manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Aquagarden
  6. •
  7. Other
  8. •
  9. Aquagarden Marlin 300 User manual

Aquagarden Marlin 300 User manual

This manual suits for next models

2

Popular Other manuals by other brands

Opticon EduMic Compatibility guide

Opticon

Opticon EduMic Compatibility guide

Kessil A360W owner's manual

Kessil

Kessil A360W owner's manual

TEFAL ULTRA COMPACT MIXER manual

TEFAL

TEFAL ULTRA COMPACT MIXER manual

Martin Audio WS18X - SCHEMATICS manual

Martin Audio

Martin Audio WS18X - SCHEMATICS manual

Hendrickson AR2 series Service instructions

Hendrickson

Hendrickson AR2 series Service instructions

GO Industries 38017 installation instructions

GO Industries

GO Industries 38017 installation instructions

Cissell 30LBCMAN2 manual

Cissell

Cissell 30LBCMAN2 manual

RIDGID K-60SP manual

RIDGID

RIDGID K-60SP manual

Gage Bilt GB751SH-5 Original instructions

Gage Bilt

Gage Bilt GB751SH-5 Original instructions

OVE SIERRA 60 installation manual

OVE

OVE SIERRA 60 installation manual

ReelCraft 7800 OLB21 operating instructions

ReelCraft

ReelCraft 7800 OLB21 operating instructions

Body Armor 4x4 ECO-SERIES user manual

Body Armor 4x4

Body Armor 4x4 ECO-SERIES user manual

ROBLIN DROP Dimensions

ROBLIN

ROBLIN DROP Dimensions

EMG EMG-ACB BARREL Installation information

EMG

EMG EMG-ACB BARREL Installation information

MiniSolar MT-150 Assembling Guide

MiniSolar

MiniSolar MT-150 Assembling Guide

Parkside PSZ 250 B2 Operation and safety notes

Parkside

Parkside PSZ 250 B2 Operation and safety notes

ABB REM 610 Technical reference manual

ABB

ABB REM 610 Technical reference manual

Tyent ACE-13 user manual

Tyent

Tyent ACE-13 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

®
Aquagarden,
4 Kingscote Street, Kewdale,
Western Australia, 6105.
www.aquagarden.com.au www.aquagarden.co.nz
Instruction Manual
Models 300, 450, 650
Before installing and operating your pump,
please read this Instruction Manual thoroughly
and retain it for future reference.
Waterfall, Filtration And Pond Pump
Thank you for purchasing anAquagarden Waterfall, Filtration and Pond Pump. It features ceramic bearings for
long life and an energy saving asynchronous motor that makes it economical to run. For optimum performance
and safety please read these instructions carefully and completely before installing and operating this pump.
Guarantee
This pump has been manufactured using only quality materials and accurate manufacturing processes to
provide the highest satisfaction and long life.We provide a guarantee of 24 months from date of purchase
on the pump motor.This guarantee does not cover parts subjected to natural wear and tear, such as
impellers, or any damages that result from misuse, tampering (including shortening of the cable), negligence,
damage and technical modication, or from not observing the General and Electrical Safety Instructions
above.
We reserve the right to repair or replace the unit. No repairs or replacement will be undertaken for
pumps that have not been properly maintained.The guarantee will be honored only if the unit is returned
to your supplier complete, with your receipt or proof of purchase of the product.
650
Features
1. Precise high aluminum ceramic shaft for fresh and sea water dual use.
2. Double water-cooled structure for rapid heat dissipation.
3.Adopts high quality resin to seal the winding and never leak electricity.
4. Super quality ABS plastic housing, which is anticorrosive and anti-striking.
5. Can be operated submersible or in-line.
Functions
1. It is used for supplying and draining fresh/sea water.
2. It is used for water supplying and draining for sea sh breeding pond.
3. It is used for wave-making for aquarium, garden watering, water supplying and circulating for rockery,
fountain, landscape, water cleaning and draining for under-ground pond.
Mounting Instructions
If the immersible pump will be used inside water, place the pump with front cover, lter sponge and lter
case and water outlet adapter in desired place, position suction cups on pump and attach to aquarium or
other place before connecting power source. Do not put the plug together with the pump into water.If the
plugdrops into water, power supply should be turned off immediately so as to avoid electric shock. If the pump
will be used outside water, mount it with water intake, outlet adapters & pipe on a at and solid base. Remove
the power supply cord from socket before doing any maintenance or cleaning work.The pump can be used in
doors.The power supply cord cannot be changed or replaced. It must not be bent or used to carry the pump.
If the cord is damaged, do not use the pump.
Operational Instructions
During Operation
If clogging of the lter cover inlet occurs, shut off the power immediately.
If the pump does not operate as it should after cleaning, please consult your local Aquagarden stockist to
establish the cause of the problem.
If freezing temperatures are forecast, switch off the pump, remove it from the water and store it after cleaning
and drying the impeller chamber completely.
After periods of inoperation
If the pump is left submerged in pond water for a long period of time without operation, it could lead to the
accumulation of debris inside the pump. Clean the pump and run it in clean water for a few minutes before
returning the pump to the pond.
General Safety Instructions
1. Only use this pump with the voltages specied on the pump label.
2. Disconnect the mains supply before handling the pump in any way.
3. Never operate the pump when people are in contact with the water.
4. Never carry, lift, lower or pull the pump by the cable.
Electrical Safety Instructions
1. Always operate the pump at voltages between 220 & 240 volts.
2. For outdoor use, the plug must be connected to a weatherproof socket.
3. The electricity supply circuit must be tted with a suitable fuse or a Residual Current Device (RCD), also
known as a Residual Current Circuit Breaker (RCCB), with a tripping current not exceeding 30 mA.
4. It is necessary to conform to the regulations of the local electricity authority that may require additional
cable protection.There may also be building regulations covering the installation of pumps and ponds.
5. The electrical cable is permanently connected and sealed into the pump. Should the cable become
damaged, it cannot be repaired or replaced and the pump should be discarded.
General Maintenace & Cleaning
While the water chamber has a very effective self cleaning feature, any apparent reduction in the water
ow rate from your pump usually indicates that it requires cleaning. Regular cleaning and maintenance will
signicantly lengthen the life of the impeller and the motor unit.
To clean your pump:
1. First disconnect it from the mains supply and press in the two sides of the water inlet cover to remove it
from the water chamber housing.
2. Now undo the 4 screws that connect the water chamber housing to the motor body and remove the
water chamber to reveal the impeller.
3. Remove and check the impeller and rotor for dirt and grime and clean all parts in clean water. Do not use
hard objects, aggressive cleaning agents, or high-pressure machines.
4. Rinse all parts thoroughly in clean water and reassemble and reinstall your pump following the Installation
Instructions above.
Performance Curve
Performance Chart
MODEL 300 450 650
Power 5.0W 6.0W 8.0W
Max Flow 300L/h 450L/h 650L/h
Max Head 0.65m 0.73m 1.2m
Cable length 3m 3m 3m
A guide to simple problem solving
If you encounter a problem with this pump, before returning it to your Aquagarden stockist please check the
following chart for a possible cause and solution to your problem.
SYMPTOM PROBABLE CAUSES COUNTERMEASURE
The pump does not run
Power is not turned on Turn on the power
Improperly plugged in Push the plug fully into the socket
Blocked impeller Unplug the pump and remove foreign
matter from impeller
The motor turns on and
off repeatedly without the
pump running, or the motor
suddenly stops and cannot be
started again
The water inlet or outlet pipe is
clogged with debris
Unplug the pump and remove foreign
matter from the pipes
The pump runs normally to
start with but the water ow
reduces or there is no water
ow at all
Impeller is worn out and needs
replacing
Replace the impeller with a new one
from your Aquagarden stockist
The water level in the pond is too low,
exposing the pump to the air
Ensure that the pump is fully
submerged under water and, if
necessary, top up the pond
A hose is too long or clogged with
debris
Shorten the hose and / or clear the
blockage
There is air in the impeller chamber
(only applicable when the pump is
located out of water)
To remove the air, submerge the pump
under water and switch ON and OFF
two or three times
450
650
300
0.10 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 1.1 1.2 1.3 1.4
100L/Hr
200L/Hr
300L/Hr
400L/Hr
500L/Hr
600L/Hr
700L/Hr