TROUBLESHOOTING
Always disconnect the pump from the power supply before handling.
If the pump, nozzles or optional water feature fail to operate:
•Check to make sure the power cord is plugged in and the receptacle has
power running to it.
•Check to ensure pump is fully submersed in water.
•Check the tubing for kinks or obstructions, and pump outlet is clear of objects.
•Check if water features or fountain nozzles are clean and clear.
•Check the spray nozzles for obstructions or a loose connection
•Check water inlet for any obstructions.
If water flow has not returned:
•Remove front cover and impeller cover to access rotor area.
•Rotate the rotor to ensure it is not broken or jammed. Remove the
rotor to check it is free from any debris.
•Rinse the cover and re-assemble.
LIMITED WARRANTY
These components are warranted to the original user against defective materials and
workmanship for a period of 12 months. Our limited warranty does not cover any costs
associated with the installation or removal of products subject to warranty claims or the cost
of return. The warrantywill commence from the date of purchase. Replacement liability is
limited to anypart or parts of the unit which have failed due to defective material or
workmanship. Proof of purchase is required for all claims against the limited warranty. This
warranty does not extend to damage of the product or part resulting from accident, misuse,
alteration, neglect, abuse, improper installation or normal wear and tear to the product(s).
This limited warrantyextends only to the original user of the product.
Pump and Nozzle Kit Instructions
THANK YOU FOR BUYING A POND BUILDING SERIES™ PRODUCT.
PACKAGE CONTENTS
01. Tiered Spray Nozzle
02. Bell Spray Nozzle Head
03. Trumpet Spray Nozzle Head
04. Bell and Trumpet Nozzle Base
05. Connector
06. Telescoping Riser
07. Pump Output
08. Diverter
09. Pump with Pre-Filter
IMPORTANT! - BEFORE YOU BEGIN
This pump is designed for use in “clean water applications”, if you are using ONLY the
integrated pre-filter cartridge. It is not compatible with salt water.
Using this series of pump in an outdoor functional pond environment without using proper
filtration will cause increased maintenance and could result in pump failure due to a
build-up of debris. This type of improper pump care is not covered under warranty.
We strongly recommend the use of a filter box for use
in any pond application.
Pond Filter Box 600 using
The Included Pump Pre-filter Diverter and Trumpet Nozzle
provides basic filtration, however this
filter box should be used with any pond
application that includes fish and plants.
QUESTIONS?
PLEASE DO NOT RETURN THIS ITEM TO THE STORE.
Please visit our website www.angelodecor.com for more information
and videos on how to assemble and properly use your product.
For more information on this and other products, please visit our web site:
www.angelodecor.com
PLEASE DO NOT RETURN THIS UNIT TO THE STORE.
To contact us regarding this unit, your options include:
Email:customersupport@angelodecor.com | Phone: (780) 453 - 6646 | Fax: (780) 453- 6620
Angelo Décor International Inc. | 15840 – 118th Avenue | Edmonton, AB |T5V 1C4
01
08
02 03
09
04
05
07
Diagram #1
06
Diagram # 2
AD40100 / AD40200
WARNING: SAFETY AND ELECTRICAL CONNECTIONS
The pump is supplied with 10 feet of 3 core electrical cable, permanently connected and sealed
to the motor. The cable cannot be replaced. Pump should be discarded if cord is damaged.
•Pump must be connected to an approved ground fault circuit interrupter
•Warning:
(GFCI)
receptacle. Do not connect to anyvoltage other than that stated on the pump.
Always
•Do not use the supplycable to lift the pump as this may cause damage.
unplug or disconnect from the electricity supply before putting
hands in the water, while equipment is being handled in any way.
•Do not operate or leave the pump in freezing conditions.
•Do not allow the pump to run dry. The pump must be fully submerged.
PRE-ASSEMBLY PREPARATIONS
•Identify the height of riser and / or other elevation required to feature the
nozzle at the desired level in your pond.
•Assess the parts required from diagram #1, to determine what you will need
to properly mount the chosen assembly to your pump.
•See the outer packaging of this product for performance details on the
included fountain nozzles. These four popular spray patterns provide you
visual and functional options that suit most pond sizes and environments.
ASSEMBLY INSTRUCTIONS
Single Feature use
1. Attach the connector
to the base pump output
2. Attach Telescoping Riser Tube, and your Fountain Nozzle choice.
Dual Feature use (AD40200 ONLY)
Fountain Nozzle with Spouting Statue (sold separate)
1. Insert Diverter into base pump output
2. Attach the connector
3. Attach Telescoping Riser Tube, and your
choice of fountain nozzle
4. Use 1/2” ID Tubing (not supplied) to attach to your water feature.
Fountain Nozzle Head Assembly:
•Spray nozzle heads should be
assembled and connected as
shown in Diagram # 5.
Please Note: Trumpet and Bell Nozzle
share the same base unit. The feature
piece is threaded into the base to allow
adjustment of the water spray diameter.
INSTALLATION IN POND
•Place pump on top of a flat brick or stone approximately 2” from bottom of
pond to help prevent debris from interfering with the pump’s performance.
•Make sure the cable is securely routed to the GFCI electrical supply and is
protected against abrasion and damage.
CARE AND MAINTENANCE
Before cleaning, always disconnect the pump from the power supply and
remove from pond.
•Do not pump heated liquids. Unit is tested for fresh water use only.
•Pond water must be kept clean using proper filtration components.
•Always operate the pump completely submerged.
•Disassemble the unit periodically to clean mineral deposits and build up of
debris inside the impeller and rotor.
•Clean components when visibly soiled or a drop in performance is noted.
•Use a cloth or soft brush with warm soapy water when cleaning.
•Do not operate this pump below 0oC, as FREEZING DAMAGE MAY OCCUR.
Diagram # 3
Diagram # 5
Diagram # 6
Note: For item AD40100, we recommend using the diverter for flow control
purposes ONLY.
Diagram # 4

This manual suits for next models

2

Other Angelo Decor Pond Pump manuals

Angelo Decor Pond Building AD40401 User manual

Angelo Decor

Angelo Decor Pond Building AD40401 User manual

Angelo Decor Pond Building Series User manual

Angelo Decor

Angelo Decor Pond Building Series User manual

Angelo Decor Pond Building AD40251 User manual

Angelo Decor

Angelo Decor Pond Building AD40251 User manual

Popular Pond Pump manuals by other brands

Fiap profifeed SolarFeeder operating instructions

Fiap

Fiap profifeed SolarFeeder operating instructions

AQUA FORTE Prime UV 75W Instructions for use

AQUA FORTE

AQUA FORTE Prime UV 75W Instructions for use

EasyPro PA90AD Installation, Operation, Maintenance Guidelines

EasyPro

EasyPro PA90AD Installation, Operation, Maintenance Guidelines

AquaScape EXT 12000 Instructions & maintenance

AquaScape

AquaScape EXT 12000 Instructions & maintenance

Evolution Aqua Varipump 10000 instruction manual

Evolution Aqua

Evolution Aqua Varipump 10000 instruction manual

Messner system-N 850 operating instructions

Messner

Messner system-N 850 operating instructions

Danner Pondmaster 1250 Care and operating instructions

Danner

Danner Pondmaster 1250 Care and operating instructions

EasyPro ETP05 Instructions for Operation, Safety, Warranty

EasyPro

EasyPro ETP05 Instructions for Operation, Safety, Warranty

Messner e-finity Q-Tec 25 operating instructions

Messner

Messner e-finity Q-Tec 25 operating instructions

T.I.P. WPS 1000 R operating instructions

T.I.P.

T.I.P. WPS 1000 R operating instructions

Waldbeck Lagoon 3000 manual

Waldbeck

Waldbeck Lagoon 3000 manual

Oase AquaMax Eco Classic Series operating instructions

Oase

Oase AquaMax Eco Classic Series operating instructions

Hozelock Cyprio Aquaforce Series Installation and operating instructions

Hozelock Cyprio

Hozelock Cyprio Aquaforce Series Installation and operating instructions

Meßner eco-N 850 operating instructions

Meßner

Meßner eco-N 850 operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.