Arlington Scientific, Inc.
ASI Small Warming Pad
14”x23”Warming Pad Part #20631-002
Product Features Warming Pad Specications
• Premium SILVERGUARD® protective cover for ex-
tended life • 14”x23”Warming pad surface
• Easy to read LCD screen controller • Voltage : 115 V
• Variable control heat settings with auto shuto
safety • Current: 0.81 A
• 11 foot cord for ease of use • Wattage: 94 W
• Pad can be used under or on top of user • Internal operating temperature range: 86°F to 166°F
SILVERGUARD® Fabric Specications
• SILVERGUARD® Flame Retardant fabric ratings include: ASTM E 84-10 Adhered – Class I or A, BS 5852 – United
Kingdom – Source 0, California Tech Bulletin 117 – Section E, FMVSS 302, EN 1021 – Part 1 & 2 – 2006, NFPA
260- Cover Fabric – Class I, UFAC Fabric – Class IASTM E 84-10 Adhered – Class I or A, BS 5852 – United Kingdom
– Source 0, California Tech Bulletin 117 – Section E, EN 1021 – Part 1 & 2 – 2006, FMVSS 302, NFPA 260- Cover
Fabric – Class I, UFAC Fabric – Class I
• Backing: 100% Rayon
• Finish: Superior Abrasion ( 400,000 cycles, Wyzenbeek wire screen )
• Cold Crack: -10˚F
How SILVERGUARD® Technology Works
Silver ions engineered into the unique chemistry of SILVERGUARD® are highly
eective against bacteria because they destroy microorganisms through
multiple paths. SILVERGUARD® attacks the bacteria cell wall, disrupts protein
metabolism within the cell, and forms complexes with other biomolecules
in the cell to alter cell functions. These ions are slowly released out of their
inorganic matrix in the presence of moisture. SILVERGUARD® is released
as needed to eectively control bacterial growth, while leaving sucient
quantities of SILVERGUARD® to retain antibacterial protection.
Arlington Scientific, Inc.
CAUTION
• Do not place in direct contact with swollen, irritated or
broken skin. Users with poor circulation or neurological
sensitivity should not use this pad
• Discontinue if pain or other unusual symptoms appear
• Do not use on children or adults who are unable to
remove or monitor the warming pad
• Do not place on environmental surfaces sensitive to heat
• Do not bend or fold the warming pad
• Read and follow all manufacturer’s instructions on
warming pad label and insert
• Check patient for comfort level often. A general guide-
line is to check every 20-30 minutes and assess the
patients comfort
• Unplug when not in use
• Do not lay against bare exposed skin
• Do not use with unconscious persons or persons
sleeping for periods longer than two hours
• Do not use in or near oxygen enriched environments
• Do not immerse in water
• Do not unplug warming pad by pulling its connecting
cord
• Unplug warming pad before cleaning
DIGITAL CONTROLLER INSTRUCTIONS
• Plug warming pad into 110 V wall receptacle
• Press and hold the orange button for 2 seconds to acti-
vate the pad
• The screen will display a number indicating the tem-
perature and the current timer setting
• Press the lock/select button once to change the time
the pad will run. A clock will display in the upper left
hand corner
• Use the up/down arrows to select the run time
• Press the lock/select button one time and a thermom-
eter icon will appear
• Press the up/down arrows to set the desired tempera-
ture (Note: The degrees displayed are an internal wiring
temperature, not the “felt” temperature on the top of the
pad.)
• The status button indicates what the current tempera-
ture is and how long the pad has been running
STORAGE
• Do not fold or bend the warming pad as this will dam-
age the heating elements and void your warranty
• Gently roll up the warming pad when not in use
CLEANING SILVERGUARD® FABRIC COVER
• Always unplug warming pad before any cleaning or
service
• Step 1: For light soiling, a solution of 10% mild soap
and warm water, applied with a soft damp cloth. Rub
gently and rinse with a water dampened cloth.
• Step 2: For more dicult stains, dampen a soft white
cloth with a solution of household bleach (10% bleach
and 90% water). Rub gently and rinse with a water
dampened cloth to remove bleach concentration.
• For disinfecting: Dampen a soft white cloth with a
solution (5:1) of water and bleach. Rub gently and rinse
with a water dampened cloth.
• Any of the following solutions may be used as a clean-
ing agent:
• alcohol, water, and bleach (5:5:2)
• bleach and water (1:5)
• alcohol and water (1:1)
• Most disinfectants will not damage Polyurethanes.
All cleaners should be tested on a small, unobtrusive,
area initially to conrm no immediate eect on color
or product. Certain clothing and accessory dyes (such
as those used on denim jeans) may migrate to lighter
colors. This phenomenon is increased by humidity and
temperature and is irreversible. Please check compat-
ibility when using this product in combination with
painted or varnished surfaces.
WARRANTY
• 6 Month limited warranty from date of purchase.
• Bent or broken wires caused by improper use will void
warranty
• Tears and rips in fabric may void warranty
• This product is fully guaranteed against defects in ma-
terial or workmanship for 6 months commencing with
receipt by the original end user. If a product fails due
to a manufacturing defect, we will repair or authorize
repairs to the product without charge or replace it at
our option.
• Prior written authorization must be obtained in order
to return this product. If a product is returned with-
out prior written authorization, the customer shall be
responsible for all shipping charges and any applicable
duties and/or tax.
• When a repair is made on site, solely at the request of
the customer, the customer is responsible for all travel
costs.
• ARLINGTON SCIENTIFIC, INC. disclaims any implied
warranty of merchantability or tness for a particular
purpose and in no event shall ARLINGTON SCIENTIFIC,
INC. be liable for consequential damages.
Arlington Scientific, Inc.
1840 N. Technology Dr., Springville, UT 84663
801-489-8911 · 800-654-0146
info@arlingtonscientic.com, www.arlingtonscientic.com
6004-631 Rev. 04_2015

This manual suits for next models

1

Popular Food Warmer manuals by other brands

Casselin CCS1 manual

Casselin

Casselin CCS1 manual

Wells BMW-206ULST Specifications

Wells

Wells BMW-206ULST Specifications

ARDES AR071 Instructions for use

ARDES

ARDES AR071 Instructions for use

Gastros InductWarm Built-in solution 100 GN 1/2 Assembly instruction

Gastros

Gastros InductWarm Built-in solution 100 GN 1/2 Assembly instruction

Beurer HK 58 Instructions for use

Beurer

Beurer HK 58 Instructions for use

Avantco Equipment 177RW90 user manual

Avantco Equipment

Avantco Equipment 177RW90 user manual

Deni 15500 Instructions for proper use and care

Deni

Deni 15500 Instructions for proper use and care

Buffalo L310 instruction manual

Buffalo

Buffalo L310 instruction manual

odass OD-0704 installation manual

odass

odass OD-0704 installation manual

Olympia Milan CN607 instruction manual

Olympia

Olympia Milan CN607 instruction manual

Toastmaster 3A81D brochure

Toastmaster

Toastmaster 3A81D brochure

winholt NHPL-1833-ECOC-2D-DGT Operational, Maintenance & Service Bulletin

winholt

winholt NHPL-1833-ECOC-2D-DGT Operational, Maintenance & Service Bulletin

BEER GN-1/1 operating manual

BEER

BEER GN-1/1 operating manual

Cadco CBC-2RT Brochure & specs

Cadco

Cadco CBC-2RT Brochure & specs

TAIKO NEC-1 instruction manual

TAIKO

TAIKO NEC-1 instruction manual

Pedigo P-2110 manual

Pedigo

Pedigo P-2110 manual

CARTER-HOFFMANN MZ212S-2 Owner's/operator's manual

CARTER-HOFFMANN

CARTER-HOFFMANN MZ212S-2 Owner's/operator's manual

ROBAND AUSTRALIA KH2 operating instructions

ROBAND AUSTRALIA

ROBAND AUSTRALIA KH2 operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.