INTRODUCTION
The SURE DRAIN is designed for trouble-free draining of
unwanted accumulations of condensate and other foreign
matter from compressed air systems.
TESTINGTHESURE-DRAIN
1. Plug the SURE-DRAIN into a 115V 60HZ grounded
socket.
2.Setin"TEST" position. TheSURE-DRAINwillcycleon
(1-15 seconds as set) and off for 5 seconds in the "TEST"
position.
3.Removingandreapplyingthepowerwillcausethedrain
valvetoopenforthesetONTIME(1-15seconds).
INSTALLATIONandADJUSTMENTS
1.USECAUTION:COMPRESSEDAIRCANBEDANGER-
OUS. Besurethepressurevesselonwhichthedrainwillbe
installedisdepressurizedpriortoanyattempttoinstall the
SURE-DRAIN. DO NOT REMOVE the cover of the drain
whileitispluggedin. Ifthedraindoesnotseemtobeworking
properly, contact your distributor for return authorization.
Any attempt to repair the drain without authorization will
VOIDWARRANTY.
2.TheSURE-DRAINdrainvalvemustbeinstalledsothatthe
flowofthecondensateisinthesamedirectionasthearrow
onthevalve. Improperinstallationwillcausethevalvetoleak
and could damage the valve seat. For optimum life and
performance, the drain or valve should be mounted in a
verticalanduprightposition. Thiswouldreducethepossibil-
ityofanyforeignmatteraccumulatinginthecoretubearea.
Thedrainshouldbeinstalledasclosetosourceaspossible.
3.Fullydrainthevesselbyopeninganauxiliarygatevalve(see
Diagram 1) or switch the SURE-DRAIN to test as described
above(TestingtheSURE-DRAIN)
4.Whenallofthecondensatehas drained, set the OFF TIME
to the maximum 50 minute setting and the ON TIME to the
maximum 15 seconds.
5.Returnpriortothetimethatthedrainisexpectedtoopenand
checktoseehowlongittakesforthevalvetoexhausttheliquid.
Ifattheendofthedrainopenperiodalltheliquidhasnotbeen
expelled,adjusttheOFFTIMEdownwardandrepeatsteps3,
4, and 5.
6.SettheONTIMEequaltotheamountoftimeittakestodrain
thevessel.Wesuggestincreasingthetimeby20%tocompen-
sate for small fluctuations in air system usage or climatic
changes.
7.Thedrainshouldbecheckedperiodicallytoensureaproper
setting was achieved. In climates with large changes in
humidity, the drain should be checked and reset accordingly.
WARRANTY
The SURE-DRAIN and valves are warranted to be free from
defectsinworkmanshipandmaterialsforaperiodofoneyear
fromthedateofshipment. Theliabilityofthemanufacturerand/
ordistributorislimitedtorepairorreplacementofthedrainatits
option. Innoeventshallthemanufacturerand/ordistributorbe
liableforspecialorconsequentialdamagesorforanydelayin
performanceofthiswarranty.
INSTALLATION INSTRUCTIONS FOR THE
SURE DRAIN
1. Wire in parallel
2. Maximum of four valves per controller.
DIAGRAM 1 - INSTALLATION
DIAGRAM 2 - WIRING MULTI-VALVE DRAIN
AIRSYSTEM PRODUCTS,INC.l51BeachAve., Lancaster,NYUSAlPhone716-683-0435Fax716-683-7128

Popular Control Unit manuals by other brands

Maxim Integrated MAXIM001 MGT quick start guide

Maxim Integrated

Maxim Integrated MAXIM001 MGT quick start guide

Siemens SINUMERIK 840D Operating Turning

Siemens

Siemens SINUMERIK 840D Operating Turning

Isenberg TVH.4801 installation manual

Isenberg

Isenberg TVH.4801 installation manual

Festo VTUG-M Series quick start guide

Festo

Festo VTUG-M Series quick start guide

Opalum FLOW series Setup guide

Opalum

Opalum FLOW series Setup guide

Vision tools 09V0002B Technical manual

Vision tools

Vision tools 09V0002B Technical manual

MSA FireHawk M7 Maintenance and repair guide

MSA

MSA FireHawk M7 Maintenance and repair guide

Mottura 99.746 Installation & use instructions

Mottura

Mottura 99.746 Installation & use instructions

Emerson Sempell S Series operating instructions

Emerson

Emerson Sempell S Series operating instructions

Cooledge CASAMBI CONTROL user guide

Cooledge

Cooledge CASAMBI CONTROL user guide

Val-Matic Surgebuster Operation, maintenance and installation manual

Val-Matic

Val-Matic Surgebuster Operation, maintenance and installation manual

Renau NEA SMART Installation and operating manual

Renau

Renau NEA SMART Installation and operating manual

GGM GUF Series Operation manual

GGM

GGM GUF Series Operation manual

Emicon EMIBYTE DXi.H Use and maintenance

Emicon

Emicon EMIBYTE DXi.H Use and maintenance

Monacor ATT-210/WS manual

Monacor

Monacor ATT-210/WS manual

Siemens SENTRON 7KM PAC 4DI/2DO operating instructions

Siemens

Siemens SENTRON 7KM PAC 4DI/2DO operating instructions

Siemens 986-88301A installation instructions

Siemens

Siemens 986-88301A installation instructions

TLV A-COS-10 instruction manual

TLV

TLV A-COS-10 instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.