Atek AWP820 User manual

KK-AWP.014 03.03.21 Rev No:3
1
* 1 pcs M12 5 pin male connector is used as standard for single output models
* Redundant models have two outputs. 1 pcs M12 5 pin male and 1 pcs M12 5 pin female sockets are used as standard.
* Different socket models can be requested optionally.
AWP 820
AWP 820 series draw wire sensors; consists of a rotary potentiometer which is controled by
stainless steel wire. They make measurement by pulling and rewinding stainless steel wire.
Different measuring lengths from 6000 mm to 8000 mm are available. They converts linear
motion to potentiometric output.
The “A” series, works with 24VDC supply and gives of 4-20 mA analog output with the help of the
converter card.
The “V” series, works with 24VDC supply and gives of 0-10 VDC analog output with the help of the
converter card.
Optionally, redundant output, different non-standard measuring lengths, cable length or socket
model can be requested.
DRAW WIRE SENSOR USER MANUAL
Never make or undo electrical connections to the sensor when voltage is applied, otherwise this may result in damage to
devices. AWP 820 can be optionally requested as single output or redundant.
•The installation of the product is carried out by the customer who purchases the product, according to the wiring diagrams,
installation information, etc. in this manual.
•Maintenance and repair should be done by the technicians authorized by the manufacturer firm.
•There must be minimum distance between the sensor and control unit. Avoid additions except the suitable connector unless it
needs.
•Keep away the sensor cable from as high power energy cables, contactor, motor, switched power supplies, inductive and capacitive
noisy supplies.
•Shielding edge of the sensor cable must be ground connected.
•Not to damage the sensor supply directions and voltage must be paid attention. Don’t energize before all connections completed.
•Transport and storage should be at their original packaging and an ambient temperature of -25°C / + 85°C in such a way that they
will not be exposed to dust, humudity, impact, vibration, falling or water.
•Chemicals such as alcohol, thinner etc. should not be used for cleaning the product. The product should be wiped with a damp
cloth.
•The product may be damaged and may become unusable if used outside of the specifications in the user manual.
•The product will be out of warranty if used outside of the specifications in the user manual and opened or repaired other
than authorized services.
WARNINGS
GENERAL INFORMATION
ELECTIRICAL CONNECTIONS
M12 5 Pin Male Socket
M12 5 Pin Female Socket
0-10V or POTENTIOMETER Connection
Signal
Cable Color
M12 5 pin male socket
Earth
Silver
Pin 1
+V
Red
Pin 2
0V
Black
Pin 3
0-10V / Pot
Yellow
Pin 4
-
-
Pin 5
4-20 mA Connection
Signal
Cable Color
M12 5 pin male socket
Earth
Silver
Pin 1
+V
Red
Pin 2
-
-
Pin 3
4-20 mA
Yellow
Pin 4
-
-
Pin 5
KK-AWP.014 03.03.21 Rev No:3
2
*Stroke (measuring)
length
Different measuring lengths from 6000
mm to 8000 mm
Required Force
12 N
Linearity
±0.25% FS
Operating
Temperature
-25°C … +85°C
*Supply Voltage
‘A‘ and ‘V’ models: 24 VDC
Potentiometric output model: 42V max.
Relative Humidity
%95
*Signal Output Type
Potentiometric
0-10 VDC
4-20 mA
(Optionally Redundant Output)
Materials
Housing: Aluminum/steel /ABS
plastic
Measuring Wire: Stainless steel
(0,8mm)
Measuring Type
Potentiometric
*Connection cable
length
3m (standard), 5m, 10m
*Resistance
5 KΩ (standard), 10 KΩ
IP Protection Class
IP65
Maximum Speed
2 m/s
Weight
≈3200 gr
Note: The technical specifications indicated by (*) vary according to the selected model. The detailed code table is shown on page 4.
MECHANICAL MOUNTING
1-The product should be mounted to the relevant area with 2
units M6 stud bolts(1) and nuts(5) from the mounting holes
(2) according to the mounting directions shown on page 3.
2-The sensor wire should be pulled towards the position to
be connected with the barrel bolt (4).
3-The sensor wire should be mounted on the device to be
connected by using the setting nut (3).
DIMENSIONS
TECHNICAL SPECIFICATIONS
KK-AWP.014 03.03.21 Rev No:3
3
2. Mount the sensor according to the mounting directions shown below.
3. If there is a trickle of water (like a rain), the wire outlet must not be a drip of water upstream. If needed please use guide
rollers.
4. The wire should not be pulled in angular. If needed, please use guide rollers.
1. Never release the wire after pulling. Otherwise, the coil spring will be damaged.
Guide Roller
Important Note(!): Failure to comply with these recommendations, the malfunctions that may occur will not be
under the warranty.
MOUNTING AND USAGE WARNINGS
Guide Roller
Guide Roller
KK-AWP.014 03.03.21 Rev No:3
4
(1) For other (special production) stroke lengths, please contact us.
(2) For other resistance options, please contact us.
(3) As standard;
For single output models.1 pcs M12 5 pin male socket (S13M) is used.
For redundant models, 1 pcs M12 5 pin female + 1 pcs M12 5 pin male socket (S13FM) is used.
Please contact us for other socket model requests.
Sample Code 1: AWP-820-8000-5K-S13F-A-DUAL
Explanation: AWP 820 series, 8000 mm stroke, 5K resistance, 2 pcs M12 5 pin female socket, current output, redundant output
Sample Code 2: AWP-820-8000-5K-S13FM-DUAL
Explanation: AWP 820 series, 8000 mm stroke, 5K resistance, 1 pcs M12 5 pin female + 1 pcs M12 5 pin male socket, potentiometric
output, redundant output
PRODUCT CODE TABLE
Stroke Length(1)
Different measuring lengths from
6000 mm to 8000 mm
Electrical Connection(3)
3M : 3 m
5M : 5 m
10M : 10 m
S13F : M12 5 pin female socket
S13M : M12 5 pin male socket
S13FM: M12 5 pin female + M12 5 pin male
socket (available on redundant models)
Output Signals
No Code : Potentiometric
V : 0-10 VDC
A : 4-20 mA
AWP 820 XXX XX XXX XX
Model
AWP 820
Product
Description
AWP 820
Draw Wire Sensor
User Manual
1 pcs
BOX CONTENTS
Disposal of Packagings: Packaging materials consist of recyclable materials. For providing recycling, please
dispose waste packagings to collecting points of authorized recycling facilities.
Disposal of E-Waste: This device is in conformity with WEEE Directive and consists of recyclable materials.
This product should not be disposed with general waste for preventing negative effects on enviroment and
human health. This product should be disposed to collecting points of authorized recycling facilities. Further
information can be reached from authorized unit.
Manufacturer Firm’s Title, Address Details
Manufacturer Firm: ATEK ELEKTRONİK SENSÖR TEKNOLOJİLERİ SANAYİ VE TİCARET A.Ş.
Address: Gebze OSB, 800. Sokak, No:814 Gebze/KOCAELİ/TURKEY
TEL: +90 262 673 76 00 FAX: +90 262 673 76 08
Web: www.ateksensor.com E-mail: info@ateksensor.com
Authorized Service’s Title, Address Details
Authorized Service: ATEK ELEKTRONİK SENSÖR TEKNOLOJİLERİ SANAYİ VE TİCARET A.Ş.
Address: Gebze OSB, 800. Sokak, No:814, Gebze/KOCAELİ/TURKEY
TEL: +90 262 673 76 00 FAX: +90 262 673 76 08
Web: www.ateksensor.com E-mail: info@ateksensor.com
Resistance(2)
5K: 5 KΩ (standard)
10K: 10 KΩ
Output Type
No Code : Single Output
Dual : Redundant
Output

Other Atek Accessories manuals

Atek AWP 110 Series User manual

Atek

Atek AWP 110 Series User manual

Atek INC 210 Series User manual

Atek

Atek INC 210 Series User manual

Atek INC 110 Series User manual

Atek

Atek INC 110 Series User manual

Atek AWP 120 Series User manual

Atek

Atek AWP 120 Series User manual

Atek AWP 220 User manual

Atek

Atek AWP 220 User manual

Atek AWP 210 User manual

Atek

Atek AWP 210 User manual

Atek RCS 2100 Series User manual

Atek

Atek RCS 2100 Series User manual

Atek AWP 810 Series User manual

Atek

Atek AWP 810 Series User manual

Popular Accessories manuals by other brands

Silvercrest Wifi Socket SWS-A1 Operation and safety notes

Silvercrest

Silvercrest Wifi Socket SWS-A1 Operation and safety notes

MD SPORTS WSP100_067G Assembly instructions

MD SPORTS

MD SPORTS WSP100_067G Assembly instructions

Heath Zenith InTune MP3 Door Chime quick start guide

Heath Zenith

Heath Zenith InTune MP3 Door Chime quick start guide

Heath Zenith 6180 Series user manual

Heath Zenith

Heath Zenith 6180 Series user manual

Planet HZS-300E user manual

Planet

Planet HZS-300E user manual

Pro-Aqua JL037255NPF manual

Pro-Aqua

Pro-Aqua JL037255NPF manual

Silvercrest SPB 5200 A1 Operating instructions and safety instructions

Silvercrest

Silvercrest SPB 5200 A1 Operating instructions and safety instructions

IR-Tec TRANS LMD-509 Series installation instructions

IR-Tec

IR-Tec TRANS LMD-509 Series installation instructions

iChime The Play Anything Doorbell instruction manual

iChime

iChime The Play Anything Doorbell instruction manual

Tripp Lite B114-004-R user manual

Tripp Lite

Tripp Lite B114-004-R user manual

I.SOUND 4589 instruction manual

I.SOUND

I.SOUND 4589 instruction manual

HYDACELECTRONIC HLS 528 user manual

HYDACELECTRONIC

HYDACELECTRONIC HLS 528 user manual

M Climate LoRaWAN MC-LW-Flood user manual

M Climate

M Climate LoRaWAN MC-LW-Flood user manual

Heath Zenith Notif owner's manual

Heath Zenith

Heath Zenith Notif owner's manual

Bin Master NCR-80 operating instructions

Bin Master

Bin Master NCR-80 operating instructions

Paradox NV780MR installation manual

Paradox

Paradox NV780MR installation manual

Life Fitness TCWHL parts list

Life Fitness

Life Fitness TCWHL parts list

Scan Cool SD 226 BE user manual

Scan Cool

Scan Cool SD 226 BE user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.