Tips for Measurement
(1)We recommend using the instrument under the condition of that its temperature is 10 to 40℃.
Thus, take a measurement inside car or immediately after getting out the instrument to outside car when you use at fieldwork.
( )When you can not have enough snow-melting agent for measurement, put tissue impregnated with the sample on the prism,
then take a measurement. As optional, “Round sheet” (Part No. RE-93 0) is available.
Automatic Temperature Compensation
The readings are corrected, based on the temperature of the prism, within the automatic temperature compensation range.
【Caution】
◇ Measurements may fluctuate with hot or cold samples. Wait for approximately 0 seconds to press the START button.
Measurements will stabilize once the instrument acclimates to the sample temperature.
Storage and Maintenance
Store the instrument in a dry place away from
direct sunlight. Exposure to humidity and heat
may damage the instrument.
Clean and dry the sample stage thoroughly,
following the “Cleaning” instructions.
Store the unit away from direct sunlight at a
stable temperature wit
h as little fluctuation as
possible.
Repair and Warranty
The instrument is warranted for one year from the date of purchase. This warranty is void if the instrument shows evidence of the
following. Send the included batteries as well if they are still in use.
•
Having been disassembled by unauthorized personnel
•
Damages to the prism and/or sample stage
•
Water damage or having been dropped
•
Having been misused and/or operated outside the environmental specifications
•
Leakage from batteries other than those included with the unit
Repair services are available for a fee after the warranty expires.
Contact an ATAGO authorized service center for service and support.
Please have the serial number information ready when contacting a service center.
Specifications
Measurement range Sodium chloride 0.0 to 28.0% (g/100g)
Maximum number of 100
10.0 to 100℃
data histor
Resolution 0.1% / 0.1℃
Output NFC Forum T pe 4 Tag
Accurac ±0.2% / ±1℃
ISO/IEC 14443 T pe A
Automatic temperature
10 to 100℃
Output categor : Date Time,
compensation range
Sodium chloride [g/100g], Temp [degC]
Ambient temperature 10 to 40℃
(e.g.) 2017/08/17 09:30:45, 12.3, 20.4
range
Power suppl Two (2) AAA alkaline batteries
Sample volume At least 0.3mL
Batter life Approx. 11,000 measurements
Measurement time Approx. 3 seconds
(when using alkaline batteries)
Backlight The backlight sta s on for 30 seconds
International IP65
after an button is pressed.
Protection class
Dimensions and weight 55 (W) x 31 (D) x 109 (H)mm, 100g (main unit onl )
The product is in conformity with the requirements of the EMC Directive 004/108/EC.
Patent Granted in Japan, United States, Germany, China and Taiwan.
Headquarters: The Front Tower Shiba Koen,
23rd Floor 2-6-3 Shiba-koen, Minato-ku,
Tok o 105-0011, Japan
http://www.atago.net/
TEL: 1-425-637-2107
TEL: 91-22-2854-4915 / 4071-3232
TEL: 66-21948727-9 ,66-21171549
TEL: 55 16 3913-8400
TEL: 39 02 36557267
TEL: 86-20-38108256
TEL: 7-812-777-96-96
TEL: 234-707-558-1552
TEL: 7-727-257-08-95
1803K Printed in Japan
Digital Hand-held
“
Pocket
”
Sodium chloride Snow-melting agent Refractometer
PAL-03S
Cat.No.4403
4403-E08
Instruction Manual
Parts
Contents
Main unit.........1
Instruction Manual (this book) .....1 Calibration Report .. 1
AAA batteries ...........
AAA alkaline batteries are included. Remove the tape from the battery compartment before inserting the batteries.
ATAGO instruments are rigorously inspected to ensure each unit meets the highest standards of quality assurance.
Introduction
Thank ou for purchasing the instrument. Carefull read and follow all instructions. Keep this manual for future reference.
Safety Instructions
Read and follow all safet instructions before operating the instrument. Failure to compl with the following instructions ma result in personal injur or
propert damage.
◇ Ensure safet when handling hazardous materials. Observe precautionar measures and use protective equipment, Be aware of the hazards of such
chemicals and emergenc response guidelines.
◇ ATAGO ma not be held liable for an injur or damage arising in connection with handling of hazardous materials during the use of the instrument.
◇ Do not drop the instrument or subject it to strong ph sical shock.
◇ Do not attempt to repair, modif , or disassemble the instrument.
◇ Carefull read this manual to have basic knowledge of the function of each component.
◇ ATAGO is not liable for an loss and damage caused b the measurement and use of this instrument.
◇ Some acids ma corrode the glass prism and/or metal sample stage, which ma cause erroneous measurements.
◇ Do not use metal tools, such as a spoon, as the ma scratch the prism, resulting in erroneous measurements.
◇ Do not use water above 50℃ to rinse the instrument.
◇ Onl use the specified batter t pe. Observe proper polarities, properl aligning the anodes and cathodes.
◇ Store the instrument awa from direct sunlight/heat sources and excessive amounts of dust/debris.
◇ Do not expose the instrument to a rapid change in ambient temperature.
◇ Do not subject the instrument to strong vibration.
◇ Do not subject the instrument to extreme cold temperature.
◇ Do not place the instrument under an thing heav .
◇ Loosen the batter compartment cover for air transportation.
<International Protection Classification IP65>
◇ The instrument is water-resistant, not waterproof, and should not be submerged.
<C emical Resistance of Body Case>
◇ The bod case is made of PBT resin. Do not expose it to water vapor. Some solvents ma compromise the structural integrit of the instrument.
ZERO button
zero-setting.
ZERO button
and delete data history.
The warranty period
extension method
1 year
2 years
The warranty period will
be extended from year
to 2 years when you
register customer
information.
ATAGO Logger NFC
can also be downloaded at the same
time.
Trouble scanning the code? Access
this link
http://www.atago.net/ur/
QR code
Lanyard hole
Sample stage
samples on the glass
prism located in the
center of the sample
stage.
Image is for explanation purposes onl . It ma be
different than the actual product purchased.
LCD
prism temperature,
remaining battery
charge, etc., are
displayed.
The displayed value
is an example.
measurements and
the display.
(Power button)
batteries from here.
compartment