asecos S Series User manual

EN
Years5
Warranty*
EP.V.34171.00 | 04/2023
USER MANUAL
Safety storage cabinets according to EN14470-1
5 YEARS WARRANTY
Upon conclusion of an asecos service
and maintenance agreement (BasicPlus
tari ) with a fixed term of 5 years, you
will get a warranty extension for a
maximum of 5 years for your safety
storage cabinet.
For detailed information about our
warranties please visit:

XL90.222.155.WDAS XL90.222.110.WDASK30.197.120.MV.FWAS
K30.197.120.MC.FWAS
K90.196.120.MF.FWAS
K90.196.120.MC.FWAS
K90.196.120.MF.FWAC
K90.196.120.MC.FWAC
S90.196.120.FDAO S90.196.060.FDAO
S90.196.060.075.FDAO
S90.196.120.FDAS
S90.196.120.MV.FDAS
S90.196.090.FWAS
S90.196.060.FDAS
S90.196.060.FDASR
S90.196.060.MH.FDAS
S90.196.060.MH.FDASR
S90.196.060.075.FDAS
S90.196.060.075.FDASR
S90.196.120.FDAC
S90.196.120.MV.FDAC
S90.196.060.FDAC
S90.196.060.FDACR
S90.196.060.075.FDAC
S90.196.060.075.FDACR
S90.129.120.WDAC S90.129.060.WDAC
S90.129.060.WDACR
S90.196.120
S90.196.120.WDAS
S90.196.120.MV.WDAS
S90.196.090
S90.196.090.WDAS
S90.196.060
S90.196.060.WDAS
S90.196.060.R
S90.196.060.WDASR
S90.196.060.MH.WDAS
S90.196.060.MH.WDASR
S90.196.060.075.WDAS
S90.196.060.075.WDASR
S90.129.120
S90.129.120.WDAS
S90.129.060
S90.129.060.WDAS
S90.129.060.R
S90.129.060.WDASR
S-CLASSIC-90
S-PEGASUS-90 S-PHOENIX-90
S-PHOENIX Vol.2-90 S-PHOENIX touchless-90
K-PHOENIX-30 K-PHOENIX-90 K-PHOENIX Vol.2-90 XL-CLASSIC-90

Contact
Company
Street
Name of contact person
email
Serial numbers of safety storage cabinets
Phone No.
Postal code Town
YOUR PERSONAL DOCUMENTATION TO THE asecos
SAFETY CABINET
Dear Customer,
you have made a decisive investment in safety for your company by purchasing this asecos safety
storage cabinet. You now own an innovative product made of top-quality materials guaranteeing
the highest quality standards.
asecos safety storage cabinets have complete authorisation documents. We archive the authori-
sation documents for every individual cabinet, keeping them ready for you should you ever need
them (e.g. for a works inspection or similar). Simply request them using this form.
Tear of or copy that page and return to us by fax with your address and serial number of the
cabinet on it.
Yours sincerely
asecos GmbH
asecos GmbH
Customer service
Weiherfeldsiedlung 16–18
D-63584 Gründau
Fax: +49 60 51 - 92 20-10
email: service asecos.com

4
EN OPERATING INSTRUCTIONS
Dear customer,
Thank you very much for purchasing a safety storage cabinet from our company, with which you have made
a decisive investment in the safety within your company. Our safety storage cabinets make the storage of
hazardous materials at the workplace safe and convenient for you.
Please read these operating instructions very carefully. Get to know the advantages and simple operability of
our safety storage cabinets in detail. This simplifies the daily handling of hazardous materials for you.
Many thanks
Your asecos team
1. NOTES • GUIDELINES • GUARANTEE ...........................................5
1.1. General safety notes ............................................... 5
1.2. Guarantee........................................................ 5
1.3. Cabinet Details.................................................... 5
1.4. Marking and symbols on the cabinet .................................. 6
2. TRANSPORT ...............................................................6
2.1. General facts ..................................................... 6
2.2. Tilting the cabinet ................................................. 6
3. ERECTION • COMMISSIONING • FUNCTION......................................7
3.1. Alignment Of The Cabinets .......................................... 7
3.2. Commissioning.................................................... 8
3.3. Connection to the power supply ...................................... 8
3.4. Anti-Tilt Device .................................................... 8
4. OPENING AND CLOSING MECHANISMS ........................................9
4.1. Opening the cabinet ............................................... 9
4.2. Closing the cabinet ................................................ 9
4.3. Locking ......................................................... 10
4.4. Automatic door closing system (TSA) ................................. 10
4.5. Automatic door closing system (Sensor). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
5. INTERIOR FITTINGS ........................................................11
5.1. Bottom collecting sump.............................................11
5.2. Perforated insert ................................................. 12
5.3. Shelves (height-adjustable) ......................................... 12
5.4. Shelf (permanently mounted)....................................... 12
5.5. Tray shelves (height-adjustable) ..................................... 12
5.6. Metal free tray shelves............................................. 12
5.7. Grid shelves (height adjustable) ..................................... 13
5.8. Drawers ........................................................ 13
5.9. Pull-out shelves (Models K-LINE) .................................... 15
5.10. Storage box...................................................... 15
5.11. Rack system for XL-LINE............................................ 15
5.12. Leak s .......................................................... 16
6. STORAGE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
6.1. Fire-protected lead-through......................................... 16
7. EARTHING................................................................16
7.1. Ground connection ............................................... 17
7.2. Grounding PREMIUM .............................................. 17
7.3. Grounding the interior ............................................. 18
8. VENTILATION .............................................................18
8.1. Fire protection valves XL-LINE ....................................... 18
9. FIRE • DISPOSAL. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18
9.1. Opening the cabinet after the fire .................................... 19
9.2. Disposal ........................................................ 19
10. SAFETY CHECKS ...........................................................19
10.1. In general ....................................................... 19
10.2. Wearing parts .................................................... 19
11. TECHNICAL DRAWING......................................................20
12. TECHNICAL DATA ..........................................................21
12.1. Table with technical data ........................................... 21
12.2. Table with storage capacities........................................ 22

5
EN
1. NOTES • GUIDELINES • GUARANTEE
1.1. GENERAL SAFETY NOTES
• Observe applicable statutes and regulations, and the notes in these operating instructions, when handling
hazardous materials
• Work on the electrical system is to be carried out only with the power turned o and only byqualified electri-
cians – refer here to the regulations of the local electricity supply company.
• The on-site installation conditions are to be observed (e.g. bolting the cabinets to the building).
• The instructions of the supervisory engineering department must be followed.
• Observe accident prevention regulations and workplace ordinance
• Ensure that the necessary safety checks are only carried out by authorised sta using original
spare parts
• Only use the cabinet after having been properly instructed; access is to be forbidden to unauthorised persons.
• The pivoting area of the doors is to be kept free at all times; doors/drawers are to be kept closed
• By assigning trained/authorised technical personnel you can prevent the malfunctions, damage and corrosion
damage that result from inappropriate transport.
• Observe the upper limits for stored quantities, loading etc.
• Containers with a volume larger than that of the bottom collecting sump may not be placed inside the cabi-
net; spilt hazardous materials are to be collected immediately and removed
• Vessels containing aggressive chemicals (acids and alkalis) are to be kept in special cabinets for acids and
alkalis or on shelves for acids and alkalis
• To avoid explosive atmospheres and harmful vapours, sucient technical ventilation is strongly recommended.
Please observe the instructions for connection to an exhaust air system.
• Before storing such materials, check that the cabinet’s surface is resistant to the chemicals.
• Before the initial commissioning, the safety storage cabinet is to be examined by the user for possible dam-
age.
Set-up requirements
0–35 °C 30–70 %
1.2. GUARANTEE
The guarantee for this product is agreed between you (the customer) and your dealer (the seller). As the
manufacturer, asecos guarantees the products listed in the operating instructions for a period of 24 months
from the date of delivery. All model safety equipment are subject to a compulsory annual inspection by spe-
cialised sta authorised by the manufacturer. Otherwise the customer’s guarantee claim against the manufac-
turer expires.
1.3. CABINET DETAILS
A complete overview of the models can be found at the start of the operating instructions.
Cabinet data: logbook (included with the cabinet)
Technical drawing: see appenidix
Technical data: table in appendix
S-LINE and XL-LINE
All cabinets are used for the safe, passive storage of flammable liquids in work rooms in accordance with
applicable national regulations. The models are tested, certified and marked according to the requirements of
EN14470-1.
K-LINE
The left compartments of the cabinets are used for the safe, passive storage of flammable liquids in work
rooms in accordance with applicable national regulations and are tested, certified and marked in accordance
with the requirements of EN 14470-1. The right compartments of the cabinets are used for the separate
storage of aggressive, non-flammable hazardous substances (e.g. acids and alkalis
Model versions .MH/.MV:
Cabinet interior with vertical or vertical and horizontal partition. Enables the separate storage of hazardous
substances in a safety cabinet in two or four compartments. Please note: the separate storage of dier-
ent hazardous substances in the safety cabinet takes place without taking into account other fire protection
requirements.

6
EN 1.4. MARKING AND SYMBOLS ON THE CABINET
Various stickers with dierent symbols are attached to the cabinet. An explanation of the individual symbols
and illustrations is provided below.
1Prohibition sign: No open
flame 2Mandatory sign: Refer to
instruction manual/booklet 3Mandatory sign: Keep doors
closed 4Recommendation: Connection
to a technical ventilation
system is recommended.
5Load is prohibited: No addi-
tional cabinet may be placed
on the cabinet ceiling.
6Load permitted: An additional
cabinet may be placed on
the cabinet ceiling.
7On the left-hand door:
opening and closing direction
for turning the key.
8On the right-hand door:
opening and closing direction
for turning the key.
2. TRANSPORT
2.1. GENERAL FACTS
CAUTION:
Transport the cabinet in an upright position on a pallet truck, tied and secured against slipping, until the
final place of installation is reached.The transport locks in the door joints may only be removed directly
at the place of installation! Inappropriate transport can lead to concealed damage to the fire protection
insulation!We can only guarantee the necessary quality if the cabinet is transported to the place of its use
by our specially trained sta.
2.2. TILTING THE CABINET
CAUTION:
Tilting the cabinet may only be done without jolts!
ATTENTION XL-LINE
XL-LINE cabinets may only be transported standing up. It is forbidden to tilt the cabinet!

7
EN
3. ERECTION • COMMISSIONING • FUNCTION
3.1. ALIGNMENT OF THE CABINETS
CAUTION:
Door elements must not scrape against the fire prevention seals in the fold of the door when opening and
closing! Doors with an automatic closing mechanism must close automatically from every position and the
lock must be able to lock!
NOTE
If the distance between door and floor is greater than 40 mm and less than 120 mm, appropriate door
panels can be used to avoid possible crushing hazards in the foot area. The matching panels for the cabinet
model can be requested free of charge at service@asecos.com.
S-LINE
K-LINE
S-PHOENIX touchless-90
1
1Unlock the cabinet and open it manually
2Remove the power cable from the interior
3Align the cabinet
4Allow the cabinet to close automatically
XL-LINE
made of
metal!

8
EN 3.2. COMMISSIONING
• Before putting into operation for the first time, the user must carry out an examination of the safety storage
cabinet for possible damage, such as defective or loose sealing elements, correct alignment and perfect func-
tioning of the door elements.
Use the cabinet and accessories only if they are in an orderly condition.
3.3. CONNECTION TO THE POWER SUPPLY
Accessories: 5 m low-temperature IEC power cable including earthed mains plug
S-PHOENIX touchless-90
3.4. ANTITILT DEVICE
xx
CAUTION
If the cabinets are equipped with more than 6 drawers or more than one heavy-duty drawer, they must be
securely attached to the building wall using the tilt protection provided. Depending on the nature of the wall,
suitable fastening material, which may dier from the scope of delivery, must be selected

9
EN
4. OPENING AND CLOSING MECHANISMS
4.1. OPENING THE CABINET
123
1Manual opening of the
individual doors
2For two-door cabinets:
Manual opening of both
doors with only one hand.
The cabinet is equipped
with AGT.
3Automatic opening of the
door by means of sensors.
S-LINE
SCL A SSIC9 0 3
with door version WDAS 3
SPEGASUS90 3 3
SPHOENIX90 3
SPHOENIX Vol.290 3 3
SPHOENIX touchless90 3
K-LINE
KPHOENIX30
Left compartment 3
Right compartment 3
KPHOENIX90
Left compartment 3
Right compartment 3
KPHOENIX Vol.290
Left compartment 3
Right compartment 3
XL-LINE
X LC L AS SI C9 0 3
4.2. CLOSING THE CABINET
12345
S-LINE A B
SCL A SSIC9 0 3 3
with door version WDAS 3 3 3
SPEGASUS90 3 3 3 3
SPHOENIX90 3 3 3
SPHOENIX Vol.290 3 3 3 3
SPHOENIX touchless90 3 3
K-LINE
KPHOENIX30
Left compartment 3 3 3
Right compartment 3 3 3
KPHOENIX90
Left compartment 3 3 3
Right compartment 3
KPHOENIX Vol.290
Left compartment 3 3 3 3
Right compartment 3
XL-LINE
X LC L AS SI C9 0 3 3 3
1Doors closable only by hand
2Doors permanently self-closing or self-closing after release
of the doors from the arresting system
3Automatic door closing
AAutomatic door closing system TSA
BBy sensor detection
Other features
4Doors with open-arrest system
5Thermal release: in the case of fire the doors close
automatically

10
EN 4.3. LOCKING
12
S-LINE
SCL A SSIC9 0 3
SPEGASUS90 3
SPHOENIX90 3
SPHOENIX Vol.290 3
SPHOENIX touchless90 3
K-LINE
KPHOENIX30
Left compartment 3
Right compartment 3
KPHOENIX90
Left compartment 3
Right compartment 3
KPHOENIX Vol.290
Left compartment 3
Right compartment 3
XL-LINE
X LC L AS SI C9 0 3
1Safety cylinder
2CYLINDER LOCK (suitable for master key systems)
ATTENTION:
The owner/user must ensure that all doors are kept closed whenever the contents of the cabinet are
not being accessed. In general, it must be noted that the cabinets do not possess an emergency unlocking
facility. This means that persons trapped inside the cabinet cannot free themselves!
4.4. AUTOMATIC DOOR CLOSING SYSTEM TSA
CAUTION:
The doors close automatically. The time interval until the doors close can be set individually by means of a
jumper (preset: 60 seconds). Do not push the doors to close by hand, since this can lead to damage to the
mechanism!
Sequence
Changing the closing times with the aid of the jumper
1: 15 sec
2: 60 sec
3: 4.5 min 3
CAUTION:
The electrical cable on the housing may not come into contact with the locking linkage of the cabinet!

11
EN
Battery replacement
3
=4×
4
=4× 5
=4× 6
4.5. AUTOMATIC DOOR CLOSING SYSTEM SENSOR
S-PHOENIX touchless-90
Entering the sensor range during the closing movement
CAUTION:
The closing of the doors takes place purely mechanically and only with the very low forces of the closing
spring. Reaching inside the cabinet during the closing process is therefore harmless and the risk of injury is
ruled out.
5. INTERIOR FITTINGS
CAUTION:
Loose parts (e.g. insertable sumps) must always be fully installed/inserted in order to ensure secure closing
of the cabinet doors in case of fire.
5.1. BOTTOM COLLECTING SUMP
11
22
According to EN 14470-1: The bottom collecting sump must be
able to hold a minimum volume of 10 %of all the containers stored
in the cabinet [1] or at least 110 %of the volume of the largest single
container [2] , whichever of these volumes is larger.

12
EN 5.2. PERFORATED INSERT
8
8
44
For use as a storage level in the bottom collecting sump
5.3. SHELVES HEIGHTADJUSTABLE
S-LINE
K-LINE (left compartment)
5.4. SHELF PERMANENTLY MOUNTED
XL-LINE
ca. 50 cm
• The installation of the shelf is done at the factory in a fixed position.
• The assembly is carried out with additional support brackets on the side
walls and the rear wall.
• The cabinets have no grid holes on the side walls and the rear wall.
• If a position other than the factory-set position is required on site, the
support brackets must be repositioned at the desired height and then
screwed again accordingly.
5.5. TRAY SHELVES HEIGHTADJUSTABLE
S-LINE
K-LINE (left compartment)
4
5
5.6. METAL FREE TRAY SHELVES
Applies to cabinet models S-LINE and K-LINE type 30 (compartment on the right, for flammable liquids)
• Suitable for storing small quantities of flammable, slightly aggressive hazardous substances
• The tray shelf is installed in the cabinet in fixed positions by the manufacturer. The PP plastic sump is placed
on the shelf and secured against pulling out.
CAUTION:
The height of metal-free tray shelves in safety storage cabinets may only be adjusted on site by authorized
asecos employees, as further pre-assembly work is necessary for this!

13
EN
5.7. GRID SHELVES HEIGHT ADJUSTABLE
S-LINE
1
2
3
4
5
6
789
5.8. DRAWERS
S-LINE models with carcase width 120 or 90 cm (version without dividing wall)
Before first use and loading, the bottom drawer must be additionally secured against unintentional removal.
Securing the lowest drawer
against possible lifting out
123
4
CAUTION:
Depending on the number, the drawers are installed at the factory in fixed positions in the cabinet. Subject
to technical feasibility, special classifications are possible at an additional cost.

14
EN
2-door cabinet models S-LINE
• Standard operation: Pull the drawer out of the cabinet by hand and push it in again
• Event of fire: thermal release, pulled out drawer is automatically drawn into the cabinet
Normal operation
2
3
4
5
Event of fire
2
3
4
5
6
CAUTION:
When a second heavy-duty drawer has been installed, the cabinets have to be secured to the building wall
using the enclosed material to prevent them from tipping over. The choice of fasteners (dowels and screws)
may have to be adapted to the structural conditions on site if necessary.
1-door cabinet models S-LINE
2-door cabinet models K-LINE (left compartement, for flammable liquids)
• Standard operation: Pull the drawer out of the cabinet by hand. As soon as the drawer is released, it auto-
matically retracts back into the cabinet with a time delay.
23
4
CAUTION:
The height of the drawers in safety storage cabinets may be adjusted only by authorised asecos employees,
since the safe retraction of the drawers in case of fire must be guaranteed!

15
EN
5.9. PULLOUT SHELVES MODELS KLINE
Right compartment (for inflammable hazardous materials – acids and bases)
• Pull-out shelves are are permanently installed in the cabinet and have a pull-out protection.
• They have to be pushed into the cabinet by hand after us.
• Cabinets with pull-out shelves must be attached to the wall using an anti-tilt device (see 3.2)!
123
5.10. STORAGE BOX
Separately lockable, for the separate storage of small quantities of chemicals in the cabinet.
• The storage box must be placed on a shelf and is screwed to the side wall at the factory. The top shelf in the
cabinet is used as standard for installation.
2
= 4,5 mm
= 35 mm
3
4
4×
5
6
5.11. RACK SYSTEM FOR XLLINE
1
2
3
456
Q (+230 kg)
Q (+230 kg)
Q (+230 kg)
∑ Q (=920 kg)
Qmax.
(kg)

16
EN CAUTION:
Load capacity shelf (depth 600 and 800 mm) = 240 kg
Bay load (shelf depth 600 mm and 800 mm) = 1600 kg
The specified maximum load capacity for shelves [Q] apply to an evenly distributed load.
The sum of the compartment loads [ΣQ] in a shelf bay must be less than or equal to the specified bay load
[Qmax.].
5.12. LEAKS
PLEASE NOTE
Liquid in the bottom collecting sump / drawer and in the sump of pull-out tray, must be taken up immedi-
ately and using suitable means. The choice of the means is your own responsibility, depending on the
leaked chemical.
1
2
6. STORAGE
For passive storage of flammable liquids in work rooms (see point 1.3)
• Vessels containing aggressive chemicals (acids/alkalis) are to be kept in special cabinets for acids and alkalis
or on shelves for acids and alkalis.
CAUTION:
Stored corrosive liquids can impair the function
›of the shut-off devices for the supply and exhaust air
›of self-closing in the event of fire
6.1. FIREPROTECTED LEADTHROUGH
The optionally available fire protection lead-through enables pipelines, hoses and cables to be carried through
in compliance with the tested fire resistance of the safety cabinet.
Please do not hesitate to contact us for information on the permissible lead-through areas, maximum permis-
sible diameter of the cables and further information.
7. EARTHING
An earth connection may be necessary, depending on the customer-specific use of the safety storage
cabinet. The decision regarding this is taken on the basis of a risk analysis by the customer.
ABC
ARear section: XL-LINE
BTop section: K-PHOENIX-30
CTop section: S-LINE 90 minutes | K-LINE 90 minutes

17
EN
7.1. GROUND CONNECTION
All models have an earthing connection. The cabinet body (side and top panels) is metallically conductively
connected to each other via the earthing connection. The earthing connection is prepared for the creation of
the potential equalisation on site.
• XL-LINE: factory assembled
• K-LINE / S-LINE 90: is enclosed with the product and must be mounted on site at the appropriate location
on the headboard
A
B
B
B
B
C
C
D
D
E
F
G
F
Legende
A1 × screw M6×30
B4 × washer Ø 6,4
C2 × spring washer Ø 6,4
D2 × serrated lock washer Ø 6,4
E1 × nut with clamping part
Fearthing wire with ring cable lug (on-site
connection)
Gmetal part of the safety storage cabinet
7.2. GROUNDING PREMIUM
Only available in combination with cabinet for factory assembly.
Optionally, the wardrobes are equipped as follows for an additional charge:
S-LINE
Additional metallic conductive connection of the door panels, door handles and baseboard with the cabinet
body
• Models with hinged door(s): Article 39559 (HF.E.34091)
• Models with folding door(s): Article 39554 (HF.E.34090)
K-LINE
Additional metallic conductive connection of the door panels, door handles and baseboard with the cabinet
body
• All models: item 39554 (HF.E.34090)
XL-LINE
Additional metallic conductive connection of the door panels, baseboard and, if present, the transport plinth to
the cabinet carcass.
• All models: item 39617 (HF.E.34146)

18
EN 7.3. GROUNDING THE INTERIOR
Optionally, the cabinets can be equipped with an earthing connection for the interior fittings at an extra charge.
S-LINE
• Earthing lug inside with connection to the central earthing connection point on the cabinet ceiling.
• incl. one earthing lead incl. pick-up terminal - item 28056 (HF.E.11051)
• Additional earthing cable incl. tapping terminal for earthing another storage level - Article 33987 (HF.E.29665)
K-LINE
• Earthing lug in the left compartment inside with connection to the central earthing connection point on the
cabinet ceiling.
• incl. one earthing lead incl. pick-up terminal - item 28056 (HF.E.11051)
• Additional earthing cable incl. tapping terminal for earthing another storage level - Article 33987 (HF.E.29665)
XL-LINE
• The cabinets are equipped as standard with up to three earthing leads incl. tap terminal in the interior. The
earthing cables are factory-fitted at the earthing connection point on the rear wall of the cabinet.
8. VENTILATION
CAUTION
The fire protection valves near the supply and extraction air connections are safety and
maintenance-relevant components.
In order to check the correct operation or to replace a defective element, please ensure that flexible
connecting hoses or sliding pieces are used to connect to an extraction system in order to ensure simple
dismounting and re-mounting of the extraction air connection.
• If installed on an exhaust system, a check must be carried out to ensure proper connection to the system (e.g.
using a smoke tube)
• All models can be connected to a technical exhaust system via the exhaust connector. Please see the respec-
tively applicable national regulations for the specified air recirculation rate, maximum pressure losses and
exhaust air ducts.
DN
75
CAUTION:
In general these models can be operated without technical ventilation. The direct environment of
the cabinet can be an explosive zone in this case. If the cabinet is to be operated without an exhaust
connection, the user must attach a marking to it. With some models the supply and exhaust connectors are
not pre-mounted. They are included with the cabinet and must be screwed to the openings on the top
section.
8.1. FIRE PROTECTION VALVES XLLINE
After installation of the safety cabinet at the final point of use the fire protection valves (enclosed in the
cabinet) which have been demounted to avoid transport damages have to be fixed on the air inlet and
outlet again. The valves have also to be mounted even if there will be no technical ventilation of the safety
cabinet! For mounting of the valves (see picture) position them on the air inlet and outlet and use the screws
enclosed (4 pieces/valve) to fix them on the cabinet top (do not remove the fire protection sealings already
installed in the air inlet and outlet!
9. FIRE • DISPOSAL

19
EN
9.1. OPENING THE CABINET AFTER THE FIRE
ATTENTION:
Only authorised personnel (e.g. fire brigade) may open the cabinet!
Depending upon the duration of the fire an ignitable vapour/air mixture may have formed; therefore remove
all sources of ignition within a 10 metre radius of the cabinet before opening it.
Use only spark-free tools !
Open the cabinets with extreme caution !
9.2. DISPOSAL
The models can be disposed of once they have been dismantled and the materials sorted.
10. SAFETY CHECKS
10.1. IN GENERAL
As safety equipment the cabinets have to be checked for safety at least once per year. The next checking date
can be taken from the service sticker on the outside of the door. This annual check can be carried out with the
necessary care, and for securing your warranty claims in the case of fire, only by an authorised asecos employ-
ee (refer also to our service brochure regarding this).
In addition, we recommend that you carry out a daily and monthly functional check:
Daily functional check
• applies to the spill containment sumps (collect and remove any leakages)
Monthly functional check
• perfect function of the doors:
- hinges
- locking system
- door closer
- door open arrest system
• correct seating and condition of the fire protection seals
Case of damage
In case of damage please contact your dealer in order to have the cabinet repaired using original spare parts.
The cabinets can be cleaned with a mild household cleaner and a soft cloth.
10.2. WEARING PARTS
Various safety-related components of the safety storage cabinet are wearing parts and must be replaced at
regular intervals by asecos Service. A list of the parts aected for your safety cabinet is available on request
from [email protected].
CONTACT:
In the case of defects or complaints about our products (within and also after the warranty period), and for
requesting safety checks or taking out a service contract, please contact our service hotline on:
Tel: +44 1785 22 70-90 info@asecos.co.uk

20
EN
230
1004
438 438
150
616558
Fresh air
Exhaust air DN 75
Earthing link
S90.196.120 S90.196.120.WDAS
S90.196.120.MV.WDAS S90.129.120
S90.129.120.WDAS S90.129.120.WDAC
230
89°
708
333
150
616406
333
Fresh air Exhaust air DN 75
Earthing link
S90.196.090 S90.196.090.WDAS
260 168168
150
89°
521 616
Exhaust air DN 75
Earthing link
Fresh air
S90.196.060 S90.196.060.WDAS
S90.196.060.R S90.196.060.WDASR
S90.196.060.MH.WDAS S90.196.060.MH.WDASR
S90.129.060 S90.129.060.WDAS
S90.129.060.R S90.129.060.WDASR
S90.129.060.WDAC S90.129.060.WDACR
89°
521
260 168
284
168
749
Fresh air
Earthing link
Exhaust air DN 75
S90.196.060.075.WDAS S90.196.060.075.WDASR
230
937
483483
93°
616
150
331
Fresh air
Exhaust air DN
75
Earthing link
S90.196.120.FDAS S90.196.120.MV.FDAS
S90.196.120.FDAC S90.196.120.MV.FDAC
S90.196.120.FDAO
150
616331
230
676
93°
89°
333333
Fresh air Exhaust air DN 75
Earthing link
S90.196.090.FWAS
616311
260 168
150
93°
168
Exhaust air DN 75
Earthing link
Fresh air
S90.196.060.FDAS S90.196.060.FDASR
S90.196.060.MH.FDAS S90.196.060.MH.FDASR
S90.196.060.FDAC S90.196.060.FDACR
S90.196.060.FDAO
749311
260 168
284
93°
168
Exhaust air DN 75
Earthing link
Fresh air
S90.196.060.075.FDAS S90.196.060.075.FDASR
S90.196.060.075.FDAC S90.196.060.075.FDACR
S90.196.060.075.FDAO
1202
992 (105)
338
557
598
85
Fresh air
Earthing link
Exhaust air DN 75
K30.197.120.MC.FWAS K30.197.120.MV.FWAS
230 484
1178
150
93°
max 180°
Fresh air
Earthing link
Exhaust air DN 75
K90.196.120.MF.FWAS K90.196.120.MC.FWAS
K90.196.120.MF.FWAC K90.196.120.MC.FWAC
512532
2360
125°
1404
403
1757
Fresh air Ø75 Exhaust air DN 75
Earthing link
XL90.222.155.WDAS
362382
1645
125°
954
403
1532
Fresh air Ø75 Exhaust air
DN 75
Earthing link
XL90.222.110.WDAS
11. TECHNICAL DRAWING
This manual suits for next models
59
Table of contents
Other asecos Laboratory Equipment manuals
Popular Laboratory Equipment manuals by other brands

VERDER
VERDER Carbolite Gero PN 120 Installation, operation and maintenance instructions

Teledyne
Teledyne Foxy R1 instruction manual

DEMA
DEMA 292QD AERATING WAND installation instructions

Aven
Aven SharpVue Plus manual

Thermo Scientific
Thermo Scientific IMH 60 operating instructions

biochrom
biochrom ASYS EXPERT PLUS quick start guide