.!Ensure!that!
the!appearance!of!the!instrument!is!neat,!dust-free,!and!dirt-free.!Clean!the!outer!
surface!of!the!instrument!(including!the!OLED!screen)!using!75%!medical!alcohol!
and!a!piece!of!dry!soft!cloth.!
Caution:!Avoid!liquid!flowing!into!the!instrument!during!cleaning.!
Caution:!Do!not!immerse!any!part!of!the!instrument!into!any!liquid.!
Disinfection!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
Before!measurement!with!the!instrument,!wipe!the!rubber!finger!pad!using!a!piece!
of!dry!soft!cloth!dipped!with!75%!medical!alcohol.!Clean!the!finger!to!be!measured!
using!the!medical!alcohol!for!disinfection!purposes!before!and!after!use.! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! !
Maintenance!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
lRemove!the!batteries!from!the!battery!slot!and!properly!store!them!if!you!do!
not!plan!to!use!the!Oximeter!for!a!long!period!of!time.!
lStore!the!Oximeter!between!14!and!122°F!(–10!to!+50°C)!and!at!humidity!
levels!no!greater!than!93%.!
lPeriodically!check!the!Oximeter!for!damage.!
lAvoid!using!the!Oximeter!in!an!environment!with!inflammable!gases!or!using!it!
in!an!environment!where!the!temperature!or!humidity!is!excessively!high!or!
low.!
lCheck!the!accuracy!of!the!oxygen!saturation!and!pulse!rate!readings!by!using!
an!appropriate!calibration!apparatus.!
Technical!Specifications!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
1.!Dimensions:!62.0!mm!(Width)!×!37.0!mm!(Depth)!×!32.0!mm!(Height)!
Weight:!42.5!g!(including!the!height!of!the!two!AAA!dry!batteries)!
2.!Peak!wavelength!range!of!the!light!emitted!from!the!probe:!red!light!660!nm!±!
3;!infrared!light!905!nm!±!5.!
3.!Maximum!optical!output!power!of!the!probe:!1.2!mW!for!infrared!light!(905!
nm).!
4.! !Bluetooth!module:!4.0!(single-mode)!
5.!Normal!working!condition!
Working!Temperature!
5°C!to!40°C!(41°F!to!104°F)!
Relative!Humidity!
15%!to!80%,!non-condensing!
Atmospheric!Pressure!
70!kPa!to!106!kPa!
Rated!Voltage!
DC!3.0!V!
6.!Default!values!and!conditions!of!alert!
Parameter!
Value!
Oxygen!saturation!
Upper!limit:!100!
Lower!limit:!94!
Pulse!rate!
Upper!limit:!130!
Lower!limit:!50!
Alert!condition!
When!the!alert!switch!is!on!and!the!
actual!measured!value!goes!beyond!the!
preset!alert!parameter!range,!the!
Oximeter!gives!an!alert!sound.!
7.!Technical!parameters!
Parameter!
Value!
Display!range!
Oxygen!
saturation!
35%!to!100%!
Pulse!rate!
25!bpm!to!250!bpm!
Resolution!
Oxygen!
saturation!
1%!
Pulse!rate!
1!bpm!
Measurement!
precision!
Oxygen!
saturation!
±2%!(70%!to!100%)!
No!requirement!(≤!69%)!
Pulse!rate!
±2!bpm!
Alert!range!
Oxygen!
saturation!
Upper!limit:!50%!to!100%!
Lower!limit:!50%!to!100%!
Pulse!rate!
Upper!limit:!25!bpm!to!250!bpm!
Lower!limit:!25!bpm!to!250!bpm!
Alert!error!
Oxygen!
saturation!
±!1%!of!the!preset!value!
Pulse!rate!
The!greater!of!±10%!of!the!preset!
value!and!±5!bpm!
PI!
Weak!PI!
Min.!0.2%!
Safety!Type!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
Anti-electric-shock!type:!internal!power!supply!device!
Anti-electric-shock!degree:!BF-type!application!part!
Waterproof!grade:!IP22!
Storage!and!Transportation!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
Packaged!products!should!be!stored!in!well-ventilated!rooms!without!
corrosive!gas!and!with!an!ambient!temperature!of!–10!to!+50°C,!a!relative!
humidity!lower!than!93%!(without!condensation),!and!an!atmospheric!
pressure!of!50–106!kPa.!
!Wellkang!Ltd! !
!Suite!B,!29Harley!Street,!LONDON,!W1G9QR,U.K.! !

Popular Medical Equipment manuals by other brands

gbo Medizintechnik ULTRATHERM 1008 Instructions for use

gbo Medizintechnik

gbo Medizintechnik ULTRATHERM 1008 Instructions for use

3A HEALTH CARE MINIASPEED Battery Evo Plus instruction manual

3A HEALTH CARE

3A HEALTH CARE MINIASPEED Battery Evo Plus instruction manual

Nasco CRiSis LF03616U instruction manual

Nasco

Nasco CRiSis LF03616U instruction manual

EZee Life CRP0030 Assembly instructions

EZee Life

EZee Life CRP0030 Assembly instructions

Bayer HealthCare Rapidlab 800 Operator's manual

Bayer HealthCare

Bayer HealthCare Rapidlab 800 Operator's manual

Pari MONTESOL Instructions for use

Pari

Pari MONTESOL Instructions for use

DeRoyal Solace 13400005 Instructions for use

DeRoyal

DeRoyal Solace 13400005 Instructions for use

Otto Bock Walker Boot Instructions for use

Otto Bock

Otto Bock Walker Boot Instructions for use

DJO CMF Patient guide

DJO

DJO CMF Patient guide

Arjo AtmosAir Velaris Quick reference guide

Arjo

Arjo AtmosAir Velaris Quick reference guide

dispomed ModuFlex NRB manual

dispomed

dispomed ModuFlex NRB manual

Stryker Adel Maternity Bed Series Operation manual

Stryker

Stryker Adel Maternity Bed Series Operation manual

A2J Pelvi.loc PL-3DB Assembly instruction and manual

A2J

A2J Pelvi.loc PL-3DB Assembly instruction and manual

InTouch Health Vantage Quick reference guide

InTouch Health

InTouch Health Vantage Quick reference guide

Abbott CentriMag Reference manual

Abbott

Abbott CentriMag Reference manual

Atos Medical Provox LaryTube manual

Atos Medical

Atos Medical Provox LaryTube manual

laerdal HEARTSTART quick start guide

laerdal

laerdal HEARTSTART quick start guide

EMS Swiss Master Light Operation instructions

EMS

EMS Swiss Master Light Operation instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.