AP&T AP-DJ1811 User manual

Intelligent control ionizing air blower
AP-DJ1811
Shanghai Anping Static Technology Co.,Ltd
AP&T
R
AP&T
New Product
Intelligent Control Ionizing Air Blower

Effectively solve the problems
caused by static electricity
Suitable for electronics, optoelectronics,
semiconductor and other industries
Prevent adhesion of objects
Static removal Prevent blockage of feeder
Prevent static electricity
Prevent material splash

Network Monitoring
Multiple networking methods to monitor the
working status of ionizing air blower online
RS485
communication
AP-DY6703
AP-KT3701 AP-DY6704
USB wire link
USB wire link
IMS monitoring software
IMS monitoring software
IMS monitoring software

Intelligent Remote Control
Cleaning time /Air volume output adjustable
Cleaning time setting
Set a reminder for the cleaning time at will. Blue light flashes indicates cleaning is required. The electrode needle
cleaning cycle should be set according to the working environment when using the ionizing air blower. Cleaning
cycle should be shorten appropriately in environment with more moisture and dust.
Air volume output adjustable
Fan speed in five gears. Adjust the air volume according to the installation distance of the static eliminator and the
status of the target object.
Ion balance adjustable
The ion balance voltage can be adjusted by adjusting the negative high voltage
amplitude remotely.
Function Symbol Operation instructions
Unlock Unlock before adjusting operating parameters; 30s delay if any key is
pressed, exit and re-locked if no key is pressed.
Run / Pause Device starts running when power is on. Press "STOP" to standby and no
high voltage output. Press "RUN" again and the device will start working.
Clean Press the button to clean the needle once.
Adjust clean time CTTH → +/- Press CTTH first, and then press +/- to increase or decrease the
cleaning cycle. Minimum adjustment unit 1H.
Adjust air volume CFM → +/- Press CFM first, then press +/-,air volume from high to low is 1,2,3,4,5.
Adjust ion balance IBN → +/- Press IBN first, then press +/- to adjust the ion balance voltage.
Confirm CAL → OK Note: Press CAL first, then press OK to confirm after adjusting the
output parameter; otherwise, false alarms are likely to occur.
Reset Reset(150Hz、50%、4H):Press CAL first,then pressPress IBN first, then press + when the positive voltage on flat panel charge detector or object surface is high, press IBN first, then press - when
the negative voltage on flat panel charge detector or object surface is high until the ion balance reaches the ideal status.
CAL →
TIME TIME
Reduce the negative high voltage amplitude,
the negative ion output decreases
Adjust ion balance voltage
Button Function instructions

Pulse DC
Discharge effect is better compare to
frequency AC ionizing air blower
Pulse DC method generate ions with two polarity by
applying "+" and "-" high voltage alternately on positive
and negative electrode needles.
Compared with power frequency AC method, the
utilization rate of ion generation is higher. And its static
elimination ability can be exerted no matter in short or
long distance. In addition, the high voltage amplitude
can be adjusted, which is convenient for intelligent
control.
Pulse DC VS Traditional AC
AC
High voltage power supply
Power frequency AC
T
+HV
(Positive high voltage)
-HV
(Negative high voltage)
Pulse DC
Pulse DC
Positive pulse Negative pulse
T
Pulse DC
Positive voltage working time
Negative voltage working time
+HV
(Positive high voltage)
-HV
(Negative high voltage)
Positive voltage working time
Negative voltage working time

Keep a clean production environment and stay
away from static electricity
Ion balance distribution diagram of AP-DJ1811
Discharge time distribution diagram of AP-DJ1811
Note:The 0 point of the test length is the center position of the
air blower
Test standard:ANSI/ESD.STM3.1,SJ/T 11446—2013
Test instrument: Trek charge plate tester
Test voltage:±1000V → ±100V attenuation
Test environment:humidity 50±5%;temperature 23±3℃
Test bearing chart of single-port air blower
Z(mm)Trek 150*150mm flat tester
-150
X(mm)
150mm
300mm
450mm
900mm
600mm
750mm
150
0
-150 0 150
900
750
600
450
300
150
Test Height (mm)
0.4
1.5
2.7
3.8
5
6.2
7.3
8.4
9.6
11
12
Discharge Time(s)
Test Length (mm)
-150 0 150
900
750
600
450
300
150
-9
-7
-6
-4
-3
-1
0
2
3
5
Ion Balance(V)
High Efficiency Static Removal
Test Length (mm)
Test Height (mm)

No.1
No.2
No.4
Intelligent remote control
Ion output characteristics can be adjusted by remote
control.
8 Electrode needles
Multiple air outlets, 8 tungsten
electrode needles per air outlet with
longer life time.
No.3
Built-in cleaning brush
Automatic needle brushing function when start up. By
default, the needle is automatically brushed every 4 hours
for manual cleaning and maintenance free.
High voltage alarm
Display screen show fault alarm and LED red
light alarm when the fan and high voltage
breakdown.
Features
Safe / Easy to use / Durable

No.5
No.6
No.7
LED display
LED display shows the equipment address (e.g.A00),
wind speed gear (e.g.S1), cleaning cycle (e.g.T04),
temperature and humidity, cleaning indication (Cleaning),
fan fault alarm (Fan Fault!!) and HV fault alarm (HV
Fault!!)
High air volume fan five
speed adjustment
Stable performance and air volume output
1.45 times higher than ordinary fans.
CE certification
CE certified with electromagnetic protection function and
no electromagnetic interference to other equipment. It can
also effectively avoid external electromagnetic
interference affecting the normal operation of the air
blower which is a high-security and high-reliability static
eliminator.
No.8
Network Monitoring
Wired network communication
realisable and monitor the working
status of the air blower.
RS485
Communication
IMS monitoring software
Features
Safe / Easy to use / Durable

Temperature and humidity
(The temperature and humidity sensor is located inside the product)
Unlock / Lock
Run / Pause Fan No.
wind speed gear(5gears)
LCD display
Green light always on: normal Red light always on: fan fault alarm
Power interface cable function information
1、2 Orange
White-orange VCC:+24VDC
3Blue RS485+B
4White-blue RS485+A
5Green GND
6White-green GND
7Brown VTH:Sensor threshold alarm
HVAL:Eliminator high voltage alarm
8White-brown
Clean:Eliminator cleaning indication
9Metal shield PE
The output wiring diagrams of pins 7 and 8 are as follows:
8VKDSHGEUDFNHW
RJ45 power/communication interface
*URXQG6WXG
3RZHUVZLWFK
&OHDQingVZLWFK
$LUYROXPHDGMXVWPHQW
/('GLVSOD\
6WDWXV,QGLFDWRU
)URQW %DFN
%DNHOLWHVFUHZKDQGOH(0î)
)DQIURQWFRYHU )DQUHDUFRYHU
Product Use
3DQHOIXQFWLRQVspecificationGLPHQVLRQV
3DQHOIXQFWLRQV
Blue light flashes: cleaning indication
Blue light always on: pause/standby Red light flashes: high voltage fault alarm
Cleaning cycle
ACT:Sensor/eliminator power-on indication
HV Alarm signal:Normal--always open、Abnormal--always close Power signal :Normal--always close
cleaning signal:Clean--always open

Model AP-DJ1811
Input voltage DC 24V(RJ45 Interface)
Output voltage DC±4KV → ±6KV
Power 12W
Ion emission Pulse DC
Emitter electrode Tungsten alloy
Discharge range 750*300mm(L*W)
Air volume ≤ 135CFM*1
Noise Single air outlet≤ 58dBA(1000mm away from the air outlet)
Ozone thickness ≤ 0.05ppm(150mm away from the air outlet)
Ion balance ≤ |±10V|
Discharge speed ≤ 1.5S
(300mm away from the air outlet)
Status indicator
Power on/clean operation—blue light flashes;
Normal work—green light (always under monitoring status);
Fan fault alarm—red light always on;
High voltage fault alarm-red light flashes;
Infrared debugging/cleaning prompt-blue light flashing
Communication method RS485
Signal output RS485(115200bps,8,1,n,n)≥ 20ms
Collector open circuit:< 50V,100mA
Working temperature 0℃ -50℃
Working humidity < 70%RH
Dimensions 147*70.5*190mmmm(L*W*H)Ionizing Air Blower body size)
Shell material Aluminum powder spraying
Installation accessories 1 pair of U-shaped iron powder spraying mounting
brackets, 1 pair of bakelite screw handles(M5×8)
Power adapter INPUT:AC100—240V 50/60Hz;
OUTPUT:DC24V 2A(dual RJ45 Interface)
Weight 1.35KG(Including power cord and bracket)
Warranty 1Year
Certification CE
Specification
Unit:mm
Dimensions
Installation accessories
1 pair of U-shaped iron powder spraying
mounting brackets, 1 pair of bakelite
screw handles(M5×8)
147 70.5
156
190
200.5
60
152
117
Φ6.5×3
Φ6.5×2
102
30
10°
56 56
30
R6
20
1,5
60
20

1. Install the ionizing air blower and the matching power adapter firmly in the best discharge position.
2. Insert the power network cable into the adapter and the ionizing air blower RJ45 network port, and insert the
national standard power cable of the adapter into the row socket.
3. Touch the power switch on the front panel of ionizing air blower. It will automatically brush the needle after
starting and the fan works normally when the indicator light is green.
Installation steps
1. Place the ionizing air blower in the work area where static electricity is to be eliminated and the installation angle
is perpendicular to the surface of the charged body.
2. Ionizing air blower should be at least 300mm away from the metal conductor and metal grounding body. The
ionizing air blower must be reliably connected to the ground wire.
3. Two ionizing air blowers should be installed side by side with an interval of more than 400mm and more than
200mm away from obstacles such as walls.
Technical tips
Wall Wall
Wall
Packing accessories
Part namePicturePart No.SpecificationQ'TYPower adapterOSP000601 GRT-240200:DC24V 2A,Dual-port output,size:123*61*40.5mm(L*W*H)1National standard power cord8YXG25110 Standard 1.8m,Optional 3m/5m 1Power cable8WXI00004Standard 2.5m,Optional 5m/10m 1Remote controlAP2253011 IR remote control,84×38mm 1
Products Use
Installation steps/technical tips/Installation accessories
4. The air inlet is at least 150mm away from the wall.

No. Faults Reasons Solutions
1The indicator on the fan
panel is off
Poor contact of the power cable Check whether the power cable is in good condition and
securely connected
Power supply mismatch Confirm the power supply specification(INPUT:100—240VAC
50/60Hz;OUTPUT:24VDC 2000mA)
2
The electrostatic removal
performance decreased
obviously.
Discharge needle is polluted and damaged Clean or replace the discharge needle
The cleaning brush covers the electrode needle Brush the needle manually with the remote control, or shut down and
restart to keep the cleaning brush away from the electrode needle
Ionizing air blower is set incorrectly Confirm the best installation location
3The electrostatic removal
performance decreased
There are conductors or other
ionizing air blower around
4High voltage alarm(Panel
indicator light flashes red)
Electromagnetic interference Turn off the power switch / unplug the power cable, restart
the ionizing air blower
Abnormal discharge Confirm whether the electrode needle is close to or touching
the metal conductor, and remove foreign objects
No power supply for high voltage module Return to factory for maintenance
High voltage module is damaged Return to factory for maintenance
5Fan alarm(Panel indicator red
light always on)
Fan fault Return to factory for maintenance
The fan power supply or control circuit is damaged Return to factory for maintenance
6Unable to discharge
Return to factory for maintenance
Main-board chip is damaged Return to factory for maintenance
Poor grounding / chip damage caused by no grounding Check the grounding of the ionizing air blower and plant equipment,
and return to the factory for maintenance
7The display is off or flickering
Abnormal discharge Return to factory for maintenance
High voltage module is damaged Return to factory for maintenance
Poor grounding or wrong product power supply line
8The product is smoky or burnt The high-voltage module is damaged or the insulation
of the discharge bracket is damaged Return to factory for maintenance
1. Please read the instruction manual carefully before installing and using this equipment.
2. The whole set of equipment must be reliably grounded during use, and the connection resistance of the electrical connection to the AC
equipment ground should be less than 1 ohm.
3. Do not use this equipment in environment where humidity is > 70%..
4. It is strictly forbidden to use this equipment in flammable and explosive environments.
5. Unauthorized disassembly of the product is strictly prohibited, internal maintenance and repair must be performed by professionals.
6. The product is strictly prohibited to touch liquid during use, otherwise an abnormality may occur and cause electric shock or fire.
7. Power must be turned off during inspecting or replacing the product, otherwise it may cause electric shock or fire.
8. The product is specially designed to eliminate static electricity. It is strictly forbidden to use it for other purposes. Any abnormal use may
cause machine failure, electric shock, fire and other accidents.
9. It is strictly forbidden to touch the electrode needles when power is on, otherwise it is easy to cause malfunctions and electric shock
accidents.
10.The electrode needle is a sharp metal object, please use it with care.
11. Please check the specifications of the power supply before powering on the product. Any power supply that does not meet the
specifications will cause damage to the product.
12.Please check the product power cord/communication cord regularly, and replace it immediately if it is damaged, otherwise it is easy to
cause problems such as electric leakage, poor communication, and abnormal operation.
Safety warning
Trouble shooting
Remove (moving) conductors or other ionizing air blowers
High voltage module is damaged
Check the grounding of the ionizing air blower and plant equipment,
and return to the factory for maintenance

1. In order to ensure the good performance of the product, the fan should be cleaned and maintained in time according to the use environment
and the required electrostatic protection requirements, that is, using electrostatic brush, dust-free cotton swab, dust-free cloth dipped in
anhydrous alcohol to gently remove the dust on the electrode, discharge bracket, fan and metal mesh cover. Note:
A. Operation must be done 10 minutes after power cut off.
B. The cleaning cycle of the electrode needle should be set according to the working environment during use of the fan. It should be
appropriately reduced in the environment with more humid and dusty.
C. The fan must be powered on after alcohol is completely volatilized after cleaning. No other organic solvent can be used to clean the fan.
D. The alloy electrode is a consumable product which is not included in the scope of warranty and will be charged for replacement when
repairing.
2. Do not press or rotate the control buttons on the fan panel too hard; otherwise, the device will be permanently damaged.
3. If the working indicator light on the front panel of the fan is off or red, it should be stopped and repaired by professional maintenance
personnel. It can be used only after the electrical performance index is normal.
Maintenance
AP-DJ1811 ionizing air blower has undergone rigorous testing and aging treatment before ex-work. Its performance has completely reached
the relevant indicators marked in the usage instruction.
AP&T makes a commitment to the customer that any defective parts inspected by AP&T will be repaired or replaced free of charge within one
year from the date of purchase. However, this commitment does not apply to:
1. The device is incorrectly used or installed.
2. Damage caused by negligence or accident during use;
3. Modified, disassembled or repaired by other service departments not authorized by Anping Company.
AP&T shall not be liable for any incorrect use of the products except for repair or replacement of parts as specified above.
After-sales service

AP&T
Professional electrostatic intelligent monitoring/analysis
and elimination solution provider
专业创造价值
Shanghai Anping Static Technology Co.,Ltd
Tel : +86-21-64517676
Fax : +86-21-64517673
Postcode : 200233
Website : www.ap-static.com
Address : 3/F,Building 27,No.69,Guiqing Road,Shanghai,China
Speciality Creates Value
Table of contents
Other AP&T Blower manuals

AP&T
AP&T AP-DC2451-001 User manual

AP&T
AP&T AP-AC2459 User manual

AP&T
AP&T AP-DC2451-001 User manual

AP&T
AP&T AP-DC2452-60C User manual

AP&T
AP&T AP-DC2453 User manual

AP&T
AP&T AP-DJ2813 User manual

AP&T
AP&T AP-DJ2811 User manual

AP&T
AP&T AP-DJ1802 User manual

AP&T
AP&T AP-DJ2814 User manual

AP&T
AP&T AP-DC2453 User manual
Popular Blower manuals by other brands

Badger Basket
Badger Basket 2060 Series II Operator's manual

Makita
Makita XBU02 instruction manual

Ikra
Ikra BVN 2200 operating instructions

CleanCraft
CleanCraft HKM 700 operating instructions

Black & Decker
Black & Decker Leaf Hog 617365-00 instruction manual

Cincinnati Fan
Cincinnati Fan CPF Installation, safety, operation & maintenance manual amd parts list