6. If you need to adjust the settings during the heating mode, you could repeat step
2 to step 5 to do the adjustment.
7. When the heat platen has settled into its desired temperature, press down the
heat platen, then the timer will automatically start counting down and CD-L indicator
blinks. The timer will begin to sound once it reaches 3 seconds. The warning is meant
to prepare the user to release the handle once the time reaches 0 seconds. When
the handle is lifted, the timer will automatically sound off.
8. Long press the digital controller for 4-5 seconds, then can enter the engineering
model:
P-5: Temperature Difference Calibration Mode, calibration range is -99 to +99
P-6: Intermittent heating in advance before setting, setting range is from 1 to 20 Sec.
This function is to set the heating time and pause time after the machine enter the
constant temperature mode. The setting parameters is different according to
different size of heat platen.
P-7: Constant temperature in advance before setting, setting range is from 1 to 9
degree.
This function is to set when the machine will enter the constant temperature mode.
You could set a temperature value that you want to enter to constant temperature
before it reach the setting temperature.
For example, the setting temperature is 180℃and P-7 is 10℃, then when the
temperature reaches 170℃, it will enter the constant temperature mode, heating
and pause in cycle to avoid overheat.
P-8: Constant temperature mode, when reach the setting temperature, the machine
will stop heating for 1 seconds then will keep heating for few seconds, setting range
is from 0 to 9 Sec.
P-9: Countdown mode: “No”means when the machine work, it will count down,
“Yes”means when reach the setting temperature, the machine will enter the
countdown mode.