ANthony 101 User manual

03/13/2019 IN-0031_G 1 OF 8
Anthony Smart Controller
Installation Instruction
(For All 101, 401, 1001 Model Frames)
IN - 0031

03/13/2019 IN-0031_G 2 OF 8
The purpose of this document is to provide a guide for
easier installation of the Anthony Smart Controller
Table of Contents
1. Features and Updates
2. Controller Unit Installation
3. Sensor Board and Plastic Housing Installation
4. Standard Frame and Sensor Preparation
5. Wiring Schematic
6. Adjustment Settings
7. Specifications
8. Revision History
WARNING: TO REDUCE THE RISK OF FIRE,
ELECTRICAL SHOCK OR INJURY, OBSERVE
THE FOLLOWING:
1) Use this unit in the manner intended by the
manufacturer.
2) Switch power off before servicing or cleaning.
BEFORE YOU BEGIN
Read instructions completely and carefully.
Anthony Smart Controller
Installation Instruction for All 101
,
401
,
1001 Model

03/13/2019 IN-0031_G 3 OF 8
1.Features and Updates
1. Features
a. Controller units and sensor Plug and Play
b. Adjustability for Controller
2. Updates
a. Connection improvements have been made for
Serviceability (Plug and Play connectors)

03/13/2019 IN-0031_G 4 OF 8
2.Controller Unit Installation for 101
Note Connection improvements have been made for Serviceability (Plug and Play connectors )
See Steps A - K
Mount the smart controller unit on the first center mullion on the right
from customer side using self tapping screws. As shown above.
Remove sealing plate by inserting a flat
screwdriver under the retaining strip starting
at the top as illustrated.
Locate the AI
SMART
CONTROLLER
Unit location
**VISTA DOORS ONLY – IF SMART CONTROLLER
DOES NOT FIT INSIDE MULLION. THE TECHNICIAN
MUST INSTALL THE SMART CONTROLLER UNIT
REMOTELY OUTSIDE THE FRAME.
**BEFORE MOUNTING SENSOR ON FRAME, MAKE
SURE THE HOLD OPEN ARM DOES NOT
INTERFERE WITH THE SENSOR LOCATION
**BEFORE MOUNTING SENSOR ON FRAME,
MAKE SURE THE HOLD OPEN ARM
DOES NOT INTERFERE WITH THE SENSOR
LOCATION
A
B
C

03/13/2019 IN-0031_G 5 OF 8
Mount the smart controller unit on the top of the raceway using
#8 x ¼” long thread forming screws. As shown above.
Controller Unit Installation for
401, 1001
Remove raceway cover slip by inserting a
flat screwdriver under the retaining strip
starting at the top as illustrated. Raceway
located directl
y
behind frame rail.
AI SMART
CONTROLLER
UNIT
LOCATION
RACEWAY
COVER SLIP
Remove raceway slip as needed. Remove
raceway bracket with Phillips screwdriver if
needed.
Mount the smart controller unit on the raceway, on center,
where the mullion on the right from customer side using self
tapping screws.
AI SMART
CONTROLLER
UNIT
LOCATION
E
D
F

03/13/2019 IN-0031_G 6 OF 8
3.Sensor Board and Plastic
Housing Installation
STANDARD HOUSING INSTALLATION
Align the sensor board holes with the
housing mounting holes. Connect the
gray wire connector into the sensor
board circuit as shown.
Using the Plug and Play connectors,
Make sure the gray wire is securely
fastened to the sensor board.
CABLE
CONNECTOR
Close the top cover piece into the
bottom housing piece. Be sure the
gray wire exits the back as shown in
the left
p
icture.
TOP PIECE
GRAY WIRE
When fastening the top and bottom
housing, you should hear four clicks
due to the snap on feature.
H
I
J
K

03/13/2019 IN-0031_G 7 OF 8
FRAME AND
RACEWAY
4.Standard Frame & Sensor Preparation
STEP 1
Begin wiring the smart controller following the wiring schematic on page 5.
The sensor cable must travel from the center mullion to the top of the channel
shown below .
STEP 2
Cut a ¼” X 1” rectangular cut on the
contact plate to allow for passage of the
sensor cable.
Apply a ¾” X 2 ¼” piece of seal foam with
a cut slit for wire placement on the contact
plate to prevent air intake/outtake.
Insert the sensor cable into the cutout and
replace the sealing plate to the frame.
STEP 3
Push the excess sensor cable back through
the channel, reducing the slack.
Seat the sensor (see figure for location) until
flush to the frame flange, pushing it as far
back as possible.
Using self-drilling screws, mount the sensor
housing to the inner frame of the door system.
Reinstall the sealing plates.
CUT OUT
HEATER CABLE
AND WIRES
SEAL FOAM WITH SLIT
SENSOR LOCATION: UPPER
FRAME RAIL ABOVE SECOND
DOOR FROM THE RIGHT

03/13/2019 IN-0031_G 8 OF 8
5.Wiring Schematic

03/13/2019 IN-0031_G 9 OF 8
6.Adjustment Settings
LOW HIGH
Operating Instructions:
The green light indicates when power is being
applied to the unit. The controller is pre-set for
standard operating conditions, but may be
adjusted with a potentiometer to
accommodate colder or warmer refrigerators.
Turn the potentiometer clockwise, using a
small screwdriver, to provide more heat, or
counterclockwise to provide less heat, at a

03/13/2019 IN-0031_G 10 OF 8
7.Specifications
MODEL: 60-17156-0001
INPUT VOLTAGE: 120 – 230 VOLTS
INPUT FREQUENCY 50/60 HZ
MAX. CURRENT 10 AMPS
UL CERTIFICATION NUMBER: SA33080
WIRE COLORS ARE: GRAY, WHITE/BLU, RED AND BLUE/WHITE
4 SENSOR BOARD
CIRCUIT
GRY
WHT/BLU 3 (NEUTRAL, INPUT/OUTPUT)
RED
BLU/WHT
2 (LINE OUTPUT)
1 (LINE INPUT)
HUMIDITY
CONTROLLER
4 SENSOR BOARD
CIRCUIT
GRY
WHT/BLU 3 (NEUTRAL, INPUT/OUTPUT)
RED
BLU/WHT
2 (LINE OUTPUT)
1 (LINE INPUT)
HUMIDITY
CONTROLLER

03/13/2019 IN-0031_G 11 OF 8
REV Ori
g
inato
r
Description of chan
g
e Effective Date
A
Initial release
B Reformat 7/27/2010
C Reformat 11/03/2010
D Reformat 03/15/2011
E Sam Fishe
r
Reformat 03/05/2012
F Sam Fishe
r
Reformat & new lo
g
o 05/21/2013
G KHolst
A
dd purpose & or
g
anized workflow 03/13/2019
8.Revison