manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Atek
  6. •
  7. Accessories
  8. •
  9. Atek AWP 220 User manual

Atek AWP 220 User manual

KK-AWP.008 28.09.18 Rev No:0
1
* Output Signal may be potentiometric, 0-10 VDC or 4-20 mA depending on the
model (See Product code table).
AWP 220
DRAW WIRE SENSOR USER MANUAL
AWP 220 series draw wire sensors; consists of a rotary potentiometer which is controled by
stainless steel wire. They make measurement by pulling and rewinding stainless steel wire.
Different measuring lengths from 1250 mm to 7000 mm are available. They converts linear
motion to potentiometric output.
The “A”series, works with 24VDC supply and gives of 4-20 mA analog output with the help of
the converter card.
The “V” series, works with 24VDC supply and gives of 0-10 VDC analog output with the help of
the converter card.
Optionally, different non-standard measuring lengths, cable length or socket model can be
requested.
Never make or undo electrical connections to the sensor when voltage is applied, otherwise this may result in damage to
devices.
SIGNAL
CABLE COLOR
M12 5 PIN MALE SOCKET
Earth
Silver (mesh)
Pin 1
+V
Red
Pin 2
0V
Black
Pin 3
Output Signal*
Yellow
Pin 4
-
-
Pin 5
M12 5 Pin Male Socket
The installation of the product is carried out by the customer who purchases the product, according to the wiring diagrams,
installation information, etc. in this manual.
Maintenance and repair should be done by the technicians authorized by the manufacturer firm.
There must be minimum distance between the sensor and control unit. Avoid additions except the suitable connector unless it
needs.
Keep away the sensor cable from as high power energy cables, contactor, motor, switched power supplies, inductive and capacitive
noisy supplies.
Shielding edge of the sensor cable must be ground connected.
Not to damage the sensor, supply directions and voltage must be paid attention. Don’t energize before all connections completed.

Transport and storage should be at their original packaging and an ambient temperature of -25°C / + 85°C in such a way that they
will not be exposed to dust, humudity, impact, vibration, falling or water.
Chemicals such as alcohol, thinner etc. should not be used for cleaning the product. The product should be wiped with a damp
cloth.
The product may be damaged and may become unusable if used outside of the specifications in the user manual.
The product will be out of warranty if used outside of the specifications in the user manual and opened or repaired other
than authorized services.

WARNINGS
GENERAL INFORMATION
ELECTRICAL CONNECTIONS
KK-AWP.008 28.09.18 Rev No:0
2
*Stroke (measuring)
length
Different measuring lengths from 1250
mm to 7000 mm
Required Force
10 N
Linearity
±0.25% FS
Operating
Temperature
-25°C … +85°C
*Supply Voltage
‘A‘ and ‘V’ models: 24 VDC
Potentiometric output model: 42V max.
Relative Humidity
%95
*Signal Output Type
Potentiometric
0-10 VDC
4-20 mA
Materials
Housing: Aluminum/steel /ABS
plastic
Measuring Wire: Stainless steel
(0.5mm or 1mm)
Measuring Type
Potentiometric
*Connection cable
length
3m (standard), 5m, 10m
*Resistance
5 KΩ (standard), 10 KΩ
IP Protection Class
IP65
Maximum Speed
2 m/s
Weight
≈1900 gr
Note: The technical specifications indicated by (*) vary according to the selected model. The detailed code table is shown on page 4.
MECHANICAL MOUNTING
1- The product should be mounted to the relevant area with 2 units
M4 bolts(1) and nuts(2) from the mounting rails (3) according to the
mounting directions shown on page 3.
2- The sensor wire should be pulled towards the position to be
connected with the barrel bolt (5).
3-The sensor wire should be mounted on the device to be connected
by using the setting nut (4).
DIMENSIONS
TECHNICAL SPECIFICATIONS
KK-AWP.008 28.09.18 Rev No:0
3
2. Mount the sensor according to the mounting directions shown below.
3. If there is a trickle of water (like a rain), the wire outlet must not be a drip of water upstream. If needed please use guide
rollers.
4. The wire should not be pulled in angular. If needed, please use guide rollers.
1. Never release the wire after pulling. Otherwise, the coil spring will be damaged.
Guide Roller
Guide Roller
Important Note(!): Failure to comply with these recommendations, the malfunctions that may occur will not be
under the warranty.
MOUNTING AND USAGE WARNINGS
Guide Roller
Product
Description
AWP 220
Draw Wire Sensor
Mounting Equipment
4 pcs M4 bolts and nuts
User Manual
1 pcs
BOX CONTENTS
KK-AWP.008 28.09.18 Rev No:0
4
Stroke Length (1)
Different measuring lengths
from 1250 mm to 7000 mm
(1) For other (special production) stroke lengths, please contact us.
(2) For other resistance options, please contact us.
(3) Please contact us for other cable length and socket model requests.
Sample Code 1: AWP-220-2000-5K-S13-A
Explanation: AWP 220 series, 2000 mm stroke, 5K resistance, 1 pcs M12 5 pin male socket, current output
AWP 220 XXX XX X XX
PRODUCT CODE TABLE
Model
AWP 220
Output Signals
No Code : Potentiometric
V : 0-10 VDC
A : 4-20 mA
Electrical Connection(3)
3M : 3 m
5M : 5 m
10M : 10 m
S13 : M12 5 pin male socket
Disposal of Packagings: Packaging materials consist of recyclable materials. For providing
recycling, please dispose waste packagings to collecting points of authorized recycling facilities.
Disposal of E-Waste: This device is in conformity with WEEE Directive and consists of recyclable
materials. This product should not be disposed with general waste for preventing negative effects
on enviroment and human health. This product should be disposed to collecting points of
authorized recycling facilities. Further information can be reached from authorized unit.
Manufacturer Firm’s Title, Address Details
Manufacturer Firm: ATEK SENSÖR SANAYİ VE TİCARET A.Ş.
Address: Tuzla KOSB Organize Sanayi Bolgesi Melek Aras Bulvari, No:67 34956 Tuzla-Istanbul / TURKEY
TEL: +90 0216 399 44 04 FAX: +90 0216 399 44 02
Web: www.ateksensor.com E-mail: info@ateksensor.com
Authorized Service’s Title, Address Details
Authorized Service: ATEK SENSÖR SANAYİ VE TİCARET A.Ş.
Address: Tuzla KOSB Organize Sanayi Bolgesi Melek Aras Bulvari, No:67 34956 Tuzla-Istanbul / TURKEY
TEL: +90 0216 399 44 04 FAX: +90 0216 399 44 02
E-mail: info@ateksensor.com
Resistance (2)
5K: 5 KΩ (standard)
10K: 10 KΩ

Other Atek Accessories manuals

Atek AWP 120 Series User manual

Atek

Atek AWP 120 Series User manual

Atek AWP 210 User manual

Atek

Atek AWP 210 User manual

Atek INC 110 Series User manual

Atek

Atek INC 110 Series User manual

Atek RCS 2100 Series User manual

Atek

Atek RCS 2100 Series User manual

Atek AWP 110 Series User manual

Atek

Atek AWP 110 Series User manual

Atek AWP820 User manual

Atek

Atek AWP820 User manual

Atek INC 210 Series User manual

Atek

Atek INC 210 Series User manual

Atek AWP 810 Series User manual

Atek

Atek AWP 810 Series User manual

Popular Accessories manuals by other brands

Fishman Powerbridge TSV installation guide

Fishman

Fishman Powerbridge TSV installation guide

NuTone LA226WH Installation & operating instructions

NuTone

NuTone LA226WH Installation & operating instructions

ScentAir WHISPER PRO user manual

ScentAir

ScentAir WHISPER PRO user manual

CyberPower CP2500NLS Product guide

CyberPower

CyberPower CP2500NLS Product guide

Opticon EBS-30 Specification manual

Opticon

Opticon EBS-30 Specification manual

DYNATEK DSMS-4 installation instructions

DYNATEK

DYNATEK DSMS-4 installation instructions

Atlona OmniStream AT-OMNI-232 installation guide

Atlona

Atlona OmniStream AT-OMNI-232 installation guide

nux Pocket Port user manual

nux

nux Pocket Port user manual

Continuum Cobra S owner's manual

Continuum

Continuum Cobra S owner's manual

AIA NEX27 Series Installation and maintenance  instruction

AIA

AIA NEX27 Series Installation and maintenance instruction

CBA RA-4961-PRQ user manual

CBA

CBA RA-4961-PRQ user manual

Tri-Tronics SMARTEYE SmartDot Installation instructions manual

Tri-Tronics

Tri-Tronics SMARTEYE SmartDot Installation instructions manual

KROHNE 1000 Series Supplementary instructions

KROHNE

KROHNE 1000 Series Supplementary instructions

Lightolier FBP100FE specification

Lightolier

Lightolier FBP100FE specification

Memmert HPP operating instructions

Memmert

Memmert HPP operating instructions

MAMAC SYSTEMS TE-701 technical information

MAMAC SYSTEMS

MAMAC SYSTEMS TE-701 technical information

Tascam us-2x2 Reference manual

Tascam

Tascam us-2x2 Reference manual

Sea-Bird Electronics SBE 63 user manual

Sea-Bird Electronics

Sea-Bird Electronics SBE 63 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.