3
1PoE Input / Output (IN / OUT)
There sixteen RJ45 jack pairs (top and bottom pair) labeled
sequentially. For each pair, the bottom jack is for network
data input. The top jack is the data and power output.
CONNECT your data only cables to the bottom row of the
RJ45 jacks (from a network switch, video server, etc.).
CONNECT the top jacks to the corresponding PoE compatible
devices (e.g., IP cameras).
2Ethernet Input (Ethernet)
This port allows users to monitor and control the AQE
multi-port midspan injector through a computer, over a
Local Area Network (LAN) or the Internet. The management
software AQE Power Supply Control Center is web browser
based. You may connect a Personal Computer (PC) directly
to this Ethernet port, or via LAN/Internet.
3External Control (External Control)
This connector allows an external trigger voltage to shutdown
selected PoE outputs (programmed by user via the AQE
Power Supply Control Center management software).
The trigger voltage is 5 to 24V, AC or DC.
4Reset Button (Reset)
Pressing the recessed reset button with a pin for 6 seconds
will reset the IP address and password to the factory default
values.
The factory default IP address is: 192.168.1.9
The factory default user name is: admin
The factory default password is: admin
5Front Panel LEDs (1-16)
The 16 front panel LEDs (labeled 1 through 16) indicate the
port status of the corresponding PoE channels. When the
output is connected to a valid PoE Powered Device (PD)
within the specified current limit, the LED will be green,
indicating normal operation. When there is a fault condition,
such as when no PD is connected to that port, the LED will
be yellow.
The LED will be turned off if the corresponding port is
disabled by the AQE Power Supply Control Center software.
LED Status Status
Green Normal Operation
Yellow (Fault) No Powered Device connected or fault
condition present
Off Port disabled
When the AQE is first powered, these LEDs will light yellow
in sequence (1-16) six times as the unit performs a self-test.
6AC Line Input (AC Power)
This is the connector for the AC line cord.
PLUG the included computer-style line cord into this
connector.
CONNECT the other end of the cord to the power strip inside
the rack or another suitable AC power receptacle. The AQE
series accepts 120–230 VAC ONLY.
7Main AC Power Switch / Circuit Breaker (On/Off)
This is the main AC power switch for the AQE. This switch
lights when power is on and also has a built-in circuit breaker
rated at 15 Amperes (A).
If the circuit breaker trips, RESET it by cycling the switch to
off then back to on.
8External DC Voltage Input (External DC +/-)
This input may be used to either power the AQE via an
external 50 VDC supply or to provide battery backup to the
AQE. The “External DC” input is reverse polarity protected. See
below for details:
To Use Battery Backup
Connect AC power to the AQE unit as normal. In addition,
connect a 48V nominal battery set to the “External DC”
connector, using the battery cable supplied.
To Use an External 50 VDC Supply
Connect a 50V power supply to the “External DC” connector
at the rear. The ratings requirements for the DC power supply
are given below:
Input voltage range 44 – 57 VDC
Max input current (500W model) 14.0 A
Max input current (250W model) 7.0 A
Note that if both AC and DC power sources are connected to
the unit at the same time, the AC source will supply the power
to the output ports. The external DC source will not supply the
outputs unless the AC source is missing or the power switch
is turned off.
The following are basic descriptions. Refer to the appropriate section for more detailed information.
500-33600, Rev. A