Attract EMT-1040 Manual

1
EMT-1040 Maintenance Service Manual
I. Trouble catalog
Common Trouble and processing Methods are listed as follow:
Serial NO.
Phenomenon
Description
Maintenance Methods
01
No Function
When Starting.
The LCD isn’t illuminating:
①Fuse melts (in the Power Source Box or
on the main PCB).
②Power supply circuit poorly connected.
③EMC Board fails.
④main PCB fails.
①Replace Fuse.
②Replace Power Box.
③Replace EMC Board.
④Replace main PCB.
02
No function when
starting.
The LCD is illuminating:
①Mechanical switch fails or it’s wire is
opened.
②Up or Down Stroke Photoelectricity
fails.
③Main PCB fails.
④Kneading is on without pressing any
key when starting and no response by
pressing other keys.
①Replace mechanical switch or it's
wire.
②Replace Stroke Photoelecruicity.
③Replace the main PCB.
④Width Inspection Board of PCB
fails, replace it.
03
No Width
switchover.
①The terminals of Width Inspection on
main PCB and wires are poorly connected.
②The terminals of Width Inspection on
massage mechanical and wires are poorly
connected.
③Width Inspection fails.
④Main PCB fails.
①&②Plug the terminal securely or
replace the wires.
③Replace Width Inspection.
④Replace the main PCB.

2
04
No Partial
Function.
①Height Inspection Terminal or Wire
Poorly Contacts.
②Height Counting Subassembly fails.
③Photoelectricity Subassembly fails.
①Plug the terminal securely or
replace the wires.
②Replace Height Counting Sub
-assembly.
③Replace Photoelectricity Sub
-assembly.
05
No Rolling.
①Terminal or Wire Poorly Contacts.
②Down-stroke Photoelectrictity
Subassembly Fails.
③Up-stroke Photoelectrictity
Subassembly Fails.
④Rolling Motor Fails.
⑤Main PCB Fails.
①Plug the terminal securely or
replace the wires.
②Replace Down-Stroke Sub
-assembly.
③Replace Up-Stroke Subassembly.
④Replace Rolling Motor.
⑤Replace main PCB.
06
No kneading.
①The terminals on main PCB and wires
are poorly connected.
②Kneading motor fails.
③Main PCB fails.
①Plug the terminal securely or
replace the wires.
②Replace the kneading motor.
③Replace main PCB.
07
No tapping.
①The terminals on main PCB and wires
are poorly connected.
②Tapping motor fails.
③Main PCB fails.
①Plug the terminal securely.
②Replace the tapping motor.
③Replace main PCB.
08
No response
when pressing the
keys on the
remote controller.
①The terminals and wires are poorly
connected.
②the PCB in the remote controller fails.
①Plug the terminal securely or
replace the wires.
②replace the remote controller.
09
Backrest cannot
recline or sit up.
①the terminal of electrically operated
pusher and wires are poorly connected.
②the electrically operated pusher fails.
③main PCB fails.
①Plug the terminal securely.
②replace the electrically operated
pusher.
③replace main PCB.

3
10
The Foot Rest
cannot lift or
recline.
①the terminal of electrically operated
pusher and wires are poorly connected..
②the electrically operated pusher fails.
③main PCB fails.
①Plug the terminal securely.
②replace the electrically operated
pusher.
③replace main PCB.
11
No vibration by
the motors in the
seat-pad.
①Print motors fail.
②The terminals and wires are poorly
connected or the wires fail.
③Main PCB fails.
①Replace the print motor.
②Plug the terminal securely or
replace the wires.
③Replace main PCB.
12
No vibration by
the motors in the
Foot Rest.
①Print motors fail.
②The terminals and wires are poorly
connected or the wires fail.
③Main PCB fails
①Replace the print motor.
②Plug the terminal securely or
replace the wires.
③Replace main PCB.
13
No gas charging
in the seat-pad.
①The terminal of the snuffle valves and
wires are poorly connected.
②The snuffle valves fail.
③The inflator pump fails.
④Main PCB fails.
①Plug the terminal securely.
②Replace the snuffle valves.
③Replace the inflator pump.
④Replace main PCB.
14
No gas charging
in the Foot Rest.
①The terminal of the snuffle valves and
wires are poorly connected.
②The snuffle valves fail.
③The inflator pump fails.
④Main PCB fails.
①Plug the terminal securely.
②Replace the snuffle valves.
③Replace the inflator pump.
④Replace main PCB.

4
II.Troubleshooting Process
Notes for repairing chair or replacing parts:
①Make sure the power is OFF before tearing down the wires, moving terminals or replacing parts.
②Semiconductors (such as IC and others) are very easy to be damaged by static, so when you touch
the PCB, please make sure your body is grounding (by wearing a girding static ring), or your hands
are touching with earthing grip (household electrical appliances putting to earth, such as fridges,
washers and so on) to release all static of the body.
1. No function when starting.
N Y
Y N
N Y
否
是
N
Y
Y Y
N
N
N
Y
否
N
Is the LCD illuminating?
Is the fuse melted?
Replace fuse.
Are the terminals of
Up and Down
Stroke Subassembly
connected securely?
Stroke subassembly
connect securely or not
Is the power cord
open-circuit?
The switches of Up and
Down Stroke Subassembly
fail or not?
The EMC Board fails
or not
Replace power cord.
Replace it.
Connect
securely.
Replace them.
Is kneading on without pressing
any key when starting?
Width Inspection
Board fails or not?
Replace main PCB.
Replace Width Inspection
Board.

5
2. No width switchover.
N
Y
Y
N
3. No function(fixed-spot or partial).
N
Y
Y
N
5. No kneading.
N
Y
Y
N
Y
N
Are the terminals of Width Inspection Board and
main PCB connected securely?
Connect securely.
Width Inspection Board fails or not?
Replace it.
Replace main PCB.
Are the terminals of Height Inspection
Board and main PCB connected securely?
Connect securely.
Height Inspection Subassembly fails or not?
Replace it.
Replace Main PCB.
Are the terminals of kneading motor wire and
main PCB connected securely?
Connect securely.
Kneading motor fails or not?
Width Inspection Board fails or not?
Replace main PCB.
Replace the motor.
Replace it.

6
6. No tapping.
N
Y
Y
N
7. Remote controller doesn’t work.
N
Y Y
N
8. Electrically operated pusher doesn’t work.
N N
Y Y
Y Y
N N
Are the terminals of tapping motor wire and main
PCB connected securely?
Connect securely.
Tapping motor fails or not?
Replace the motor.
Replace main PCB.
Are the terminals of remote controller wire and
main PCB connected securely?
Connect securely.
The conductive rubber fails or not?
Replace it.
Replace the remote controller.
Are the terminals of
electrically operated pusher
for backrest and main PCB
connected securely?
Connect
securely.
Are the terminals of
electrically operated pusher
for Foot Rest and main
PCB connected securely?
Connect
securely.
The electrically operated
pusher fails or not?
Replace it.
The electrically operated
pusher fails or not?
Replace it.
Replace main PCB.

7
9. No vibration.
N N
Y Y
否N N
Y Y
Y Y
N N
10. No gas charging.
N N
Y Y
Y Y
N N
N N
Y Y
YY
N N
Common trouble about electric control and processing methods of EC-587C are mentioned above. It is for
indication only. (Maintenance and repair guide is additional.)
Are the terminals of print motors
in the seat pad and main PCB
connected securely?
Are the connectors in the middle
of the wire connected securely?
Are the terminals of print
motors in the calves-rest
and main PCB connected
securely?
Are the connectors in the middle
of the wire connected securely?
检查小腿振动电机对插线是否连
接好
Replace main PCB.
Connect
securely.
Connect
securely.
Print motor fails or not?
Print motor fails or not?
Replace it.
Replace it
Connect
securely.
Connect
securely.
Are the terminals of snuffle valve
for bags in the seat pad and main
PCB connected securely?
Snuffle valve fails or not
Are the terminals of snuffle valve
for bags in the Foot Rest and main
PCB connected securely?
Snuffle valve fails or not?
Connect
securely.
Connect
securely.
Are the terminals of inflator
pump and main PCB
connected securely?
Replace it.
Replace it.
Air pump
Replace it.
Replace it.
Valve
Are the terminals of inflator
pump and main PCB
connected securely?
Connect
securely.
Connect
securely.
Inflator pump fails or not?
Inflator pump fails or not?
Replace main PCB.

8
III.Terminals on the main PCB
Terminal of Height
Inspection.
8VAC voltage output
terminal.
Terminal of inflator
pump.
Terminal of Up and Down
Stroke Photoelectricity.
Terminal of rolling ,
kneading and tapping
motors.
Terminal of ionizer
and heater winding.
12VAC voltage
input terminal.
Terminal of Body
Inspection.
10.5VAC voltage
input terminal.
Terminal of vibration
motors.
Terminal of snuffle
valves.
Terminal of electrically operated
pusher of the Foot Rest.
Terminal of electrically operated
pusher of backrest.
20.5VAC voltage input
terminal.
110VAC voltage
output terminal.
Terminal of remote controller.
Terminal of width inspection.

9
Please make sure the massage chair is POWER OFF before maintenance and
repair. As the voltage specification is 110~130VAC, please make sure the plug is
removed from outlet for safety before processing operations as follow.
IV. Maintenance of the Backrest
1: Disassemble the Back Pad
A:You can find a zip of the Back Pad on the top of the Backrest.
B:Unzip, then the Back Pad can be removed.
C:If it’s damaged, a new one should be replaced.
Note: Proceed in the reverse order of disassembly when replacing a new one.
2:Disassemble or replace the rear cover of the Backrest
If disfiguring damage or crack happened,
or the cloth is damaged, you can proceed as follow:
A: Find 4 pieces screws on the rear cover.
B: Drive them with a plus screwdriver.
C: Then remove the rear cover.
D: If it’s damaged, a new one should be replaced.
Note: Take care not to damage the rear cover to
avoid bad external appearance. Proceed in the reverse order of
disassembly when assembling the rear cover.
Tool: a plus screwdriver
(1)Zip of the Back Pad
(2)Plus screws(4pcs)
M5×20
(3)The rear cover, screws
and plus screwdriver

10
3:Disassemble or replace the front cover of the Backrest
If disfiguring damage or crack happened, or the inside
cloth is damaged, you can proceed as follow:
A:After disassembling the rear cover, you can find 5 pieces of screws
fastening the front cover to the metallic frame of the Backrest.
B:Drive the screws with a plus screwdriver.
C:Then remove the front cover.
D:You should proceed in the reverse order of above
if replacement needed.
★Tool: a plus screwdriver
Note: There are 5 pieces of plastic block
between the front cover and metallic part.
4:Disassemble the EMC of motor:
4.1. Disassemble and replace the EMC of kneading
or tapping motor
A:Disassemble the rear cover of the Backrest as mentioned above.
B:You can find the EMC boxes in the bottom of the
massage mechanism.
C:Cut the cable ties with a wire cutter.
D:Drive the screws fixing the upper cover to the lower
cover of the EMC box with a plus screwdriver.
E:If the box is damaged, drive the screws fixing the PCB of EMC
and lower cover to the sheet-metal. Then replace the box and tighten the
screws.
Size and amount:
Top: 6×35(1pcs)
Middle: 4.8×40(2pcs)
Bottom:4.8×35(2pcs)
(6)Size and amount:
Upper cover: 2.9×8(4pcs)
Lower cover: 3.5×10(2pcs)
3.5×18(2pcs)
(4)The top screw
(5)The bottom screws

11
F:If the PCB fails, cut the wire connect to the PCB and place a new one.
Then tie the wires and tighten them with contact nipples. Tighten all the
screws in the right place.At last, fix the wires with the cable ties.
Tool: a plus screwdriver
Note: The two EMC boxes are on and below the sheet-metal,
And the PCB and lower cover are fixed to the sheet-metal
with two screws each side.
4.2. Disassemble and replace the EMC of rolling motor
A:Disassemble the rear cover of the Backrest, then find the EMC
box at the bottom of the Backrest frame.
B:Drive the screws at the corner of the box with a plus
screwdriver, then the upper cover can be moved.
C:There are 2 pieces of screws fixing the PCB of EMC and
the lower cover on the sheet-metal. Drive them with a plus screwdriver.
(9)Screws fixing the upper and lower
cover 2.9×8(4pcs)
(10)Screws fixing the PCB of EMC
and the lower cover on the sheet-metal
(8)The boxes of EMC ,screws
and plus screwdriver
(7)Screws fixing the PCB of EMC
and lower cover to the sheet-metal

12
D:If the PCB fails, cut the wire connect to the PCB, replace a
new one, then tighten the screws and fix the wires with cable ties.
5:Disassemble kneading, tapping and rolling motors
The voltage of this massage chair is high and the motors are rotating in high speed, so
make sure the power is OFF before disassembly. For safety, you should remove plug from outlet.
Note:Disassemble the rear cover of the Backrest only, before disassembling the motors.
5.1 Kneading motor(DC -120V):
A:Disassemble the rear cover of the Backrest, and find the belt
at top of the massage mechanism, then loosen the belt as shown in the picture.
B: Find the wire of kneading motor, and cut the cable ties
tightening the wire with wire cutters. Move the contact nipple
covering the wires with a nipper pliers, then disconnect the two wires.
C: Find 3 pieces of screws tightening the kneading
motor to the sheet-metal, drive the screws with a plus screwdriver, you should
replace a new one if it does work..
(12)Loosened belt
(13)Drive screws
M6×8(3pcs)
(11)Remove the PCB of EMC

13
F: Proceed in the reverse order of disassembly when replacing a new one.
Tools: aplus screwdriver, nipper pliers, wire cutters
5.2Rolling motor(DC -120V):
A :Press the barb of the Backrest and put the Backrest forward
to Seat Pad for disassembling the motor easily.
B:The rolling motor is at the bottom of backrest (Picture 17),
There is a belt between two belt wheels below the
sheet-metal as shown in the figure 18. Loosen the belt carefully.
C :Cut the cable ties tightening the wire of the rolling motor.
D :Remove the nipple covering the wires with a nipper pliers,
then disconnect the two wires.
E :Drive the screws tightening the rolling motor to the sheet-metal
with a plus screwdriver.
(14)Hold the motor to
avoid dropping when
driving the screws
(16)The barb of the Backrest
(18)Loosened the
belt for rolling motor
(17)The rolling motor
(15)Tools needed

14
F :Then the motor can be removed, replace a new one if needed.
G :Proceed in the reverse order of disassembly when replacing a new one.
Tools: a plus screwdriver, nipper pliers, wire cutters
5.3 Tapping motor(DC -120V):
Just disassemble the rear cover of the Backrest before disassembling the tapping motor.
A: Find the wire of tapping motor, cut the cable
ties tightening thewire of motor with wire cutters.
B: Remove the nipple covering the wires with
a nipper pliers,then disconnect the two wires.
C: Disassemble the left side swinging arm (reference the
disassembly of swinging arms), then loosen the belt,
drive the screws tightening the tapping motor to the sheet-metal.
D: The motor can be removed after driving the screws, a new one can be replaced if needed.
E: Proceed in the reverse order of disassembly when replacing a new motor.
Always remember to tighten the screws first, then the belt.
Tools: a plus screwdriver, nipper pliers, wire cutters
(19)Driving the screws
M5×16 (3 pcs)
(20)The massage mechanism
without the left swinging arm.
(21)Loosen the belt, and drive the screws
tightening the tapping motor to the sheet-metal.
(22)Tapping motor

15
Note: You don’t have to disassemble the left swinging arm before disassembling
the tapping motor. But it is not easy to drive the screws. So take care not to
damage the screw caps.
6:Disassemble and repair the massage mechanism
Note: You should disassemble the rear and front cover of the Backrest, before disassembling the massage
mechanism.
6.1 Disassemble the massage mechanism:
A: Disassemble the rear and front covers, cut all the cable ties tightening the wires and put the wires in order.
B: Remove the nipples tightening the wires of kneading and tapping motors with pliers, then disconnect the wires.
C: Pull out the terminal of width inspection board.
D: Loosen the belt of the kneading motor, drive the 4 pieces of
screws fixing the massage mechanism to the frame with
inner hexagon spanner(5mm).
E: You may not get it out because of the screw bolt. So rotate the
big belt wheel to adjust the width of swinging arms until you can
get it out easily.
Tools: a plus screwdriver, inner hexagon spanner(5mm), pliers, wire cutters
6.2 Disassemble the swinging arms and universal rods:
Note: You don’t have to disassemble the massage mechanism before
disassembling the swinging arms.
A: Drive the hexagon check nut tightening the swinging arm
to eccentric shaft with a hexagonal socket wrench(1/2).
B: Remove the hexagon check nut and washer.
(23 )Drive the screws without
disassembling the left swinging arm.
(24)Drive the screws fixing the
massage mechanism to the frame with
inner hexagon spanner(5mm).
screws fixing the massage
mechanism to the frame with
inner hexagon spanner(5mm).
(25)Drive the hexagon check nut

16
C: Drive the hexagon check nut tightening the universal rod assembly
to eccentric shaft with a hexagonal socket wrench(1/2).
D: Remove the hexagon check nut and washer, so you can separate
the swinging arm and universal rod from the massage mechanism.
E: Remove the tension spring, and further disassembly can be done.
Tool: hexagonal socket wrench(1/2)
Note:When driving the hexagon check nut tightening the universal
rod assembly to eccentric shaft, you can’t loosen it for the rotating shaft.
So the eccentric shaft should be fixed. What you should do is inserting
an iron rod into the hole of the shaft to stop its rotating.
6.3 Disassemble the universal rod:
A: Drive the screws tightening the plastic cover
to the winging arm with a plus screwdriver
if any parts need replacing.
B:Remove the plastic cover, so you can separate
the universal rod form the winging arm.
C: Drive the screw bolt tightening the flat end to
the plastic bearing block with a shifting spanner
and a plus screwdriver.(As is shown in the picture 30.)
Tools: shifting spanner(7mm), a plus screwdriver.
(26)Remove the hexagon check nut
(28)Drive the
screws
(30)Drive the screw bolt
(27)Parts taken down and tool
(29)Parts taken
down

17
6.4 Replace the optocoupler of body type checkout
Note: You just disassemble the rear and front covers of the Backrest before disassembling the optocoupler of body type
checkout.
A: Drive the screw tightening the optocoupler
to the swinging arm with a plus screwdriver
B: Disassemble the optocoupler on the other swinging
arm in the same way. Now you can replace it.
C: You can disassemble the optocouplers in the way
mentioned above if the wires need replacing.
Tool: a plus screwdriver
6.5 Replace the shock pad
A: Find the screw tightening the shock pad to the swinging arm.
B: Drive the screw with a plus screwdriver, so you can replace it.
C: Proceed in the reverse order of disassembly when replacing a new one.
Tool: a plus screwdriver
6.6 Disassemble the holder of roller wheels
A: It is unnecessary to disassemble the massage mechanism to
replace the holder of roller wheels,
just disassemble the rear cover of the Backrest.
B:Drive the screw bolt tightening the holder to
the swinging arm with a hexagonal socket wrench (10 mm)
and a minus screwdriver. (As is shown in the picture 33.)
Pull the screw bolt out, and the holder can be removed.
(33)Disassemble the
holder of roller wheels
(31)Drive the screws
(32 )Drive the screw
tightening the shock pad

18
C:Remove the tension spring and a new holder can be replaced if needed.
D:Proceed in the reverse order of disassembly when replacing a new one.
Tools:hexagonal socket wrench (10 mm), a minus screwdriver
6.7 Disassemble and replace the roller wheels
A: Disassemble the rear cover of the Backrest.
B: Drive the hexagon check nut tightening the roller wheel
to the holder with a hexagonal socket wrench(1/2).
C: Replace a new roller wheel and tighten the hexagon check nut.
Tool: a hexagonal socket wrench (1/2)
Note: There is a plastic washer between the wheel and the nut.
6.8 Disassemble width inspection board
A: Disassemble the rear and front covers of the Backrest.
B:Pull out the terminal of width inspection board.
C:Disassemble the left swinging arm as mentioned in 6.2.
D:Drive the screw bolt tightening the light barrier to
the eccentric shaft with shifting spanner and inner
hexagon spanner, then the eccentric shaft can be removed.
E: Drive the screws tightening the width inspection
board to the reduction gear box with a plus screwdriver.
(34)Disassemble the roller wheel
(35)Drive the screw bolts and nuts
(36)Nuts, screw bolts, light
barrier and eccentric shaft

19
F: Proceed in the reverse order of disassembly if the
width inspection board or light barrier needs replaced.
Tools: plus screwdriver, shifting spanner, inner hexagon spanner(3mm)
Note:In order to operate conveniently, you can
disassemble the massage mechanism first,
then disassemble the width inspection board.
7.Disassemble the Photoelectricity Subassembly :
7.1. Disassemble and replace Up and Down Stroke Photoelectricity Subassembly :
A:Disassemble the rear cover of the Backrest. Drive the screw bolts
tightening the PCB of up or down stroke photoelectricity subassembly
to the sheet-metal with a plus screwdriver and nipper pliers.
B: Pull out the terminal of the wire, then you can replace a new one.
C: Proceed in the reverse order of disassembly if replacement needed.
Tools: a plus screwdriver and nipper pliers
Note: Generally speaking, the Stroke Photoelectricity
Subassembly is so stabile that it can’t be damaged easily.
7.2 Disassemble and replace the counting Photoelectricity Subassembly
A:Disassemble the rear cover of the Backrest. Cut the cable ties
tightening the wire.
B:Pull out the terminal of the wire, then drive the screws with a plus screwdriver.
C:Then the PCB of the counting Photoelectricity Subassembly can be replaced.
D:Proceed in the reverse order of disassembly if replacement needed.
Tool: a plus screwdriver
(38)The width inspection
board and a plus screwdriver
(41)Pull out the terminal
and driver the screws
(39)Screw blots tightening
the PCB(3pcs)M3×16
(40)Terminal
of the wire
(37 )Drive the screws
tightening the board

20
8. Disassemble and replace bearings and bearing blocks
A:Disassemble the rear and front covers of the Backrest.
B:Drive the screw bolts tightening the bearing block
to the sheet-metal with a plus screwdriver and shifting spanner.
C:Drive the screws tightening the sheet-metal to
the frame with a plus screwdriver.
D:Remove the sheet-metal, so you can pull out
the bearing block. Turn the block clockwise and
counterclockwise alternately to pull it out easily.
Tools: a plus screwdriver, shifting spanner.
(42)Drive the screw bolts tightening
the block(3pcs)M4.8×16
(43)Drive the screws tightening
the sheet-metal to the frame
M5×20
(44)Pull out the
bearing block
Table of contents