AP&T AP-DC2453 User manual

Mini Ionizing Air Blower
AP-DC2453
Mini Ionizing Air Blower
AP&T
R
Shanghai Anping Static Technology Co.,Ltd
AP&T

Suitable for electronics, optoelectronics,
semiconductor and other industries
Effectively solve the problems
caused by static electricity
Static Removal Prevent uneven scattering
Control ink splashing
Prevent adhesion of objects Prevent blockage of adhesion

1 s
150mm
150mm
150mm
0mm
3 s
300mm
5 s
450mm
Keep a clean production environment and stay
away from static electricity
High Efficiency Static Removal
Discharge effect
Test standard:ANSI/ESD.STM3.1,SJ/T 11446—2013
Test instrument: Trek 157 static tester
Test voltage:±1000V → ±100V attenuation
Test environment:humidity 50±5%;temperature 23±3℃
Working way
AP-DC2453 mini ionizing air blower uses positive
and negative synchronous emission electrodes to
generate corona discharge through DC high voltage,
ionize air molecules and generate a large number of
positive and negative air ions, which are blown to the
surface of the object with electrostatic to be eliminated
by the axial fan.
DC
DC
T
Steady-state DC
+HV
(Positive high voltage)
-HV
(Negative high voltage)
Positive high voltage Negative high voltage

No.1
No.3
No.4
No.5
3 speed adjustment
A button on the back of ionizing air
blower to adjust the wind speed of
high, middle and low.
External power adapter
Configure special external power adapter.
Standard tungsten alloy
needle
Longer life time compare to titanium and
silicon materials.
Features
Safe / Easy to use / Durable
Mini type
Compact size and easy to install which can be installed
inside other equipment for static removal.
No.2
CE certification
CE certified which is a high-security and
high-reliability static eliminator.

Unit:mm
U-shaped bracket Air volume adjustment
Front Back
Bakelite screw handle(M5×10)
Metal net cover
Product details
Product size
Product specifications
Product details / Product specifications / Product size
Power switch
Power socket
Working status indicator

Model
AP-DC2453
Input voltage
DC12V
Power 5.5W
Working voltage ±DC3000-DC5000V
Ion emission Steady-state DC
Emitter electrode Tungsten Alloy
Discharge structure Uncoupled electrical contact (discharge cylinder)
Discharge range 450*300mm(L*W)
Discharge speed ≤ 1.5s(150mm away from the air outlet)
Ion balance -15V ~ +15V(150mm away from the air outlet)
Alarm indicator The power indicator light on indicates working normally
Air volume ≤ 48.2CFM
Noise ≤ 38.9db(1m away from the air outlet)
Ozone thickness ≤ 0.05ppm(150mm away from the air outlet)
Working temperature 0-50℃
Working humidity 30-70%RH
Dimensions 85*54*112mm(L*W*H)(Fan body size)
Shell material Aluminum powder spray
Packaging accessories 1 pair of U-shaped aluminum spray powder mounting bracket, 1 pair of bakelite screw handles(M5×10)
Power adapter
INPUT:AC100-240V 50/60Hz;
OUTPUT:DC12V 1000mA
Net weight 350g(Fan body, including mounting bracket and screw handle)
Gross weight 600g
Warranty
Certification CE
Product specifications
1Year

1 2
Step of use
Installation position
Packing accessories
Wall
≥ 150mm
Wall Wall
≥ 200mm ≥ 200mm≥ 400mm
150~450mm
150~450mm
Power Adapter 0DYK00602 DSS28-1202000-F 100-240V~1.0A 50/60HZ 12V-2.0A
Products Use
Step of use/Installation position/Packing accessories
Take out the power adapter from the packing box and connect
the ionizing air blower.
Place the ionizing air blower close to the working area (about
150~450mm away from the object with electrostatic to
be eliminated), and the air outlet of the ionizing air blower
must be vertically aligned with the object to be
eliminated.
Use screws or bolts to fix on a firm and flat surface(such
as a wall or shelf). The angle of ionizing air blower can
be adjusted by the knobs on both sides of the bracket to
achieve the best static elimination effect.
1. Place the ionizing air blower in the working area where static electricity is to be eliminated. And the installation angle should be perpendicular to
the surface of the charged body and about 150 to 450 mm away from the static electricity object.
2. Ionizing air blower should be at least 300mm away from the metal conductor and metal grounding body.
3. Two ionizing air blowers should be installed side by side with an interval of more than 400mm and more than 200mm away from obstacles
such as walls.
4. The air inlet is at least 150mm away from the wall.
Part namePicturePart No.Specification

Safety warning
Trouble shooting
After-sales service
Maintenance
1. Read the operating instruction carefully before installing and using the device.
2. Do not use the device when the humidity is higher than 70%.
3. Do not use the device in inflammable and explosive environment.
4. It is strictly forbidden to disassemble products without authorization. Internal maintenance and repair must be carried out by
professional personnel.
5. The product is strictly prohibited to touch liquid during use, otherwise there will be abnormal, resulting in electric shock or fire.
6. Power must be turned off during inspecting or replacing the product, otherwise it may cause electric shock or fire.
7. The product is specially designed for removing static electricity and is strictly prohibited for other purposes. Any abnormal use may
cause machine failure, electric shock, fire and other hidden dangers.
8. It is strictly forbidden to touch the electrode needles when power is on, otherwise it is easy to cause fault and electric shock accident.
9. Discharge needle is a sharp metal object, please use it with care.
10.Please check the specifications of the power supply before powering on the product. Any power supply that does not meet the
specifications may cause damage or even failure to the product.
11.Check the power cord regularly. If it is damaged, replace it immediately; otherwise, leakage and abnormal operation may occur.
NO Problems Reasons Solutions
1The indicator on the fan
panel is off
Poor contact of the power cable Check whether the power cable is in good condition and
securely connected
Power supply mismatch Confirm the power supply specification(INPUT:100
—240VAC 50/60Hz;OUTPUT:12VDC 1000mA)
2
The electrostatic removal
performance is obviously
reduced
Discharge needle is polluted and damaged Clean or replace the discharge needle
Bearing set of ionizing air blower is improper Confirm the best bearing set
3The electrostatic removal
performance is reduced There are conductors or other ionizing air blowers around Remove (moving) conductors or other ionizing air blowers
4Unable to discharge High voltage module is damaged Return to factory for maintenance
Main-board chip is damaged Return to factory for maintenance
5The product is smoky or burnt The main control board components are burnt out Return to factory for maintenance
1. The ionizing air blower should be cleaned and maintained in time according to the use environment and the required electrostatic
protection requirements in order to ensure the good performance of the product. That is, gently remove the carbon deposits on the
discharge electrode and metal net cover with electrostatic brush, dust-free cotton swab, dust-free cloth dipped in anhydrous alcohol.
Note:
A、Operation must be done 10 minutes after power cut off.
B、It must be cleaned when dust or white stuff appear on the tip of the needle during use.
C、The ionizing air blower must be powered on after alcohol is completely volatilized after cleaning. No other organic solvent can
be used to clean the ionizing air blower.
D、The alloy electrode is a consumable product which is not included in the scope of warranty and will be charged for
replacement when repairing.
2. Do not press or rotate the control buttons on the fan panel too hard; otherwise, the device will be permanently damaged.
3. If the working indicator light on the front panel of the fan is off or red, it should be stopped and repaired by professional
maintenance personnel. It can be used only after the electrical performance index is normal.
1. AP- DC2453 mini ionizing air blower has undergone rigorous testing and aging treatment before ex-work. Its performance has
completely reached the relevant indicators marked in the usage instruction.
2. AP&T makes a commitment to the customer that any defective parts inspected by AP&T will be repaired or replaced free of charge
within one year from the date of purchase. However, this commitment does not apply to: The device is incorrectly used or installed;
Damage caused by negligence or accident during use; Modified, disassembled or repaired by other service departments not authorized by
Anping Company.
3. AP&T shall not be liable for any incorrect use of the products except for repair or replacement of parts as specified above.

专业创造价值
AP&T
Professional electrostatic intelligent monitoring/analysis
and elimination solution provider
Speciality Creates Value
AP&T
Shanghai Anping Static Technology Co.,Ltd
Tel : +86-21-64517676
Fax : +86-21-64517673
Postcode : 200233
Website : www.ap-static.com
Address : 3/F,Building 27,No.69,Guiqing Road,Shanghai,China
Other manuals for AP-DC2453
1
Table of contents
Other AP&T Blower manuals

AP&T
AP&T AP-DJ2814 User manual

AP&T
AP&T AP-DJ1811 User manual

AP&T
AP&T AP-DC2451-001 User manual

AP&T
AP&T AP-DC2453 User manual

AP&T
AP&T AP-DJ2813 User manual

AP&T
AP&T AP-DJ2811 User manual

AP&T
AP&T AP-AC2459 User manual

AP&T
AP&T AP-DJ1802 User manual

AP&T
AP&T AP-DJ2812 User manual

AP&T
AP&T AP-DC2451-001 User manual
Popular Blower manuals by other brands

RCm
RCm ATOM PLUS /1 Instruction and maintenance handbook

Stahlwerk
Stahlwerk SW500 instruction manual

All-Star Products
All-Star Products ALL-STAR HB Series Operation & maintenance instructions

DR.SCHNEIDER PC
DR.SCHNEIDER PC DC-003 Operation & maintenance instructions

Husqvarna
Husqvarna 536LiBX Workshop manual

Toro
Toro Flex-Force Power System Operator's manual