AUDAC ANM88 User manual

Hardware Manual
ANM88
audac.eu

ANM88 - Quick Start Manual ANM88 - Quick Start Manual02
ADDITIONAL INFORMATION
This manual is put together with much care, and is as complete as could be on the publication date.
However, updates on the specications, functionality or software may have occurred since publication.
To obtain the latest version of both manual and software, please visit the Audac website @ audac.eu.

ANM88 - Quick Start Manual 03
Table of contents
Introduction 05
Dante™/AES67 networked audio module with 8x8 license for LUNA-U . . . . . . . . . . . . . . . . . . . . . . 05
Precautions 06
Chapter 1 08
Network settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 08
Chapter 2 09
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 09
Updating the system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Technical specications 13
Notes 14

ANM88 - Quick Start Manual ANM88 - Quick Start Manual04

ANM88 - Quick Start Manual 05
Introduction
The ANM88 is a hardware extension card that makes a LUNA-U audio matrix processor a Dante™/AES67
enabled device. It comes with 8x8 Dante™/AES67 channels and can be expanded with additional
software extension SL-NAC8 for additional networked audio channels. The LUNA-U is limited to a
maximum of 32x32 channels.
Dante™/AES67 networked audio module with 8x8 license
for LUNA-U

ANM88 - Quick Start Manual ANM88 - Quick Start Manual06
Precautions
READ FOLLOWING INSTRUCTIONS FOR YOUR OWN SAFETY
ALWAYS KEEP THESE INSTRUCTIONS. NEVER THROW THEM AWAY
ALWAYS HANDLE THIS UNIT WITH CARE
HEED ALL WARNINGS
FOLLOW ALL INSTRUCTIONS
NEVER EXPOSE THIS EQUIPMENT TO RAIN, MOISTURE, ANY DRIPPING OR SPLASHING LIQUID. AND NEVER PLACE AN
OBJECT FILLED WITH LIQUID ON TOP OF THIS DEVICE
NO NAKED FLAME SOURCES, SUCH AS LIGHTED CANDLES, SHOULD BE PLACED ON THE APPARATUS
DO NOT PLACE THIS UNIT IN AN ENCLOSED ENVIRONMENT SUCH AS A BOOKSHELF OR CLOSET. ENSURE THERE IS
ADEQUATE VENTILATION TO COOL THE UNIT. DO NOT BLOCK THE VENTILATION OPENINGS.
DO NOT STICK ANY OBJECTS THROUGH THE VENTILATION OPENINGS.
DO NOT INSTALL THIS UNIT NEAR ANY HEAT SOURCES SUCH AS RADIATORS OR OTHER APPARATUS THAT PRODUCE
HEAT
DO NOT PLACE THIS UNIT IN ENVIRONMENTS WHICH CONTAIN HIGH LEVELS OF DUST, HEAT, MOISTURE OR VIBRATION
THIS UNIT IS DEVELOPED FOR INDOOR USE ONLY. DO NOT USE IT OUTDOORS
PLACE THE UNIT ON A STABLE BASE OR MOUNT IT IN A STABLE RACK
ONLY USE ATTACHMENTS & ACCESSORIES SPECIFIED BY THE MANUFACTURER
USE THE APPARATUS ONLY IN MODERATE CLIMATES
CAUTION - SERVICING
This product contains no user serviceable parts. Refer all servicing to qualied service
personnel. Do not perform any servicing (unless you are qualied to)
EC DECLARATION OF CONFORMITY
This product conforms to all the essential requirements and further relevant
specications described in following directives: 2014/30/EU (EMC) & 2014/35/EU (LVD).
WASTE ELECTRICAL AND ELECTRONIC EQUIPMENT (WEEE)
The WEEE marking indicates that this product should not be disposed with regular
household waste at the end of its life cycle. This regulation is created to prevent any
possible harm to the environment or human health.
This product is developed and manufactured with high quality materials and
components which can be recycled and/or reused. Please dispose this product at
your local collection point or recycling centre for electrical and electronic waste. This
will make sure that it will be recycled in an environmentally friendly manner, and will
help to protect the environment in which we all live.

ANM88 - Quick Start Manual 07

ANM88 - Quick Start Manual ANM88 - Quick Start Manual08
Chapter 1
Network settings
STANDARD NETWORK SETTINGS
DHCP: ON
IP Address: Depending on DHCP
Subnet Mask: 255.255.255.0 (Depending on DHCP)
Gateway: 192.168.0.253 (Depending on DHCP)
DNS 1: 8.8.4.4 (Depending on DHCP)
DNS 2: 8.8.8.8 (Depending on DHCP)

ANM88 - Quick Start Manual 09
Chapter 2
CAUTION
Before installing the Dante Brooklyn 3 module to LUNA-U, make sure the power is switched off.
Malfunctions or electrical shocks may occur otherwise.
Step 1:
Make sure that the slot whereto the module should be installed is open and ready for installation. The
corresponding slot can be reached by releasing the four screws on the cover panel located on top of
the LUNA-U.

ANM88 - Quick Start Manual ANM88 - Quick Start Manual010
Step 2:
Before removing the module from its protective box, we recommend touching a grounded metal
chassis (or any other grounded point) and during the installation wearing a grounded EAS wristband
to prevent electrostatic discharges affecting the sensitive electronic components. It is recommended
to always hold the module card by the metal connection panel and avoid touching the components
on the circuit board directly.
Step 3:
Align both edges of the module with the slot and carefully insert the module into the slot. It should slide
into the slot without any considerable resistance when well positioned into the guide rail.

ANM88 - Quick Start Manual 011
Step 4:
Fasten the cover panel using the four screws. Once the module is installed into the slot correctly, the
system can be powered-on and the module functionality will be automatically discovered.

ANM88 - Quick Start Manual ANM88 - Quick Start Manual012
Updating the system
The update section on the front overview screen shows the running version of the device and the updates
which are available. Thanks to the OTA feature of the LUNA series, the device automatically checks the
latest version whenever the device is on the network. On this screen, the device can be updated to
available software by holding the rotary function dial for 5 seconds.

ANM88 - Quick Start Manual 013
Technical specications
Dante Brooklyn 3
Module
Network audio I/O 8x8 Dante™/AES67 I/O Channels
(Up to 32x32 Channels with SL-NAC8)
Audio Transport Formats Dante Audio over IP, AES67 RTP, SMPTE
ST2110-30 RTP (enrolled devices)
Sample Bit Depth 16, 24 or 32 bits per sample
Audio Buffering Up to 2000 samples per channel
Clocking Onboard word clock or external word
clock
Dimensions (W x D) 45 x 60 mm
Power 3.3VDC @ 2W max
Physical Connector Mini-PCI
Compatible device LUNA-U

ANM88 - Quick Start Manual ANM88 - Quick Start Manual014
Notes

ANM88 - Quick Start Manual 015
Notes

Discover more on audac.eu
Other AUDAC Computer Hardware manuals
Popular Computer Hardware manuals by other brands

Chargery
Chargery BMS8T Series manual

Phanteks
Phanteks GLACIER ONE D30 installation guide

Texas Instruments
Texas Instruments controlCARD TMDSCNCD2800137 user guide

Conrad
Conrad J5CREATE JUA230 operating instructions

Infineon Technologies
Infineon Technologies CPU-13A-V1 user manual

Nvidia
Nvidia RTX 6000 quick start guide