Argo ADG ECO 35PH Operating manual

PACKAGE DCI R32
Duct Type Indoor Units
User and installation manual
Models:
:Indoor Unit :
ADG ECO 35PH
ADG ECO 50PH
ADG ECO 70PH ADG ECO 70PHB
ADG ECO 85PH
ADG ECO 100PH
ADG ECO 140PH
ADG ECO 85PHB
ADG ECO 160PH
ADG ECO 100PH
ADG ECO 140PH
Outdoor Unit:
AEG ECO 35PIH
AEG ECO 50PIH
AEG ECO 70PIH
AEG ECO 85PIH
AEG ECO 100PH
AEG ECO 140PIH
AEG ECO 160PIH3
AEG ECO 100PIH3
AEG ECO 140PIH3

ToUsers
Please read this instruction manual carefully before installing and using the
product, so as to master and correctly use the product. In order to guide you
to correctly install and use our product and achieve expected operating effect,
we hereby instruct as below:
(1) This appliance can be used by children aged from 8 years and above and
persons with reduced physical, sensory or mental capabilities or lack of
experience and knowledge if they have been given supervision or
instruction concerning use of the appliance in a safe way and understand
the hazards involved. Children shall not play with the appliance. Cleaning
and user maintenance shall not be made by children without supervision.
(2) In order to ensure reliability of product, the product may consume some
power under stand-by status for maintaining normal communication of
system and preheating refrigerant and lubricant. If the product is not to be
used for long, cut off the power supply; please energize and preheat the
unit in advance before reusing it.
(3) Please properly select the model according to actual using environment;
otherwise it may impact the using convenience.
(4) This product has gone through strict inspection and operational test
before leaving the factory. In order to avoid damage due to improper
disassembly and inspection, which may impact the normal operation of
unit, please do not disassemble the unit by yourself. You can contact with
the special maintenance center of our company if necessary.
(5) When the product is faulted and cannot be operated, please contact with
our maintenance center as soon as possible by providing the following
information.
1) Contents of nameplate of product (model, cooling/heating capacity,
product No, ex-factory date).
2) Malfunction status (specify the situations before and after the error
occurs).
(6) All the illustrations and information in the instruction manual are only for
reference. In order to make the product better, we will continuously
conduct improvement and innovation. We have the right to make

necessary revision to the product from time to time due to the reason of
sales or production, and reserve the right to revise the contents without
further notice.
(7) Indoor unitmust not be installed in a laundry.
(8) If the supply cord is damaged, it must be replaced by the manufacturer, its
service agent or similarly qualified persons in order to avoid a hazard.
(9) ArgoClima assumes no responsibility for personal injury,property loss
or equipment damage caused by improper installation and
commissioning, unnecessary maintenance, or not following
relevant national rules and regulations, industrial standards and
requirements in this instruction manual.
(10) The final right to interpret for this instruction manual belongs to
ArgoClima.
Exception Clauses
Manufacturer will bear no responsibilities when personal injury or property loss
is caused by the following reasons:
(1) Damage the product due to improper use or misuse of the product.
(2) Alter, change, maintain or use the product with other equipment without
abiding by the instruction manual of manufacturer.
(3) After verification, the defect of product is directly caused by corrosive gas;
(4) After verification, defects are due to improper operation during
transportation of product.
(5) Operate, repair, maintain the unit without abiding by instruction manual or
related regulations.
(6) After verification, the problem or dispute is caused by the quality
specification or performance of parts and components that produced by
other manufacturers.
(7) The damage is caused by natural calamities, bad using environment or
force majeure.

Contents
1 Safety Notice (Please be sure to abide)........................... 1
2 Product Introduction ......................................................... 5
2.1 Overall Layout........................................................................5
2.2 Operating Range....................................................................6
2.3 Standard Accessories.............................................................6
3 Installation.......................................................................... 7
3.1 Installation Preparation ..........................................................7
3.2 Unit Installation ....................................................................19
3.3 Electrical Installation ............................................................41
3.4 Check after Installation.........................................................59
3.5 Test Running ........................................................................59
4 Installation of Controller ................................................. 60
5 Maintenance..................................................................... 61
5.1 Failures Not Caused by Faults of the AC..............................61
5.2 Error Code ...........................................................................63
5.3 Unit Maintenance .................................................................65
5.4 Notice on Maintenance ........................................................67
5.5 After-sales Services .............................................................73
This marking indicates that this product should not be disposed with
other household wastes throughout the EU. To prevent possible harm
to the environment or human health from uncontrolled waste disposal,
recycle it responsibly to promote the sustainable reuse of material
resources. To return your used device, please use the return and collection systems
or contact the retailer where the product was purchased. They can take this product
for environmental safe recycling.

DC Inverter Package R32 Duct Type Unit
1
1 Safety Notice (Please be sure to abide)
SPECIAL WARNING:
(1) Be sure to comply with national gas regulations.
(2) Do not pierce or burn.
(3) Do not use means to accelerate the defrosting process or to clean, other
than those recommended by the manufacturer.
(4) Be aware that refrigerants may not contain an odor.
(5) Appliance shall be installed, operated and stored in a room with a floor
area larger than“X” m2(“X”see section 3.1.1).
(6) The appliance shall be stored in a room without continuously operating
ignition sources (for example: open flames, an operating gas appliance or
an operating electric heater).
PROHIBITED: This sign indicates that the operation must be prohibited.
Improper operation may cause severe damage or death to people.
WARNING: If not abide strictly, it may cause severe damage to the unit or
the people.
NOTE: If not abide strictly, it may cause slight or medium damage to the
unit or the people.
OBSERVED: This sign indicates that the items must be observed.
Improper operation may cause damage to people or property.
WARNING:
This product can’t be installed at corrosive, inflammable or explosive
environment or the place with special requirements, such as kitchen. Otherwise, it
will affect the normal operation or shorten the service life of the unit, or even cause
fire hazard or serious injury. As for above special places, please adopt special air
conditioner with anti-corrosive or anti-explosion function.
Please read this operating manual carefully before operating the unit.
The air conditioner is charged with inflammable refrigerant R32 (GWP:
675).
Before using the air conditioner, please read the instruction manual.

DC Inverter Package R32 Duct Type Unit
2
Before installing the air conditioner, please read the instruction manual.
Before repairing the air conditioner, please read the instruction manual.
The figures in this manual may be different with the material objects,
please refer to the material objects for reference.
PROHIBITED!
(1) The air conditioner should be grounded to avoid electric shock. Do not connect
the ground wire to gas pipe, water pipe, lightning arrester or telephone wire.
(2) The appliance shall be stored in a well-ventilated area where the room size
corresponds to the room area as specified for operation.
(3) The appliance shall be stored in a room without continuously operating open
flames (for example an operating gas appliance) and ignition sources (for
example an operating electric heater).
(4)
According to federal/state/local laws and regulations, all packages and
transportation materials, including nails, metal or wooden parts, and plastic
packing material, must be treated in a safe way.
WARNING!
(1) Please install according to this instruction manual.
Installation must be
performed in accordance with the requirement of NEC and CEC by authorized
personnel only.
(2) Any person who is involved with working on or breaking into a refrigerant
circuit should hold a current valid certificate from an industry-accredited
assessment authority, which authorises their competence to handle
refrigerants safely in accordance with an i
ndustry recognised assessment
specification.
(3)
Servicing shall only be performed as recommended by the equipment
manufacturer. Maintenance and repair requiring the assistance of other skilled
personnel shall be carried out under the supervision of the person competent
in the use of flammable refrigerants.
(4) The appliance shall be installed in accordance with national wiring regulations.
(5) The fixed wires connecting to the appliance must be configured with all-pole
disconnection device under voltage grade III according to wiring rules.
(6) Air conditioner should be stored with protective measures against mechanical
damage caused by accident.
(7) If the installation space for air conditioner pipe is too small, adopt a protective
measure to prevent the pipe from physical damage.

DC Inverter Package R32 Duct Type Unit
3
WARNING!
(8)
During installation, use the specialized accessories and components,
otherwise water leakage, electric shock or fire hazard may occur.
(9) Please install the air conditioner in a secure place that can withstand the
weight of air conditioner. Insecure installation may cause the air conditioner
falling down and lead to injury.
(10) Be sure to adopt independent power circuit. If the power cord is damaged, it
must be repaired by the manufacturer, service agent or other professional
agents.
(11) The air condit
ioner can be cleaned only after it is turned off and
power-disconnected, otherwise electric shock may occur.
(12) The air conditioner is not intended to be cleaned or maintained by children
without supervision.
(13) Do not alter the setting of pressure sensor or other protective devices. If the
protective devices are short-circuited or changed against rules, fire hazard or
even explosion may occur.
(14) Do not operate the air conditioner with wet hands. Do not wash or sprinkle
water on the air conditioner, otherwise malfunction or electric shock will occur.
(15) Do not dry the filter with naked flame or an air blower; otherwise the filter will
be out of shape.
(16) If the unit is to be installed in a small space, please adopt protective measures
to prevent the concentration of refrigerant from exceeding the allowable safety
limit; excessive refrigerant leakage may lead to explosion.
(17) When installing or re-installing the air conditioner, please keep the refrigerant
circuit away from substances other than the specified refrigerant, such as air.
Any presence of foreign substances will cause abnormal pressure change or
even explosion, resulting in injury.
(18) Only professionals are allowed to carry on daily maintenance.
(19) Before contacting any wire, make sure power is cut off.
(20) Do not let any inflammable objects near the unit.
(21) Do not use organic solvent to clean the air conditioner.
(22) If you need to replace a component, please ask a professional to repair with a
component supplied by the original manufacturer so as to ensure the unit’s
quality.
(23) Improper operation may get the unit broken, hit by electric shock or cause fire.
(24) Do not make the air conditioner wet or electric shock may be lead, ensure that
the air conditioner will not be cleaned by water rinsing under any
circumstance.
(25) When you do not connect the duct, you need to provide an extra protective net
to avoid touching the basic insulation.

DC Inverter Package R32 Duct Type Unit
4
NOTES!
(1) Do not put a finger or other objects into the air inlet or air return grill.
(2) Please adopt safety protection measures before touching the refrigerant pipe;
otherwise your hands may be hurt.
(3) Please arrange the drain pipe according to the instruction manual.
(4) Never stop the air conditioner by directly cutting off the power.
(5) Please select the proper copper pipe according to the requirement for pipe
thickness.
(6) Indoor unit can only be installed indoors while outdoor unit can be installed
either indoors or outdoors. Never install the air conditioner in the following
places:
1) Places with oil smoke or volatile liquid: plastic parts may deteriorate and fall
off or even cause water leakage.
2)
Places with corrosive gas: copper pipe or the welding parts may be
corroded and cause refrigerant leakage.
(7) Adopt proper measures to protect the outdoor unit from small animals because
they may damage the electric components and cause malfunction of the air
conditioner.
(8) Before cleaning, please make sure the unit is stopped. Cut the circuit breaker
and remove the power socket, otherwise, electric shock may occur.
(9) Do not wash the air conditioner with water, otherwise fire hazard or electric
shock may occur.
(10) When cleaning the filter, please be careful of your steps. If you need to work
high above the ground, please be extremely careful.
OBSERVED!
(1) If wired control is to be used, it should be connected first before powering up
the unit, otherwise the wired control may not be able to use.
(2) When installing the indoor unit, keep it away from television, wireless waves,
and fluorescent.
(3) Only use soft dry cloth or slightly wet cloth with neutral detergent to clean the
casing of the air conditioner.
(4) Before operating the unit under low temperature, connect it to power for 8
hours. If it is stopped for a short time, for example, one night, do not cut off the
power (This is to protect the compressor).

DC Inverter Package R32 Duct Type Unit
5
2 Product Introduction
2.1 Overall Layout
NOTES:
(1) The connection pipe, drain pipe, power cord, and duct for this unit should
be prepared by the user.
(2) The unit is standard equipped with rectangular duct.

DC Inverter Package R32 Duct Type Unit
6
2.2 Operating Range
Cooling Heating
Outdoor temperature DB(°C) -20~48 -20~24
Indoor temperature DB/WB(°C)(Maximum) 32/23 27/-
2.3 Standard Accessories
Indoor Unit Accessories
No. Name Appearance Q'ty Usage
1 Wired
Controller 1 To control the indoor unit.
2 Nut with
Washer
4 To fix the hook on the cabinet of
the unit.
3 Nut 4
To be used together with the
hanger bolt for installing the
unit.
4 Washer 4
To be used together with the
hanger bolt for installing the
unit.
5 Insulation 1 To insulate the gas pipe.
6 Insulation 1 To insulate the liquid pipe.
7 Fastener 8 To fasten the sponge.
8 Sponge 2 To insulate the drain pipe.
9 Sponge 1
To insulate the Fresh air inlet
(Only for GUD100-160PH/A-T
and GUD100-160PHS/A-T).
10
Removal-
Proof screw
Nut
1 To connect gas pipe.
11
Removal-
Proof screw
Nut
1 To connect liquid pipe.
Outdoor Unit Accessories
No. Name Appearance Q'ty Usage
1 Drain Plug 1 or 3 To plug the unused drain hole.
2
Drainage
Connector
or 1
To connect with the hard PVC
drain pipe.

DC Inverter Package R32 Duct Type Unit
7
3 Installation
3.1 Installation Preparation
3.1.1 Notice on Installation
(1) Notice on Refrigerant Concentration before Installation.
This air conditioner uses R32 refrigerant. The construction area for installation,
operation and storage of the air conditioner must be larger than the minimum
construction area. The minimum area for installation is determined by:
1) Refrigerant charging quantity for the entire system (ex-factory
charging quantity + additional charging quantity).
2) Checking out in the applicable tables:
A. For indoor unit, confirm the model of indoor unit and check the
corresponding table.
B. For outdoor unit that is installed or placed indoors, select the
corresponding table according to the height of the room.
Height of the room
Select the applicable table
<1.8m Floor standing type
≥1.8m
Wall mounted type
3) Refer to the following table to check out the minimum construction
area
Ceiling type Wall mounted type Floor standing type
Weight(kg) Area (m2) Weight(kg) Area (m2) Weight (kg) Area (m2)
<1.224
—
<1.224
—
<1.224
—
1.224 0.956 1.224 1.43 1.224 12.9
1.4 1.25 1.4 1.87 1.4 16.8
1.6 1.63 1.6 2.44 1.6 22.0
1.8 2.07 1.8 3.09 1.8 27.8
2.0 2.55 2.0 3.81 2.0 34.3
2.2 3.09 2.2 4.61 2.2 41.5
2.4 3.68 2.4 5.49 2.4 49.4
2.6 4.31 2.6 6.44 2.6 58.0
2.8 5.00 2.8 7.47 2.8 67.3
3.0 5.74 3.0 8.58 3.0 77.2

DC Inverter Package R32 Duct Type Unit
8
Ceiling type
Wall mounted type
Floor standing type
Weight(kg) Area (m2) Weight(kg) Area (m2) Weight (kg) Area (m2)
3.2 6.54 3.2 9.76 3.2 87.9
3.4 7.38 3.4 11.0 3.4 99.2
3.6 8.27 3.6 12.4 3.6 111
3.8 9.22 3.8 13.8 3.8 124
4.0 10.2 4.0 15.3 4.0 137
4.2 11.3 4.2 16.8 4.2 151
4.4 12.4 4.4 18.5 4.4 166
4.6 13.5 4.6 20.2 4.6 182
4.8
14.7
4.8
22.0
4.8
198
5.0 16.0 5.0 23.8 5.0 215
5.2 17.3 5.2 25.8 5.2 232
5.4 18.6 5.4 27.8 5.4 250
5.6 20.0 5.6 29.9 5.6 269
5.8 21.5 5.8 32.1 5.8 289
6.0 23.0 6.0 34.3 6.0 309
6.2 24.5 6.2 36.6 6.2 330
6.4 26.1 6.4 39.1 6.4 351
6.6 27.8 6.6 41.5 6.6 374
6.8
29.5
6.8
44.1
6.8
397
7.0 31.3 7.0 46.7 7.0 420
7.2 33.1 7.2 49.4 7.2 445
7.4 34.9 7.4 52.2 7.4 470
7.6 36.9 7.6 55.1 7.6 496
7.8 38.8 7.8 58.0 7.8 522
8.0 40.8 8.0 61.0 8.0 549
(2) When installing an outdoor unit with single or double fans, hold the handle
and then lift it up slowly (Do not touch the condenser with your hand or
other objects). If you hold only one side of the casing, the casing may be
pulled out of shape, so please hold the base of the unit as well. During
installation, be sure to use the components specified in the instruction
manual.
(3) Please use the charging machine specialized for R32 refrigerant; before
charging, keep the refrigerant tank in an upright position. After charging,

DC Inverter Package R32 Duct Type Unit
9
stick a label on the air conditioner saying no excessive charging.
(4) The following tools will be used: 1) Liquid-level gauge; 2) Screwdriver; 3)
Electric driven rotary hammer; 4) Drill; 5) Pipe expander; 6) Torque
wrench; 7) Open-end wrench; 8) Pipe cutter; 9) Leak detector; 10)
Vacuum pump; 11) Pressure gauge; 12) Universal meter; 13) Hexagon
wrench; 14) Tapeline.
3.1.2 Selection of Installation Location
WARNING
!
(1) If the outdoor unit will be exposed in strong wind, it must be securely located,
otherwise it may fall down.
(2) Install the air conditioner at a place where the inclination is less than 5°.
(3) Do not install the unit at a place with direct sunlight.
(4) Do not install the unit at a place with leakage of inflammable gas.
Selection of Installation Location for Indoor Unit (Select a location
pursuant to the following condition).
(1) Air inlet and outlet of the indoor unit should be away from obstacles to
make sure the unit’s air flow can reach the entire room. Do not install the
unit in a kitchen or a laundry.
(2) Install the unit in a room without naked flame, fire source or the risk of
getting the refrigerant on fire.
(3) Select a location that can withstand 4 times the unit weight without
increasing operating noise and vibration.
(4) The installation location must be level.
(5) The indoor piping length and wiring length should be within the allowable
range.
(6) Select a place that can easily drain condensate and connect to the drain
system of the air conditioner.
(7) If hoisting screw bolts are to be used, check whether the installation
location is safe enough. If not safe, reinforce the location before
installation.
(8) Indoor unit, power cord, connecting wires and communication cords
should be at least 1m from television and radio. This is to prevent image

DC Inverter Package R32 Duct Type Unit
10
interference or noise (Even at a distance of 1m, a very strong electric
wave may still generate noise).
Selection of Installation Location for Outdoor Unit (Select a location
pursuant to the following condition).
(1) Noise and air flow produced by the outdoor unit will not disturb the
neighbors.
(2) Select a location that is safe and away from animals and plants. If not,
please add safety fences to protect the unit.
(3) Install at a place with good ventilation. Make sure the outdoor unit stays at
a well-ventilated place with no obstacles nearby that may obstruct the air
inlet and outlet.
(4) The installation location should be able to withstand the weight and
vibration of outdoor unit and allow the installation to be carried out safely.
(5) Avoid installing at a place with leakage of inflammable gas, oil smoke or
corrosive gas.
(6) Keep it away from strong wind because strong wind will affect the outdoor
fan and lead to insufficient air flow volume and thus affecting the unit’s
performance.
(7) Install the outdoor unit at a place that is convenient for it to be connected
to the indoor unit.
(8) Away from any object that may get the air conditioner generating noise.
(9) Install the outdoor unit at a place where condensate can be easily
drained.
3.1.3 Unit Dimension
WARNING
!
(1) Install the indoor unit in a location which can withstand a load of at least five
times the weight of the main unit and which will not amplify sound or vibration.
(2) If the installation location is not strong enough, the indoor unit may fall and
cause injuries.
(3) If the job is done with the panel frame only, there is a risk that the unit will come
loose. Please take care.

DC Inverter Package R32 Duct Type Unit
11
(1) Indoor unit
ADG ECO 35PH,ADG ECO 50PH,ADG ECO 70PH
ADG ECO 85 PH,ADG ECO 100PH-T, ADG ECO 140PH, ADG ECO 160PH
Gas pipe
Liquid pipe
C
G
D
E
F
Electric Box
Drain pipe
A
B
ADG ECO 70PH, ADG ECO 70PHB, ADG ECO 85PH, ADG ECO 85PHB

DC Inverter Package R32 Duct Type Unit
12
NOTE!
Drilling of ceiling opening and installation of air conditioner must be performed by
professionals!
Unit: mm
Dimensions
Model
A B C D E F G
760 415 700 200 450 474 768
ADG ECO 35PH
1060 415 1000 200 450 474 1068
ADG ECO 50PH
1360 415 1300 220 450 474 1368
ADG ECO 70PH
ADG ECO 85PH
942 530 900 260 655 685 —
ADG ECO 70PHB
ADG ECO 85PHB
1040 500 1000 300 700 754 1092
ADG ECO 100PH
1440 500 1400 300 700 754 1492
ADG ECO 140PH
1440 500 1400 300 700 754 1543
ADG ECO 160PH

DC Inverter Package R32 Duct Type Unit
13
(2) Outdoor unit.
AEG ECO 35 PIH, AEG ECO 50PIH, AEG ECO 50PIH, AEG ECO 85PIH.
A
F
D
E
G
C
B
AEG ECO 100PIH, AEG ECO 140PIH, AEG ECO 100PIH3, AEG ECO 140PIH3
A
B
C
D
E
G

DC Inverter Package R32 Duct Type Unit
14
AEG ECO 160PIH3.
Unit: mm
Dimensions
Model
A B C D E F G
AEG ECO 35PH
818
378
596
550
348
887
302
AEG ECO 50PIH 818 378 596 550 348 887 302
AEG ECO 70PIH 892 396 698 560 364 952 340
AEG ECO 85PH
920
427
790
610
395
1002
370
AEG ECO 100PIH 940 530 820 610 486
—
460
AEG ECO 100PIH3 940 530 820 610 486
—
460
AEG ECO 140PIH 940 530 820 610 486
—
460
AEG ECO 140PIH3 940 530 820 610 486
460
AEG ECO 160PIH3900 412 1345 572 378 —340
—

DC Inverter Package R32 Duct Type Unit
15
3.1.4 Diagram of Unit Installation Space and Location
(1) Diagram of installation space and location for outdoor unit (Notice: for best
performance of the outdoor unit, make sure its installation space
conforms to the following installation dimensions).
1) When one outdoor unit is to be installed.
A~E HbHdH (mm)
a
b
c
d
e
B
—
—
≥100
—
—
—
A,B,C, — ≥300 ≥100 ≥100 — —
B,E — — ≥100 — — ≥1000
A,B,C,E
—
≥300
≥150
≥150
—
≥1000
D
—
—
—
—
≥1000
—
D,E — — — — ≥1000 ≥1000
B,D
H
b<
H
d
H
d>
H
—
≥100
—
≥1000
—
H
b>
H
d
H
d<
H
—
≥100
—
≥1000
—
B,D,E
Hb<Hd
Hb≤1/2H — ≥250 — ≥2000 ≥1000
1/2H<Hb≤H
— ≥250 — ≥2000 ≥1000
H
b>
H
Prohibited
Hb>Hd
Hd≤1/2H — ≥100 — ≥2000 ≥1000
1/2H<Hd≤H
— ≥200 — ≥2000 ≥1000
H
d>
1/2H
Prohibited

DC Inverter Package R32 Duct Type Unit
16
2) When two or more outdoor units are to be installed side by side.
Unit: mm
A~E HbHdH
(mm)
a b c d e
A,B,C — ≥300 ≥300 ≥1000 — —
A,B,C,E — ≥300 ≥300 ≥1000 — ≥1000
D — — — — ≥2000 —
D,E — — — — ≥2000 ≥1000
B,D
Hb<HdHd>H — ≥300 — ≥2000 —
Hb>HdHd≤1/2H — ≥250 — ≥2000 —
1/2H<Hd≤H — ≥300 — ≥2500 —
B,D,E
Hb<Hd
Hb≤1/2H — ≥300 — ≥2000 ≥1000
1/2H<Hb≤H — ≥300 — ≥2500 ≥1000
Hb>H Prohibited
Hb>Hd
Hd≤1/2H — ≥250 — ≥2500 ≥1000
1/ H<Hd≤H — ≥300 — ≥2500 ≥1000
Hd>1/2H Prohibited
This manual suits for next models
17
Table of contents
Other Argo Air Conditioner manuals

Argo
Argo SWAN EVO User manual

Argo
Argo X3I ECO PLUS 35 SH LHB Operating manual

Argo
Argo Misse13DCI User manual

Argo
Argo POLIFEMO BILLY User manual

Argo
Argo ARGO 245C User manual

Argo
Argo ULISSE ECO User manual

Argo
Argo CHARM Series User manual

Argo
Argo Holly User manual

Argo
Argo XFETTO DCI HPL User manual

Argo
Argo MAXIME PLUS EU User manual
Popular Air Conditioner manuals by other brands

LG
LG ARUN50GS2A Quick manual

LG
LG ABUQ18GM1T0 installation manual

Ingersoll-Rand
Ingersoll-Rand 4TVE0007B100NC Installation, operation and maintenance

SCE
SCE Enviro-Therm SCE-AC8500B460V user manual

Royal Sovereign International
Royal Sovereign International ARP-908 owner's manual

Daikin
Daikin FTXG25CVMBW Operation manual