Atop IJG7001 Series Manual

Industrial PoE Injector with DC voltage booster
IJG7001 Series
Version 1.0
Updated in October, 2019
P/N : 89900568G
Inside the package you will find the following items:
■ Inject x 1
■ Installation Guide with Warranty Card x 1
Front View
IJG7001
Never install or work on electrical or cabling during periods of lightning activity.
Never connect or disconnect power when hazardous gases are present.
Warning:Hot Surface Do Not Touch. RESTRICTED ACCESS AREA: The equipment
should only be installed in a Restricted Access Area.
IndoorIndoor
This equipment should be installed indoor and not connect directly with equipment
installed outdoor.
1. PWR1 LED
2. PWR2 LED
3. PoE LED
4. 10/100/1000 BASE-T(X) RJ45 Port
5. 10/100/1000 BASE-T(X) RJ45 PoE RJ-45 Port
6. DIP Switch
1. Grounding Screw
2. Terminal for Power 2
3. Terminal for Power 1
4. Frame Ground
P1 P2
PoE
PoE outData in
123654
1
2
3
4
V2+
V1+
F.G.
1
2
1
2
You can then choose whether to plug in the other peripheral ports at this point
or do it later depending on the actual location of the device or level of comfort
for performing such operation.
3.
Once the plate has been firmly put in place, proceed to mount the whole
device as shown in (Fig. 3).Proceed to (Fig. 4) if you want to remove the
device from DIN-Rail.
4.
Next we can then proceed to connect
the device to the LAN (switch or PC,
depending on the case), take care on
using the RJ-45 connector; after this
we can then proceed to the device’s
settings
5.
If you have purchased the wall mount kit,
proceed to place the screws on the back
of the device as show in (Fig. 1).
1.
2. Although internal grounding has been
done inside, in order to ensure overall
maximum performance and protect your
device, it is still strongly advised to ground
the device properly; hazardous ESD can
come into contact and damage your
equipment. On the power terminal block,
there is a terminal for Frame Ground, you
can choose whether to connect it to the
grounding or you may opt to connect to
the grounding screw next to the terminal
block ( the one chosen should be connect-
ed at all times ) (Fig. 2)
■ The opening to the sides are for the
device’s heat dissipation please never
obstruct or cover them with any
objects or try to insert them through it.
V2+
V1+
F.G.
V2+
V1+
F.G.

Color State
LED Description
Green
On
Off
On
Off
Power is being supplied through this power input
Power is not supplied through this power input
PoE Device Link
No PoE Device Detected
P1
P2
PoE Green
Power input : 12~57 VDC, 1.7A Max (For 802.3af)
12~57 VDC, 3.6A Max (For 802.3at)
PoE (Mode A)
1000BASE-T
10/100BASE-T(X)
DC V+ V+ V- V-
PoE (Mode B)
DC V+ V+ V- V-
SettingDIP Switch Description
Mode A(On)
Mode B(Off)
1
2
The device provides power via data
pair (pins 1, 2, 3, and 6).
The device provides power via spare
pair (pins 4, 5, 7, and 8).
Reserved for future use.
DIP Switch
If the device requires servicing of any kind, you may need to disconnect and
remove it from its mounting. The initial installation should be done in a way that
makes this as convenient as possible.
■ Voltage/Power lines should be properly insulated as well as other cables. Be
careful when handing the so as to not trip over
■ Do not under any circumstance insert foreign objects of any kind into the heat
dissipation holes located in the different faces of the device. This may not only
harm the internal layout but might cause harm to you as well.
■ Do not under any circumstance open the device for any reason. Please
contact your dealer for any repair needed or follow the instructions on section
of your User’s Manual.
Field Maintenance and Service
Top View
Side View Rear View
Bottom View
Front View
124.4
34
31.5
18.5
112
98
48.3 108.8 136.4
34
124.4112
34 34
98
Customers shall always obtain an authorized "RMA" number from Atop before
shipping the goods to be repaired to Atop. When in normal use, a sold product
shall be replaced with a new one within 3 months after purchase. The shipping
cost from the customer to Atop will be reimbursed by Atop.
After 3 months and still within the warranty period, it is up to Atop whether to
replace the unit with a new one; normally, as long as a product is under warranty,
all parts and labor are free of charge to the customers.
After the warranty period, the customer shall cover the cost for parts and
labor.Three months after purchase, the shipping cost from the customer to Atop
will not be reimbursed, but the shipping cost from Atop to the customer will be
paid by Atop.
Atop shall not be held responsible for any consequential losses from using Atop’s
product.
Warranty Policy
The warranty certification will not be effective until an authorized stamp issued by
Atop’s overseas agents.
Purchase Date: / / (yyyy/mm/dd)
Serial Number
Product CategoriesWarranty WarrantyProduct Categories
Media Converters
Embedded Device Servers
PoE Injectors
Ethernet Switches
Wireless
Serial Device Servers
Modbus Gateways
DIN-Rail Power Supplies
Power Adaptors
Antennas
Other Accessories
Warranty Conditions
RMA and Shipping Costs Reimbursement
Limited Liability
1. Please contact your local dealers or Atop Technical Support Center at the
following numbers.
+ 886-3-550-8137 (Atop Taiwan)
+ 86-21-6495-6232 (Atop China)
2. Please report the defected problems via Atop’s Web site or E-mail account
Web Site:www.atop.com.tw, e-mail:[email protected]
Web Site:www.atop.com.cn, e-mail:[email protected]
Atop Customer Services and Supports
Products supplied by Atop Technologies are covered in this warranty for
sub-standard performance or defective workmanship. The warranty is not,
however, extended to goods damaged in the following circumstances:
(a) Excessive forces or impacts
(b) War or an Act of God: wind storm, fire, flood, electric shock, earthquake
(c) Use of unqualified power supply, connectors, or unauthorized parts/kits
(d) Replacement with unauthorized parts
Warranty Period
─ Any changes to this material will be announced on Atop website. ─
Other Atop Laboratory Equipment manuals
Popular Laboratory Equipment manuals by other brands

Orphee
Orphee Mythic 18 Vet Operator's manual

Biocontrol
Biocontrol LIGHTNING MVP ICON manual

PerkinElmer
PerkinElmer Panthera-Puncher 9 user manual

Priorclave
Priorclave Q63 Operation & maintenance manual

MPW MED. INSTRUMENTS
MPW MED. INSTRUMENTS MPW M-BASIC user manual

IKA
IKA C 6000 global standards operating instructions