Atlona Velocity System AT-VSP-800-BL User manual

Installation Guide
AT-VSP-800-BL and AT-VSP-800-WH
1
Velocity System 8” Scheduling Touch Panel
AT-VSP-800-BL and AT-VSP-800-WH
The Atlona AT-VSP-800 is a Velocity System 8” scheduling touch panel. It features contemporary,
rened styling with 1280×800 native resolution, and a capacitive glass surface that supports
multi-touch and gesture interactions. Bright LED lighting on the edge of the bezel is ideal for
providing a visual representation of room status in scheduling applications. This touch panel
conveniently installs into a wall or furniture via a one-gang US, UK, or EU opening. The VSP-800
features Power over Ethernet (PoE), enabling a single network connection for data and power.
Setting up the touch panel is eortless as room scheduling and AV control GUIs are automatically
uploaded from the Velocity System hardware or software server gateway during system
conguration.
1 x AT-VSP-800
1 x Metal mounting plate
4 x Mounting screws
1 x Installation Guide
Package Contents
Operating Notes
• The Velocity 8” Scheduling Touch Panel (AT-VSP-800) must be on the same network as the
Velocity Gateway (AT-VGW-HW-3/10/20) or it will be unable to sync for scheduling.
• The AT-VTP-800 is PoE capable, to power the unit, simply plug it into a 802.3af compatible
network switch. If the network switch is not PoE capable, a PoE injector (purchased separately)
can be used.
IMPORTANT: Velocity Gateway (AT-VGW-HW-3/10/20) must be set up before the AT-
VSP-800 is fully functional.

Installation Guide
AT-VSP-800-BL and AT-VSP-800-WH
2
Mounting Instructions
The AT-VSP-800 can be mounted to a 1 gang back plate.
1 Select the type of 1 gang back box to use and install into a wall.
2 Thread the Ethernet cable through the 1 gang box.
3 Install the included mounting plate into the 1 gang box.
a If using a UK back box, place the screws in the two inside mounting holes.
b If using a US back box, place the screws through the outside screw holes.
4 Loosen or remove the two screws located at the top and bottom of the unit.
5 Place the unit onto the metal back plate, the dual prongs inserting into the small opening on
the back of the unit.
6 Tighten/attach the screws at the top and bottom of the touch pad.
NOTE: Install using the region’s safety guidelines for electrical boxes.
NOTE: To avoid damage to the unit, do not overtighten the screws.
24V DC / 0.5A
LAN / PoE
802.3af compliant
Designed in the USA
Manufactured in Taiwan

Installation Guide
AT-VSP-800-BL and AT-VSP-800-WH
3
24V DC / 0.5A
LAN / PoE
802.3af compliant
Designed in the USA
Manufactured in Taiwan
Installation and Set Up
1 Connect the Ethernet cable into the back of the unit.
a If the Ethernet cable is connected to a non PoE switch, use a PoE injector using 802.3at
(purchased separately).
2 Secure the unit in either the wall or optional stand, as explained in the mounting instructions.
3 The Velocity logo will display during the booting process and will go directly into setup.
Press CONTINUE to start the setup process.
NOTE: Installation of the Velocity Touch Panel can only be done after the AT-VGW-
HW-3/10/20 has been set up. View the AT-VGW-HW-3/10/20 Installation Guide and
Velocity Manual for instructions.
Initial Setup
CONTINUE
You will be guided through the setup process
in the next few screens.
4 When the unit displays the IP information, press CONTINUE.
a If the touch panel does not display an IP, select the Set Static IP slider.
b Assign the unit a static IP. Ensure there are no other devices on the network with the
same IP to avoid connection issues.

Installation Guide
AT-VSP-800-BL and AT-VSP-800-WH
4
5. The unit will load a new screen. Change the Device Alias (if needed) to help dierentiate
when there are multiple touch panels at a site.
6. Press the SCAN FOR GATEWAYS button.
7 The touch panel will scan for new gateways. Once the correct gateway is found, press USE.
Velocity Device Setup
Set Static IP
IP Address
Subnet Mask
Default
Gateway
DNS Server 75.75.75.75
10.0.0.1
255.255.255.0
10.0.0.123
CONTINUE
Velocity Device Setup
Device Alias
URL 0.0.0.0
Velocity Scheduling Panel 800
SCAN FOR GATEWAYS
SAVE & CONTINUEBACK
Alt. URL 0.0.0.0
Scanning for Gateways
CANCEL
Scanning for Gateways
CANCEL
USE
10.0.0.234
CANCEL
Synchronizing
Waiting for Approval
8 On a network computer, use a browser to log into Velocity.
9 A green message will appear at the top right corner of the screen. Select Buildings.

Installation Guide
AT-VSP-800-BL and AT-VSP-800-WH
5
10 On the buildings screen, press the Synchronize button on the building the touch panel is
located.
11 When the rooms page opens, press the Sync Scheduler button on the touch panel’s room.
12 Press the SAVE & CONTINUE button on the touch panel.
Velocity Device Setup
Device Alias
URL 10.0.0.234
SCAN FOR GATEWAYS
SAVE & CONTINUEBACK
URL 10.0.0.234
Velocity Scheduling Panel 800
Advanced Settings
Verify your PIN
554361
ABC DEF
GHI JKL MNO
PQRS TUV WXYZ
1 2 3
4 5 6
7 8
0
9
CANCEL VERIFY
URL
GATEWAY SETTINGS
TOUCH SCREEN SETTINGS
System Volume
Screen Brightness
0.0.0.0
REFRESH PAGE
CLEAN SCREEN CLOSE
ABOUT VELOCITY ADVANCED SETUP
Once th touch pad has been set up, the settings can be changed or reset only through the
advanced settings.
1 To access the settings, swipe from the left side of the touch pad to the right.
2 Select Advanced Setup.
3 Type in the PIN. Default PIN is 554361.

Installation Guide
AT-VSP-800-BL and AT-VSP-800-WH
6
ABC DEF
GHI JKL MNO
PQRS TUV WXYZ
1 2 3
4 5 6
7 8
0
9
CANCEL VERIFY
Set Configuration PIN
(Note: Once a pin is set, it will be required to edit settings going
forward)
(Enter a blank pin to remove)
ADVANCED SETTINGS
Set Static IP
IP Address
Subnet Mask
Default Gateway
DNS Server 75.75.75.75
10.0.0.1
255.255.255.0
10.0.0.123
URL
Gateway Settings
Device Settings
Touch Screen LAN Configuration
0.0.0.0
Alternate URL 0.0.0.0
Alias Velocity Scheduling Panel 800
SAVE
FACTORY RESET
CLEAR CACHE
SCAN NETWORK
CANCEL
SET PIN
ADVANCED SETTINGS
Set Static IP
IP Address
Subnet Mask
Default Gateway
DNS Server 75.75.75.75
10.0.0.1
255.255.255.0
10.0.0.123
URL
Gateway Settings
Device Settings
Touch Screen LAN Configuration
0.0.0.0
Alternate URL 0.0.0.0
Alias Velocity Scheduling Panel 800
SAVE
FACTORYRESET
CLEAR CACHE
SCAN NETWORK
CANCEL
SET PIN
Cache has been successfully cleared. Press
OK to restart.
OK
ADVANCED SETTINGS
Set Static IP
IP Address
Subnet Mask
Default Gateway
DNS Server 75.75.75.75
10.0.0.1
255.255.255.0
10.0.0.123
URL
Gateway Settings
Device Settings
Touch Screen LAN Configuration
0.0.0.0
Alternate URL 0.0.0.0
Alias Velocity Scheduling Panel 800
SAVE
FACTORYRESET
CLEAR CACHE
SCAN NETWORK
CANCEL
SET PIN
Changing advanced settings requires
application restart.
OK
Within the advanced settings, all the touch pad settings can be changed or reset.
Gateway Settings -
a If the gateway IP is known, it can be typed into the URL eld.
b If the gateway IP is unknown, press the Scan Network button to search for and add
the gateway.
Device Settings - The touch pad can be renamed for easier syncing with Velocity. Type the
name into the Alias eld.
Touch Screen LAN Conguration - The current IP settings will display in these elds. To
switch to a static IP, select the Set Static IP slider, ll in the IP information, and press Save.
Set PIN - The default PIN of 554361 can be changed to a new pin by pressing the Set PIN
button. Type the new PIN in and press Save PIN.
Clear Cache - Press the Clear Cache button to release the current cache of the VSP. Press
the OK button to verify.
Factory Reset - Press the Factory Reset button to clear all the settings and start the touch
pad set up again. Press the OK button to verify.

Installation Guide
AT-VSP-800-BL and AT-VSP-800-WH
7
Troubleshooting
Problem Cause Solution
My touchpad won’t power
on.
The touchpad is not
connected to a PoE switch.
• Connect the touchpad to a
switch that supports 802.3at
PoE.
• If a PoE switch is not
available, use a PoE injector
(sold separately) to power
the unit.
My touchpad isn’t receiving
an IP address.
The connected network is
not DHCP enabled.
• Swipe from the left corner
to the right and press
the refresh button. It can
sometimes take up to 60
seconds to obtain an IP
address.
• Set the touchpad to static IP
by selecting the Set Static
IP slider and providing IP,
subnet, gateway, and DNS
server information.

Installation Guide
AT-VSP-800-BL and AT-VSP-800-WH
8
Version 1
© 2020 Atlona Inc. All rights reserved. “Atlona” and the Atlona logo are registered trademarks of Atlona Inc. All other brand names and trademarks or registered
trademarks are the property of their respective owners. Pricing, specications and availability subject to change without notice. Actual products, product images, and
online product images may vary from images shown here.
Toll free US International
atlona.com •877.536.3976 •41.43.508.4321
This manual suits for next models
1
Table of contents
Other Atlona Touch Panel manuals