Service&Maintenance
Once amonth: Press thetestbutton
to trigger thedetector. Note, putting
thealarmpanel inprogramming mode,
will preventthealarmsirens from
triggering as well.
Every6months: Vacuumor blow
dustoutofthedetector tohelp reduce
falsealarms.
500mm 500mm
SLOPEDROOF
Min.
200mm
Operation&Testing
During NormalOperationtheLEDflashes
every45seconds.
Pressing theTest Buttonwill activatetest
mode, triggering boththeRelayand the
Buzzer.
Thesmokealarm will automaticallyreset
whenall thesmokehascleared.
Hushfeature. Whilst thesmokedetectoris
inactivated, pressing thetest buttonfor1
second, will silencethat smokedetectors
sounder. This will not hushthe controllers
sounders or othersmokedetectors connected
ARROWHEADALARM PRODUCTSLtd.
1AEmirali Road,
Silverdale0932
AUCKLAND
Ph. 09414 0085
www.aap.co.nz
v2.02
HM-SMOKE
AUTORESETTING SMOKEDETECTOR
WithPower Monitoring
Specifications
DetectionTypePhotoelectric Chamber
PowerSource9-16 VoltsDC
StandbyCurrent25mA
Alarm Current20mA
BuzzerOutput85db @3meters
Output RelayN/Oand N/CContacts
100mA max
DimensionsØ100mm x55mm
Standards:GB4715-2005,EN14604, UL217
SuggestedMounting Locations
Smokealarms mustbelocated inescaperouteson
all levels withinthehousehold unit.
Onlevels containing sleeping spaces, theymustbe
installed withinthesleepingspace, or within
3metres ofeverysleepingspacedoor. And they
mustbeaudiblethroughclosed doors.
Always Refer to NZS 4514:2009or thelatest
standard for full installationrecommendations.
=MOUNTING AREA
=DON’T FITAREA
(DEADAIRSPACE)
Max. 300mm
CEILING
WALL
BEST
LOCATION
ACCEPTABLE
LOCATION
Note. SmokeDetectors should be
mounted aminimumof400mm away
fromAir Con. or forced air vents.
Testat leastonceamonth.
Min.
100mm
Min.
200mm
900mm
or less
Beams,joists and
exposed rafters
deeper than
460mm are
treated as walls
Min.
200mm
Always Refer to NZS 4514:2009or thelatest
standard for full installationrecommendations.