Wiring the oil pressure shut down system
Connect the supplied red jumper between the terminal marked IGN and IGN IN. Any accessories you wish to turn on
with the ignion switch but not be controlled by the oil pressure switch can also be connected to IGN.
Connect IGN OUT to your ignion system turn on lead.
Connect the OPS OUT to one terminal of the oil pressure switch. Connect OPS IN to the other terminal on the oil
pressure switch.
If a bad oil pressure switch is suspected the bypass switch can be moved in the direcon of the arrow to bypass the oil
pressure switch.
When the system is funconing correctly with adequate oil pressure the IGN, IGN IN & IGN OUT green LEDs will all be lit
when the car is running. If the car shuts off and the green IGN OUT LED is out but the IGN and IGN IN LEDs are sll, lit
that indicates that the engine was shut off by the oil pressure shutdown circuit.
General Troubleshoong
Starter switch is dim and will not work - shier is not in park or neutral or neutral safety switch is not connected or is
defecve. A neutral safety switch must be connected to the terminals marked N/S for the starter switch to light up bright
and work.
Some switches won’t turn on/switches randomly shung off - tan circuit breaker must be set to correct baery voltage
posion for the car. Move the breaker to the correct terminals for the baery in the car (12V terminals for 12V baery
16V terminals for 16V baery).
Check for a weak baery. A weak baery can have enough Voltage to light up the switch panel, but when switches are
turned on, the load from accessories will cause the baery voltage to sag low enough to unlatch the relays. Make sure
the baery is fully charged and have the baery load tested or try another known good baery.
Ignion shung on and off - Oil pressure switch seng is too low, or oil pressure switch is defecve. Set bypass switch to
bypass posion to test. Also check the wiring to the oil pressure switch for damage. If the wiring to the oil pressure
switch is allowed to short to chassis ground an internal fuse will trip to protect the relay board. The fuse will automacally
reset once the fault is corrected. Check the wires to the oil pressure switch and replace any damaged wiring.
Switch panel geng hot - Tan 12V/16V circuit breaker is in the wrong Voltage posion. Move the breaker to the correct
seng for the baery voltage in the car.
Switch panel not working correctly, and all/some lights are off - Make sure the ribbon cable is plugged into the relay board
correctly. It is possible to plug the ribbon cable into the relay board connector off center. Unplug the connector and plug
it back in making sure the pins are centered le to right on the connector.
Check the tan circuit breaker. If the tan 5 Amp circuit breaker is tripped, the ribbon cable insulaon is damaged and is
shorng to ground. Inspect the ribbon carefully for faults. Do not change or alter the 5 Amp circuit breaker or damage to
the board will occur voiding the warranty. If this breaker is tripping, there is a fault with the ribbon cable.
Check the terminal marked GND on the relay board. This terminal must go to a good chassis ground for proper
operaon.
Make sure the ribbon cable plug in the switch panel is oriented with the red tape marks aligned.
Switches working erracally, buzzing sounds - Do not use a baery charger as a power supply to operate the switch
panel. Baery chargers can output a rippling DC voltage that will cause electronics to malfuncon. The switch
panel should only be operated when connected to a 12V or 16V baery. When charging the baery, the master
disconnect switch for the car should be turned off.
Switches working erracally, buzzing sounds - Do not use a baery charger as a power supply to operate the switch
panel. Baery chargers can output a rippling DC voltage that will cause electronics to malfuncon. The switch
panel should only be operated when connected to a 12V or 16V baery. When charging the baery, the master
disconnect switch for the car should be turned off.