Unlock
Lock
Immunity
Immunity helps to reduce the chance of
unwanted detections due to environmental
disturbances.
1 = Reduced
2 = Normal
3 = Increased
4 through 9: enhanced immunity (for highly
reflective environment)
Hold Time
0 = 0.5 sec.
9 = 20 sec
Default: 5 = 10 sec
Sensitivity
0 = Minimum Sensitivity
9 = Maximum Sensitivity
Default: 8
NOTE: Every adjustment, when using the
infrared remote control, must start with
the unlocking function, and end with the
locking function.
The amount of time door will be held open after
movement is not detected in the opening. Values
range from 0 to 9.
Default: 2
Detection Mode
Detection mode offers 3 different levels of
detection:
1 = Bi-Directional
2 = Uni-Directional
3 = Uni-Directional with motion tracking feature
Default: 1
Door Control Mode (F2)
1 = Safe Zone
2 = Infinite Hold Open
3 = Detection Off
Default: 1
To UNLOCK the sensor:
Press the UNLOCK key once.
To LOCK the sensor:
Press the LOCK key twice.
Example: Set Safe Zone to hold open 9
seconds after movement is not detected in
the opening.
Step 1 - Press unlock ; LED flashes
Step 2 - Press time ; LED flashes quickly
Step 3 - Press 9 ; LED flashes
Step 4 - Press lock ; LED flashes quickly
Step 5 - Press lock again to save setting;
LED does not flash
®
SafeZone Remote
Programming Guide
DOOR CONTROL MODE:
SafeZone - holds door open as long as movement is detected in the opening.
Infinite Hold Open - door held open constantly (with or without movement being detected).
Detection Off - standard door closer operation; open and close/no hold open.
Copyright © 2010, 2014 Yale Security Inc., an ASSA ABLOY Group company. All rights reserved.
Reproduction in whole or in part without the express written permission of Yale Security Inc. is prohibited. 80-9371-0001-000 (01-14)
SafeZone is equipped with a Motion Tracking Feature (MTF). The MTF is available when SafeZone is used in the uni-directional
mode. SafeZone is factory preset with the MTF ON. MTF is recommended for use in short vestibule areas to help reduce unwanted
door hold-open time. Refer to the Programming Guide to alter this setting. It is recommended that the MTF be enabled for all
applications. The detection capabilities perform as follows:
BI-DIRECTIONAL MODE:
• Detection of all motion towards or away from the sensor.
UNI-DIRECTIONAL MODE:
• The detector will work in a uni-directional mode at all times regardless of traffic patterns - detecting only motion moving
toward the sensor.
OR
UNI-DIRECTIONAL MODE WITH MTF: The principle is as follows:
• The detector does NOT activate its relay as long as it detects movement exclusively moving away from the detector. It
acts like the classic unidirectional detector.
• As soon as SafeZone detects movement toward the sensor, it automatically switches to bi-directional mode.
• SafeZone maintains the bi-directional function for approximately 2 seconds following the last detection of motion toward
the door.
• At the end of the 2-second time frame, if SafeZone does not detect any further motion, it switches back to the
unidirectional mode.
3000 Highway 74 East • Monroe, NC 28112
Tel: (877)- • Fax: (800)-338-0965974-2255
www. no r to ndoorcontrols. co m
ASSA ABLOY

Other Assa Abloy Remote Control manuals

Assa Abloy Yale HSA6060 User manual

Assa Abloy

Assa Abloy Yale HSA6060 User manual

Assa Abloy Yale HSA6060 User manual

Assa Abloy

Assa Abloy Yale HSA6060 User manual

Assa Abloy shine User manual

Assa Abloy

Assa Abloy shine User manual

Assa Abloy Yale SR-KF User manual

Assa Abloy

Assa Abloy Yale SR-KF User manual

Popular Remote Control manuals by other brands

Redback A 4581 operating manual

Redback

Redback A 4581 operating manual

Channel Vision A0505 instructions

Channel Vision

Channel Vision A0505 instructions

Nibe RE 10 installation instructions

Nibe

Nibe RE 10 installation instructions

Technics EUR646463 How to use

Technics

Technics EUR646463 How to use

intensity KJR-86C-E Installation & owner's manual

intensity

intensity KJR-86C-E Installation & owner's manual

Honeywell TS607 user manual

Honeywell

Honeywell TS607 user manual

FrSky HORUS X12S manual

FrSky

FrSky HORUS X12S manual

LOGICOM RM-509 installation manual

LOGICOM

LOGICOM RM-509 installation manual

Continental Refrigerator SVI-QEFGE04 user manual

Continental Refrigerator

Continental Refrigerator SVI-QEFGE04 user manual

DETRUM GAVIN-6A user manual

DETRUM

DETRUM GAVIN-6A user manual

ADS 99997 2450RF owner's manual

ADS

ADS 99997 2450RF owner's manual

WAFER AC200 manual

WAFER

WAFER AC200 manual

LOGISTY L2612 manual

LOGISTY

LOGISTY L2612 manual

Motion CM-17 manual

Motion

Motion CM-17 manual

Pioneer CD-SR80 installation manual

Pioneer

Pioneer CD-SR80 installation manual

Code Alarm ROG1 owner's manual

Code Alarm

Code Alarm ROG1 owner's manual

Dish Network 40.0 quick start guide

Dish Network

Dish Network 40.0 quick start guide

König SAS-ASRC4 QIG Series user manual

König

König SAS-ASRC4 QIG Series user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.