Atek AWP 810 Series User manual

KK-AWP.012 03.03.21 Rev No:3
1
AWP 810
AWP 810 series draw wire sensors; consists of a rotary potentiometer which is controled by
stainless steel wire. They make measurement by pulling and rewinding stainless steel wire.
Different measuring lengths from 2000 mm to 5100 mm are available. They converts linear
motion to potentiometric output.
The “A” series, works with 24VDC supply and gives of 4-20 mA analog output with the help of the
converter card.
The “V” series, works with 24VDC supply and gives of 0-10 VDC analog output with the help of the
converter card.
Optionally, redundant output, different non-standard measuring lengths, cable length or socket
model can be requested.
DRAW WIRE SENSOR USER MANUAL
Never make or undo electrical connections to the sensor when voltage is applied, otherwise this may result in damage to
devices. AWP 810 can be optionally requested as single output or redundant.
•The installation of the product is carried out by the customer who purchases the product, according to the wiring diagrams,
installation information, etc. in this manual.
•Maintenance and repair should be done by the technicians authorized by the manufacturer firm.
•There must be minimum distance between the sensor and control unit. Avoid additions except the suitable connector unless it
needs.
•Keep away the sensor cable from as high power energy cables, contactor, motor, switched power supplies, inductive and capacitive
noisy supplies.
•Shielding edge of the sensor cable must be ground connected.
•Not to damage the sensor supply directions and voltage must be paid attention. Don’t energize before all connections completed.
•Transport and storage should be at their original packaging and an ambient temperature of -25°C / + 85°C in such a way that they
will not be exposed to dust, humudity, impact, vibration, falling or water.
•Chemicals such as alcohol, thinner etc. should not be used for cleaning the product. The product should be wiped with a damp
cloth.
•The product may be damaged and may become unusable if used outside of the specifications in the user manual.
•The product will be out of warranty if used outside of the specifications in the user manual and opened or repaired other
than authorized services.
WARNINGS
GENERAL INFORMATION
ELECTIRICAL CONNECTIONS
* 1 pcs M12 5 pin male connector is used as standard for single output models
* Redundant models have two outputs. 1 pcs M12 5 pin male and 1 pcs M12 5 pin female sockets are used as standard.
* Different socket models can be requested optionally.
M12 5 Pin Male Socket
M12 5 Pin Female Socket
0-10V or POTENTIOMETER Connection
Signal
Cable Color
M12 5 pin male socket
Earth
Silver
Pin 1
+V
Red
Pin 2
0V
Black
Pin 3
0-10V / Pot
Yellow
Pin 4
-
-
Pin 5
4-20 mA Connection
Signal
Cable Color
M12 5 pin male socket
Earth
Silver
Pin 1
+V
Red
Pin 2
-
-
Pin 3
4-20 mA
Yellow
Pin 4
-
-
Pin 5

KK-AWP.012 03.03.21 Rev No:3
2
*Stroke (measuring)
length
Different measuring lengths from 2000
mm to 5100 mm
Required Force
12 N
Linearity
±0.25% FS
Operating
Temperature
-25°C … +85°C
*Supply Voltage
‘A‘ and ‘V’ models: 24 VDC
Potentiometric output model: 42V max.
Relative Humidity
%95
*Signal Output Type
Potentiometric
0-10 VDC
4-20 mA
(Optionally Redundant Output)
Materials
Housing: Aluminum/steel /plastic
Measuring Wire: Stainless steel
Measuring Type
Potentiometric
*Connection cable
length
3m (standard), 5m, 10m
*Resistance
5 KΩ (standard), 10 KΩ
IP Protection Class
IP65
Maximum Speed
2 m/s
Weight
≈2200 gr
Note: The technical specifications indicated by (*) vary according to the selected model. The detailed code table is shown on page 4.
MECHANICAL MOUNTING
1-The product should be mounted to the relevant area with 2
units M6 stud bolts(1) and nuts(5) from the mounting holes
(2) according to the mounting directions shown on page 3.
2-The sensor wire should be pulled towards the position to
be connected with the barrel bolt (4).
3-The sensor wire should be mounted on the device to be
connected by using the setting nut (3).
DIMENSIONS
TECHNICAL SPECIFICATIONS

KK-AWP.012 03.03.21 Rev No:3
3
2. Mount the sensor according to the mounting directions shown below.
3. If there is a trickle of water (like a rain), the wire outlet must not be a drip of water upstream. If needed please use guide
rollers.
4. The wire should not be pulled in angular. If needed, please use guide rollers.
1. Never release the wire after pulling. Otherwise, the coil spring will be damaged.
Guide Roller
Important Note(!): Failure to comply with these recommendations, the malfunctions that may occur will not be
under the warranty.
MOUNTING AND USAGE WARNINGS
Guide Roller
Guide Roller

KK-AWP.012 03.03.21 Rev No:3
4
(1) For other (special production) stroke lengths, please contact us.
(2) For other resistance options, please contact us.
(3) As standard;
For single output models.1 pcs M12 5 pin male socket (S13M) is used.
For redundant models, 1 pcs M12 5 pin female + 1 pcs M12 5 pin male socket (S13FM) is used.
Please contact us for other socket model requests.
Sample Code 1: AWP-810-3000-5K-S13F-A-DUAL
Explanation: AWP 810 series, 3000 mm stroke, 5K resistance, 2 pcs M12 5 pin female socket, current output, redundant output
Sample Code 2: AWP-810-3000-5K-S13FM-DUAL
Explanation: AWP 810 series, 3000 mm stroke, 5K resistance, 1 pcs M12 5 pin female + 1 pcs M12 5 pin male socket, potentiometric
output, redundant output
PRODUCT CODE TABLE
Stroke Length(1)
Different measuring lengths from
2000 mm to 5100 mm
Electrical Connection(3)
3M : 3 m
5M : 5 m
10M : 10 m
S13F : M12 5 pin female socket
S13M : M12 5 pin male socket
S13FM: M12 5 pin female + M12 5 pin male
socket (available on redundant models)
Output Signals
No Code : Potentiometric
V : 0-10 VDC
A : 4-20 mA
Disposal of Packagings: Packaging materials consist of recyclable materials. For providing recycling, please
dispose waste packagings to collecting points of authorized recycling facilities.
Disposal of E-Waste: This device is in conformity with WEEE Directive and consists of recyclable materials.
This product should not be disposed with general waste for preventing negative effects on enviroment and
human health. This product should be disposed to collecting points of authorized recycling facilities. Further
information can be reached from authorized unit.
AWP 810 XXX XX XXX XX
Model
AWP 810
Resistance(2)
5K: 5 KΩ (standard)
10K: 10 KΩ
Output Type
No Code : Single Output
Dual : Redundant
Output
Product
Description
AWP 810
Draw Wire Sensor
User Manual
1 pcs
BOX CONTENTS
Manufacturer Firm’s Title, Address Details
Manufacturer Firm: ATEK ELEKTRONİK SENSÖR TEKNOLOJİLERİ SANAYİ VE TİCARET A.Ş.
Address: Gebze OSB Mahallesi, 800. Sokak, No:814/1 Gebze, KOCAELİ/TURKEY
TEL: +90 262 673 76 00 FAX: +90 262 673 76 08
Web: www.ateksensor.com E-mail: info@ateksensor.com
Authorized Service’s Title, Address Details
Authorized Service: ATEK ELEKTRONİK SENSÖR TEKNOLOJİLERİ SANAYİ VE TİCARET A.Ş.
Address: Gebze OSB Mahallesi, 800. Sokak, No:814/1 Gebze, KOCAELİ/TURKEY
TEL: +90 262 673 76 00 FAX: +90 262 673 76 08
Web: www.ateksensor.com E-mail: info@ateksensor.com
Other Atek Accessories manuals
Popular Accessories manuals by other brands

SICK
SICK GSE2 Flat Side operating instructions

Sanitas
Sanitas SIL 29 Instructions for use

Bugaboo
Bugaboo wheeled board manual

S+S Regeltechnik
S+S Regeltechnik HYGRASGARD DHKF Series Operating Instructions, Mounting & Installation

Nabco
Nabco Gyro Tech Acuvision instruction manual

Conrad
Conrad 2380482 operating instructions