manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Argweld
  6. •
  7. Welding Accessories
  8. •
  9. Argweld PURGEYE 200 User manual

Argweld PURGEYE 200 User manual

Other Argweld Welding Accessories manuals

Argweld PurgExtra User manual

Argweld

Argweld PurgExtra User manual

Argweld Multi Exhaust User manual

Argweld

Argweld Multi Exhaust User manual

Popular Welding Accessories manuals by other brands

RelFar FWH20-S10A manual

RelFar

RelFar FWH20-S10A manual

Lincoln Electric LT-7 Tractor Technical specifications

Lincoln Electric

Lincoln Electric LT-7 Tractor Technical specifications

Cornwell Tools MMWC1 Operator's manual

Cornwell Tools

Cornwell Tools MMWC1 Operator's manual

Dohle ExOn2A operating instructions

Dohle

Dohle ExOn2A operating instructions

Nederman Fume Eliminator FE 840/2500/P150 user manual

Nederman

Nederman Fume Eliminator FE 840/2500/P150 user manual

3M Speedglas 9100 Series user manual

3M

3M Speedglas 9100 Series user manual

Miller Electric OM-842 owner's manual

Miller Electric

Miller Electric OM-842 owner's manual

Miller A-200 Series owner's manual

Miller

Miller A-200 Series owner's manual

Abicor Binzel ABIMIG WT Series operating instructions

Abicor Binzel

Abicor Binzel ABIMIG WT Series operating instructions

Miller MIGmatic M-25 owner's manual

Miller

Miller MIGmatic M-25 owner's manual

Abicor Binzel xFUME PRO Original operating instructions

Abicor Binzel

Abicor Binzel xFUME PRO Original operating instructions

iWeld NORED EYE user manual

iWeld

iWeld NORED EYE user manual

Sthor 74483 manual

Sthor

Sthor 74483 manual

Miller I-22 CE owner's manual

Miller

Miller I-22 CE owner's manual

LAHTI PRO L1540400 instruction manual

LAHTI PRO

LAHTI PRO L1540400 instruction manual

Lincoln Electric K3091-1 Operator's manual

Lincoln Electric

Lincoln Electric K3091-1 Operator's manual

Miller Electric A1D-4RV owner's manual

Miller Electric

Miller Electric A1D-4RV owner's manual

Tregaskiss TOUGH GUN TT3 Reamer owner's manual

Tregaskiss

Tregaskiss TOUGH GUN TT3 Reamer owner's manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

YOUR WELDING SOLUTION PROVIDER.
1300 728 422
www.smenco.com.au
YOUR WELDING SOLUTION PROVIDER.
ARGWELD®
PURGEYE®200
WELD PURGE
MONITOR®
NEW
Rechargeable
battery powered
measuring down
to 10 ppm
NEW, PurgEye®200 Rechargeable Battery Driven
Weld Purge Monitor
Now an important addition to the PurgEye®Family
of Weld Purge Monitors®. This PurgEye®200 hand
held model reads very accurately down to 10 parts
per million (ppm). This low cost unit has made several
breakthroughs in design and development technology
in weld purge monitoring.
Being rechargeable battery operated and hand held,
this is an excellent model for use on construction sites
where high purity tubing or pipe is being welded. The
PurgEye®Family Range of Weld Purge Monitors®
have become the standard instrument of today,
recognised and used by most companies who need to
produce quality control weld joints.
PurgEye®, a Family Series of Weld Purge Monitors®,
helping customers to keep your ‘Eye’ on the Purge!
FEATURES
Electro-mechanical internal pump with 1 l/m
flow rate
Multi-Function power (power, standby,
mute, pump)
Auto power-off after 15 mins, automatic sleep
mode when not in use
Accurate readings from 1000 to 10 ppm
Rechargeable battery operated
Hand held easy to use instrument
Safety lanyard for wrist and neck
Alarm mute where desired
Large character LCD Display for easy reading
Flow detection for accurate reading of
gas samples
Power on / off with Standby Button for
sensor warm up
Alarm + and - buttons for displaying
threshold settings
Quick connect / disconnect exhausting
gas hose connections
Warning alarm levels between 1 and 999 ppm
Low battery indicator
YOUR WELDING SOLUTION PROVIDER.
1300 728 422
www.smenco.com.au
YOUR WELDING SOLUTION PROVIDER.
Auto Power-Off
If the PurgEye® 200 is left with an over-range reading for more than 15 minutes, then it will automatically turn off
to conserve battery power.
Warning Alarm
The Warning Alarm can be set to any level between 1 and 999 ppm and has both audible and visual indication
when the alarm threshold is exceeded.
Flow Detection
The flow warning exclamation icon will be displayed when ever the flow of sample gas drops below the minimum
flow rate required for an accurate reading. Please note, this could be due to a blocked filter in need of replacement.
Large Character LCD Display
The large LCD display allows the reading to be easily read and helps conserve battery power compared to other
display technologies.
Power On / Off
If the PurgEye®200 is off, then pressing the Standby button will switch it on and it will start the sensor warmup
procedure. The PurgEye®200 can be turned off by holding the Standby button for approx. 10 seconds or
until it turns off.
Intergral Sample Pump
With the PurgEye®200 switched on and the alarm inactive or muted, pressing the Standby button will turn
the intergral sample pump on and off.
Alarm Mute
If the alarm is sounding, then pressing the Standby button will mute the alarm, subsequent presses will control the
sample pump.
Alarm + and Alarm - Buttons
Pressing either of the alarm buttons will display the current alarm threshold setting. When the alarm threshold is
displayed, the first digit will flash, pressing either of the alarm buttons at this point will increase or decrease the
value of the flashing digit.
YOUR WELDING SOLUTION PROVIDER.
1300 728 422
www.smenco.com.au
YOUR WELDING SOLUTION PROVIDER.
GUARANTEED ACCURANCY
The PurgEye®200 Weld Purge Monitor® indicates oxygen levels from 1000 down to 10 ppm (0.001%), so use
an Argweld® PurgEye®Weld Purge Monitor® everytime for guaranteed accuracy of oxygen indication to allow a
weld start with minimal risk of oxidation.
Low Battery Indicator
When the Low Battery Icon appears, the user should swap to the fully charged battery set. From
the time the indicator appears, there should be 10 to 20 minutes working time remaining.
Warming up
The Wait Icon indicates when the PurgEye®200 is warming up and not yet ready to give a reading.
During the warming up procedure , the progress will be indicated by either 1, 2, 3 or 4 flashing bars
across the display.
Alarm Icon
The Alarm Icon will indicate when the display is showing the alarm thershold rather than the current
reading, it will also flash when the current reading exceeds the alarm threshold.
Blocked Filter
The Alert Icon, indicates when there is insufficient flow of purge gas which could be caused by a
blocked filter.