TROUBLESHOOTING
POSSIBLE CAUSES
UNIT DOES NOT START
●Unit may have become unplugged
●Fuse may have blown
●Circuit breaker may have been tripped
●Unit may be off at wall thermostat.
●
Unit may be in a protection or diagnostic failure
mode. See section on diagnostic codes.
●
●
●
●
●
●
●
●
●
●
●
DISPLAY HAS STRANGE NUMBERS/CHARACTERS
ON IT
UNIT MAKING NOISES
UNIT NOT COOLING / HEATING ROOM
Unit air discharge section is blocked
Temperature setting is not high or low enough
Note: Setpoint limits may not allow the unit to heat or
cool the room to the temperature desired. Check section
on temperature limiting in wall thermostat manual.
Unit air filters are dirty.
Room is excessively hot or cold when unit is started
Vent door open
Unit may be in a protection or diagnostic failure mode.
WATER DRIPPING OUTSIDE
WATER DRIPPING INSIDE
Wa not installed levelll plenum is
ICE OR FROST FORMS ON INDOOR COIL
Low outdoor temperature
Dirt rsy air filte
COMPRESSOR PROTECTION
Compressor operation may have been interrupted,
so compressor is in a restart delay.
SOLUTIONS
Check that plug is plugged securely in wall receptacle.
Note :Plug has a test/reset button on it. Make sure that the
plug has not tripped.
Replace the fuse.
Reset circuit breaker.
Turn unit on to heating or cooling mode wallat
The unit may be in a diagnostic condition. Check
--- checking Control section to determine
if unit has had a failure.
The unit may be set for ° C (instead of ° F), see the keypad
configuration section
Clicking, gurgling and whooshing noises are normal during
operation of unit.
Make sure that curtains, blinds or furniture are not restricting or
blocking unit airflow.
Reset to a lower or higher temperature setting.
Remove and clean filters.
Start heating or cooling early before outdoor temperature, cooking
heat or gatherings of people make room uncomfortable.
Close vent door.
Check section on diagnostic codes.
Wait approximately 3 minutes for compressor to start
If d, condensation an internal drain system has not been installe
run off to the outdoors during very hot and humid weather is
normal. The external drain tube will discharge the condensate out
beyond the real louver.
Wall ust be installed for proper drainage ofplenum m
condensation. Check that installation is properly leveled according
to installation instructions and make any necessary adjustments.
Random Compressor restart—Whenever the unit is
plugged in, or power has been restored a random
compressor restart will occur. After a power outage, the
compressor will restart after approximately 3 minutes.
Compressor Protection — To prevent short cycling of the
compressor, there is a random startup delay of 3 minutes.
●
●
●
●
●
diagnostic codes
●
●
●
●
●
●
●
●
●
●
●
Remove then clean or replace air filters as applicable.
●
●
●
-17-
thermostat system switch.
Compressor is in time delay. There is a protective time delay
(approx . 3 minutes) on starting the compressor after a power
outage (or restarting after it has been turned off ), to prevent
tripping of the compress or overload.