Step 3. Connect the output connectors of RSD-D in series to the string, the string open-air
DC voltage is within the range of (1.2 ~ 2v) X #RSD-Ds. (This range may vary due to different
on-site environment.)
NOTE: Do not connect homerun to inverter before finishing all strings connections and tests.
WARNING: When connecting the RSD-D to only one PV module, use INPUT1 port ONLY, then short both terminals
of INPUT2 directly or by extension cable, otherwise the RSD-D may be damaged. The DC output voltage remain
same.
√
×
×
2021/08/06 Rev2.5 | Quick Installation Guide2
Product information is subject to change without notice.(Please download manuals at www.APsmartglobal.com).
APsmart
600 Ericksen Ave NE, Suite 200 Seattle, WA 98110 | +1-737-218-8486
+1-866-374-8538 | APsmartglobal.com | support@APsmartglobal.com
Bending Radius of the cable >50mm
NOTE: When installing RSD-D cable, the bending radius of the cable near the casing must be greater than 50 mm.
√