1
M16 8 Pin Male Socket
AWP 210
DRAW WIRE SENSOR USER MANUAL
AWP 210 series draw wire sensors; consists of a rotary potentiometer which is controled by stainless
steel wire. They make measurement by pulling and rewinding stainless steel wire.
Different measuring lengths from 1000 mm to 5000 mm are avaliable. They converts linear motion to
potentiometric output.
The “A”series, works with 24VDC supply and gives of 4-20 mA analog output with the help of the
converter card.
The “V” series, works with 24VDC supply and gives of 0-10 VDC analog output with the help of the
converter card.
Optionally, different non-standard measuring lengths, cable length or socket model can be requested.
Never make or undo electrical connections to the sensor when voltage is applied, otherwise this may result in damage to
devices.
M12 5 Pin Male Socket
•The installation of the product is carried out by the customer who purchases the product, according to the wiring diagrams,
installation information, etc. in this manual.
•Maintenance and repair should be done by the technicians authorized by the manufacturer firm.
•There must be minimum distance between the sensor and control unit. Avoid additions except the suitable connector unless it
needs.
•Keep away the sensor cable from as high power energy cables, contactor, motor, switched power supplies, inductive and capacitive
noisy supplies.
•Shielding edge of the sensor cable must be ground connected.
•Not to damage the sensor, supply directions and voltage must be paid. Don’t energize before all connections completed.
•Transport and storage should be at their original packaging and an ambient temperature of -25°C / + 85°C in such a way that they
will not be exposed to dust, humudity, impact, vibration, falling or water.
•Chemicals such as alcohol, thinner etc. should not be used for cleaning the product. The product should be wiped with a damp
cloth.
•The product may be damaged and may become unusable if used outside of the specifications in the user manual.
•The product will be out of warranty if used outside of the specifications in the user manual and opened or repaired other
than authorized services.
•
WARNINGS
GENERAL INFORMATION
ELECTIRICAL CONNECTIONS
0-10V or POTENTIOMETER Connection
SIGNAL
CABLE
COLOR
M12 5 PIN
MALE SOCKET
M16 8 PIN
MALE SOCKET
Earth
Silver
Pin 1
Pin 1
+V
Red
Pin 2
Pin 2
0V
Black
Pin 3
Pin 3
0-10V / Pot
Yellow
Pin 4
Pin 4
-
-
Pin 5
Pin 5
-
-
-
Pin 6
-
-
-
Pin 7
-
-
-
Pin 8
4-20 mA Connection
SIGNAL
CABLE
COLOR
M12 5 PIN
MALE SOCKET
M16 8 PIN
MALE SOCKET
Earth
Silver
Pin 1
Pin 1
+V
Red
Pin 2
Pin 2
-
-
Pin 3
Pin 3
4-20 mA
Yellow
Pin 4
Pin 4
-
-
Pin 5
Pin 5
-
-
-
Pin 6
-
-
-
Pin 7
-
-
-
Pin 8
KK-AWP.006 03.03.21 Rev No:3
2
*Stroke (measuring)
length
Different measuring lengths from 1000
mm to 5000 mm
Required Force
10 N
Linearity
±0.25% FS
Operating Temperature
-25°C … +85°C
*Supply Voltage
‘A‘ and ‘V’ models: 24 VDC
Potentiometric output model: 42V max.
Relative Humidity
%95
*Signal Output Type
Potentiometric
0-10 VDC
4-20 mA
Materials
Housing: Aluminum/ steel /
plastic
Measuring Wire: Stainless steel
Measuring Type
Potentiometric
*Connection cable
length
3m (standard), 5m, 10m
*Resistance
5 KΩ (standard), 10 KΩ
IP Protection Class
IP53
Maximum Speed
2 m/s
Weight
≈1900 gr
Note: The technical specifications indicated by (*) vary according to the selected model. The detailed code table is shown on page 4.
MECHANICAL MOUNTING
1- The product should be mounted to the relevant area with 2
units M6 bolts(1) and nuts(5) from the mounting holes (2)
according to the mounting directions shown on page 3.
2- The sensor wire should be pulled towards the position to be
connected with the barrel bolt (4).
3-The sensor wire should be mounted on the device to be
connected by using the setting nut (3).
DIMENSIONS
TECHNICAL SPECIFICATIONS
KK-AWP.006 03.03.21 Rev No:3
3
2. Mount the sensor according to the mounting directions shown below.
3. If there is a trickle of water (like a rain), the wire outlet must not be a drip of water upstream. If needed please use guide
rollers.
4. The wire should not be pulled in angular. If needed, please use guide rollers.
1. Never release the wire after pulling. Otherwise, the coil spring will be damaged.
Guide Roller
Guide Roller
Important Note(!): Failure to comply with these recommendations, the malfunctions that may occur will not be
under the warranty.
MOUNTING AND USAGE WARNINGS
Guide Roller
Product
Description
AWP 210
Draw Wire Sensor
User Manual
1 pcs
BOX CONTENTS
KK-AWP.006 03.03.21 Rev No:3
4
(1) For other (special production) stroke lengths, please contact us.
(2) For other resistance options, please contact us.
(3) Please contact us for other cable length and socket model requests.
Sample Code 1: AWP-210-2000-5K-S13-A
Explanation: AWP 210 series, 2000 mm stroke, 5K resistance, 1 pcs M12 5 pin male socket, current output
Stroke Length (1)
Different measuring lengths
from 1000 mm to 5000 mm
AWP 210 XXX XX XXX
Electrical Connection(3)
3M : 3 m
5M : 5 m
10M : 10 m
S13 : M12 5 pin male socket
S16 : M16 8 pin male socket
PRODUCT CODE TABLE
Model
AWP 210
Output Signals
No Code : Potentiometric
V : 0-10 VDC
A : 4-20 mA
Disposal of Packagings: Packaging materials consist of recyclable materials. For providing
recycling, please dispose waste packagings to collecting points of authorized recycling facilities.
Disposal of E-Waste: This device is in conformity with WEEE Directive and consists of recyclable
materials. This product should not be disposed with general waste for preventing negative effects
on enviroment and human health. This product should be disposed to collecting points of
authorized recycling facilities. Further information can be reached from authorized unit.
Manufacturer Firm’s Title, Address Details
Manufacturer Firm: ATEK ELEKTRONİK SENSÖR TEKNOLOJİLERİ SANAYİ VE TİCARET A.Ş.
Address: Gebze OSB, 800. Sokak, No:814 Gebze/KOCAELİ/TURKEY
TEL: +90 262 673 76 00 FAX: +90 262 673 76 08
Web: www.ateksensor.com E-mail: info@ateksensor.com
Authorized Service’s Title, Address Details
Authorized Service: ATEK ELEKTRONİK SENSÖR TEKNOLOJİLERİ SANAYİ VE TİCARET A.Ş.
Address: Gebze OSB, 800. Sokak, No:814, Gebze/KOCAELİ/TURKEY
TEL: +90 262 673 76 00 FAX: +90 262 673 76 08
Web:www.ateksensor.com E-mail: info@ateksensor.com
Resistance (2)
5K: 5 KΩ (standard)
10K: 10 KΩ

Other Atek Accessories manuals

Atek AWP 810 Series User manual

Atek

Atek AWP 810 Series User manual

Atek AWP 120 Series User manual

Atek

Atek AWP 120 Series User manual

Atek RCS 2100 Series User manual

Atek

Atek RCS 2100 Series User manual

Atek INC 110 Series User manual

Atek

Atek INC 110 Series User manual

Atek INC 210 Series User manual

Atek

Atek INC 210 Series User manual

Atek AWP820 User manual

Atek

Atek AWP820 User manual

Atek AWP 110 Series User manual

Atek

Atek AWP 110 Series User manual

Atek AWP 220 User manual

Atek

Atek AWP 220 User manual

Popular Accessories manuals by other brands

Orima ORCD-351 instruction manual

Orima

Orima ORCD-351 instruction manual

Cartrend 80287 Instructions for use

Cartrend

Cartrend 80287 Instructions for use

Aspiring LIGHT 20 user manual

Aspiring

Aspiring LIGHT 20 user manual

tomado TM-2000 instruction manual

tomado

tomado TM-2000 instruction manual

Digical Reasures PowerFlask user guide

Digical Reasures

Digical Reasures PowerFlask user guide

MSI MAG CORELIQUID B120 user guide

MSI

MSI MAG CORELIQUID B120 user guide

Helioscreen Helioshade Full Cassette User, Maintenance & Warranty Manual

Helioscreen

Helioscreen Helioshade Full Cassette User, Maintenance & Warranty Manual

Gorko Systems MiWSN user manual

Gorko Systems

Gorko Systems MiWSN user manual

Sensede CB1600S operating instructions

Sensede

Sensede CB1600S operating instructions

Panasonic KX-TDA0155CE Service manual

Panasonic

Panasonic KX-TDA0155CE Service manual

Earwear EW 1103 User information

Earwear

Earwear EW 1103 User information

Perenio PECWS01 Installation and operation manual

Perenio

Perenio PECWS01 Installation and operation manual

HomeSeer HS-FLS100-G2 Quick start quide

HomeSeer

HomeSeer HS-FLS100-G2 Quick start quide

Panasonic LS-H Series instruction manual

Panasonic

Panasonic LS-H Series instruction manual

Mark 7 SwageSense Assy RL1100 installation manual

Mark 7

Mark 7 SwageSense Assy RL1100 installation manual

Honeywell Home PROSiXCT Quick installation guide

Honeywell Home

Honeywell Home PROSiXCT Quick installation guide

Chicco STYLEGO up Instructions for use

Chicco

Chicco STYLEGO up Instructions for use

Bosch rexroth RegisterControl ATEX MLC 14VRS operating instructions

Bosch

Bosch rexroth RegisterControl ATEX MLC 14VRS operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.